UNKNOWN BONE MORPHOGENETIC PROTEIN
Report
- Report Number
- 1030489-2011-00404
- Event Type
- Injury
- Date Received
- April 12, 2011
- Report Date
- March 14, 2011
- Manufacturer
- MEDTRONIC SOFAMOR DANEK
- Product Code
- NEK
- PMA / PMN Number
- UNK
- Adverse Event
- Yes
- Report Source
- Manufacturer report
- Reporter Location
- VA, US
- Reporter Occupation
- PHYSICIAN
Narratives
ARTICLE CITATION: WILLIAMS, BRIAN J., ET AL. DOES BMP INCREASE THE INCIDENCE OF PERIOPERATIVE COMPLICATIONS IN SPINAL FUSION? A COMPARISON OF 55,862 CASES OF SPINAL FUSION WITH AND WITHOUT BMP. SPINE 2011; (10.1097/BRS.0B013E318216D825). (B)(4). NEITHER THE DEVICE NOR FILMS OF APPLICABLE IMAGING STUDIES WERE RETURNED TO THE MANUFACTURER FOR EVALUATION. MULTIPLE PRODUCTS WERE IMPLANTED DURING THE PROCEDURE. ALTHOUGH IT IS UNKNOWN IF ANY OF THE DEVICES CONTRIBUTED TO THE REPORTED EVENT, WE ARE FILING THIS MDR FOR NOTIFICATION PURPOSES.
ALTHOUGH IT IS UNKNOWN IF THE DEVICE CONTRIBUTED TO THE REPORTED EVENT, WE ARE FILING THIS MDR FOR NOTIFICATION PURPOSES. THE PATIENTS' AVERAGE AGE WAS (B)(6) YEARS.
POST-OPERATIVE COMPLICATIONS WERE REPORTED FROM A RETROSPECTIVE ANALYSIS OF A MULTI-INSTITUTIONAL, MULTI-SURGEON DATABASE. THE FUSION CASES WERE PERFORMED FROM 2004 TO 2007 USING BMP. A VARIETY OF FUSION METHODS WERE USED (ANTERIOR CERVICAL, ANTERIOR/POSTERIOR, ANTERIOR THORALUMBAR, INTERLAMINAR FACET, POSTEROLATERAL, PLIF AND TILF). THE USE OF TWO DIFFERENT BONE MORPHOGENETIC PROTEINS (BMP) WAS NOTED IN THE LITERATURE ARTICLE (BMP-2 AND BMP-7); HOWEVER THE SUSPECT BMP WAS NOT IDENTIFIED WITH A PARTICULAR PATIENT COMPLICATION. SPECIFIC COMPLICATIONS WERE COLLECTED IN THE DATABASE WITH A FOCUS ON THE INTRA-OPERATIVE AND IMMEDIATE POST-OPERATIVE PERIODS. THERE WERE TWENTY-SEVEN REPORTS OF HEMATOMA / SEROMAS; TWENTY-FOUR REPORTS FOR PATIENTS WHO UNDERWENT POSTERIOR CERVICAL AND THORACOLUMBAR PROCEDURES AND THREE REPORTS FOR PATIENTS WHO UNDERWENT ANTERIOR CERVICAL PROCEDURES.
POST-OPERATIVE COMPLICATIONS WERE REPORTED FROM A RETROSPECTIVE ANALYSIS OF A MULTI-INSTITUTIONAL, MULTI-SURGEON DATABASE (SCOLIOSIS RESEARCH SOCIETY). THE FUSION CASES WERE PERFORMED FROM 2004 TO 2007 USING BMP. A VARIETY OF FUSION METHODS WERE USED (ANTERIOR CERVICAL, ANTERIOR/POSTERIOR, ANTERIOR THORALUMBAR, INTERLAMINAR FACET, POSTEROLATERAL, PLIF AND TILF). THE USE OF TWO DIFFERENT BONE MORPHOGENETIC PROTEINS (BMP) WAS NOTED IN THE LITERATURE ARTICLE (BMP-2 AND BMP-7); HOWEVER THE SUSPECT BMP WAS NOT IDENTIFIED WITH A PARTICULAR PATIENT COMPLICATION. BMP WAS USED IN 11,933 SPINAL FUSION CASES. THE PATIENTS' AVERAGE AGE WAS (B)(6) YEARS, INCLUDING PEDIATRICS. THERE WERE TWENTY-SEVEN REPORTS OF HEMATOMA / SEROMAS; TWENTY-FOUR REPORTS FOR PATIENTS WHO UNDERWENT POSTERIOR CERVICAL AND THORACOLUMBAR PROCEDURES AND THREE REPORTS FOR PATIENTS WHO UNDERWENT ANTERIOR CERVICAL PROCEDURES.
Devices
| Seq | Brand | Generic | Product Code | Manufacturer | Model | Lot | UDI-DI |
|---|---|---|---|---|---|---|---|
| 1 | UNKNOWN BONE MORPHOGENETIC PROTEIN | FILLER, RECOMBINANT HUMAN BONE MORPHOGENETIC PROTEIN, COLLAGEN SCAFFOLD WITH MET | NEK | MEDTRONIC SOFAMOR DANEK | NA | NA |
Patients
| Seq | Age | Sex | Outcome | Treatment |
|---|---|---|---|---|
| 1 | 00052 YR |