FDA Adverse Event Malfunction Summary report: N

CHANNEL DRAIN

MDR report key: 20694343 · Received November 15, 2024

Report

Report Number
1018233-2024-07250
Event Type
Malfunction
Date Received
November 15, 2024
Date of Event
October 23, 2024
Report Date
February 6, 2025
Manufacturer
C.R. BARD INC. (COVINGTON) -1018233
Product Code
GBX
UDI-DI
00801741119194
PMA / PMN Number
EXEMPT
Product Problem
Yes
Report Source
Manufacturer report
Reporter Location
LA, US
Reporter Occupation
OTHER HEALTH CARE PROFESSIONAL
Health Professional
Yes

Narratives

Additional Manufacturer Narrative · 0

THE INVESTIGATION IS STILL IN PROGRESS. ONCE THE INVESTIGATION IS COMPLETE A SUPPLEMENTAL REPORT WILL BE FILED. UDI FORMAT UPDATED WITH AVAILABLE PRODUCT INFORMATION PER GUDID. H11: SECTION A THROUGH F - THE INFORMATION PROVIDED BY BD REPRESENTS ALL THE KNOWN INFORMATION AT THIS TIME. DESPITE GOOD FAITH EFFORTS TO OBTAIN ADDITIONAL INFORMATION, THE COMPLAINANT / REPORTER WAS UNABLE OR UNWILLING TO PROVIDE ANY FURTHER PATIENT, PRODUCT, OR PROCEDURAL DETAILS TO BD.

Additional Manufacturer Narrative · 0

THE REPORTED EVENT IS CONFIRMED AS MANUFACTURING RELATED. FIVE PHOTOS WERE RECEIVED FOR EVALUATION. THE FIRST ONE SHOWS A PILE OF 7 BOXES. THE SECOND PHOTO SHOWS THE LABEL ON THE BOX EVIDENCING CAT NO: V072229 15FRROUND HUBBLESS AND LOT: NGJV0169. THE THIRD PHOTO SHOWS BOTH, THE LABEL ON THE BOX AND THE LABEL ON THE PRODUCT PACKAGING, EVIDENCING THAT EVEN THOUGH THE LOT NUMBER IS THE SAME, THE PRODUCT NUMBER IS DIFFERENT SINCE THE LABEL IN THE PACKAGING SHOWS CAT NO: V072231 19FR ROUND HUBLESS. THE FOURTH PHOTO ZOOMS INTO THE PRODUCT LABEL (19FR). THE LAST PHOTO SHOWS THE PRODUCT INSIDE THE BOX, EVIDENCING AGAIN TO BE LABEL AS A 19FR. THE REPORTED EVENT IS CONFIRMED. THE ROOT CAUSE IDENTIFIED FOR CAPA: 11207399 IS: THE LABEL PROCESS DESCRIBED IN THE PROCEDURE WAS NOT FOLLOWED UP BY LABEL PRINTING TECHNICIAN, WHERE ESTABLISHED THAT BEFORE THE PRINTER IS RE-LOADED WITH A NEW MATERIAL LOT, THE LABEL PRINTING TECHNICIAN MUST TAKE THE FIRST LABEL OF THE AT LOT AND MARK WITH RED INK THE PRE-PRINTED MATERIAL PART NUMBER TO CONFIRM THAT IT IS ACCORDING TO THE PART NUMBER LISTED IN OPERATION 10 OF THE WORK ORDER. THIS LABEL SHOULD BE SIGNED, DATED, AND MUST BE INCLUDED IN THE DHR AS SAMPLE; A COMMENT DOCUMENTING THIS MATERIAL LOAD SHOULD BE ADDED IN THE FIRST ARTICLE INSPECTION FORM. DHR REVIEW IS NOT REQUIRED AS CAPA: 11207399 IS APPLICABLE FOR THIS PRODUCT LOT NUMBER. LABELING REVIEW IS NOT REQUIRED AS CAPA: 11207399 IS APPLICABLE FOR THIS PRODUCT LOT NUMBER. UDI FORMAT UPDATED WITH AVAILABLE PRODUCT INFORMATION PER GUDID. H11: SECTION A THROUGH F - THE INFORMATION PROVIDED BY BD REPRESENTS ALL THE KNOWN INFORMATION AT THIS TIME. DESPITE GOOD FAITH EFFORTS TO OBTAIN ADDITIONAL INFORMATION, THE COMPLAINANT / REPORTER WAS UNABLE OR UNWILLING TO PROVIDE ANY FURTHER PATIENT, PRODUCT, OR PROCEDURAL DETAILS TO BD.

Description of Event or Problem · 0

IT WAS REPORTED THAT THE CUSTOMER HAD TWO SEPARATE POS- PO:4517838642 & PO 4517885835 WHERE THEY HAD RECEIVED THE WRONG PRODUCT. THE BOX WAS MARKED CHANNEL DRAIN 15FR ROUND HUBLESS FULL FLUTED SILICONE WITH 4.7MM TROCAR, BUT THE BOXES ACTUALLY CONTAINED 19FR DRAINS, AND THEY NOW HAD 7 PLUS CASES OF 19FR DRAINS AND NO 15FR DRAINS.

Description of Event or Problem · 0

IT WAS REPORTED THAT THE CUSTOMER HAD TWO SEPARATE POS- PO: (B)(4) WHERE THEY HAD RECEIVED THE WRONG PRODUCT. THE BOX WAS MARKED CHANNEL DRAIN 15FR ROUND HUBLESS FULL FLUTED SILICONE WITH 4.7MM TROCAR, BUT THE BOXES ACTUALLY CONTAINED 19FR DRAINS, AND THEY NOW HAD 7 PLUS CASES OF 19FR DRAINS AND NO 15FR DRAINS. PER ADDITIONAL INFORMATION RECEIVED VIA MAIL ON 16DEC2024, STATED THAT THESE ARE ALL MISMATCHED. THEY NEVER MADE IT TO THE PATIENT BECAUSE IT WAS CAUGHT BEFORE THE STOCK WAS REFILLED.

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
1334460 CHANNEL DRAIN CHANNEL DRAIN GBX C.R. BARD INC. (COVINGTON) -1018233 NGJV0169 00801741119194

Patients

Seq Age Sex Outcome Treatment
1 NA Unknown Other