O-ARM IMAGING SYSTEM
Report
- Report Number
- 3004785967-2024-00608
- Event Type
- Malfunction
- Date Received
- October 18, 2024
- Date of Event
- February 1, 2024
- Report Date
- October 18, 2024
- Manufacturer
- MEDTRONIC NAVIGATION, INC (LITTLETON)
- Product Code
- OXO
- Product Problem
- Yes
- Report Source
- Manufacturer report
- Reporter Location
- US
- Reporter Occupation
- OTHER HEALTH CARE PROFESSIONAL
- Health Professional
- Yes
Narratives
A1-A5) PATIENT INFORMATION WAS NOT INCLUDED IN THE JOURNAL ENTRY B3) THE ARTICLE DID NOT PROVIDE THE DATE OF THE PROCEDURE. THE EVENT DATE PROVIDED IS THE ACCEPTED DATE. B5) THE ARTICLE CITATION IS INCLUDED. D4) THE SYSTEM PRODUCT NUMBER AND SERIAL NUMBER WERE NOT PROVIDED IN THE JOURNAL ARTICLE. UDI NOT AVAILABLE FOR THIS SYSTEM. G2) NO 510K PROVIDED AS SYSTEM IS UNKNOWN. H3) NO EVALUATION WAS PERFORMED AS THE EVENT WAS REPORTED AS A LITERATURE ARTICLE. H4) DEVICE MANUFACTURING DATE IS UNAVAILABLE. MEDTRONIC SUBMITS THIS REPORT TO COMPLY WITH FDA REGULATIONS 21 CFR PARTS 4 AND 803. MEDTRONIC HAS MADE REASONABLE EFFORTS TO PROVIDE AS MUCH RELEVANT INFORMATION AS IS AVAILABLE TO THE COMPANY AS OF THE SUBMISSION DATE OF THIS REPORT. THIS REPORT DOES NOT CONSTITUTE AN ADMISSION OR A CONCLUSION BY FDA, MEDTRONIC, OR ITS EMPLOYEES THAT THE DEVICE, MEDTRONIC, OR ITS EMPLOYEE CAUSED OR CONTRIBUTED TO THE EVENT DESCRIBED IN THE REPORT. ANY REQUIRED FIELDS THAT ARE UNPOPULATED ARE BLANK BECAUSE THE INFORMATION IS CURRENTLY UNKNOWN OR UNAVAILABLE. MEDTRONIC WILL SUBMIT A SUPPLEMENTAL REPORT IF ADDITIONAL RELEVANT INFORMATION BECOMES KNOWN.
CITATION: FEIZI, A., BELL, C. E., ROYTMAN, G. R., PARK, N., WANG, A., TOMMASINI, S., & WIZNIA, D. (2024). USING COMPUTED TOMOGRAPHY-BASED THREE-DIMENSIONAL MODELING AND COMPUTER NAVIGATION FOR MINIMALLY INVASIVE CORE DECOMPRESSION AND ADJUVANT ORTHOBIOLOGIC THERAPY OF FEMORAL HEAD AVASCULAR NECROSIS. ARTHROPLASTY TODAY, 26, 101337. HTTPS://DOI.ORG/10.1016/J.ARTD.2024.101337 ABSTRACT: AVASCULAR NECROSIS OF THE FEMORAL HEAD IS A DEBILITATING CONDITION THAT CAN LEAD TO FEMORAL HEAD COLLAPSE. CORE DECOMPRESSION WITH ADJUVANT CELLULAR THERAPIES, SUCH AS BONE MARROW ASPIRATE CONCENTRATE, DELAYS DISEASE PROGRESSION AND IMPROVES OUTCOMES. HOWEVER, INCONSISTENT RESULTS IN THE LITERATURE MAY BE DUE TO LIMITATIONS IN SURGICAL TECHNIQUE AND DIFFICULTY IN TARGETING THE NECROTIC LESIONS. HERE, WE PRESENT A SURGICAL TECHNIQUE UTILIZING COMPUTED TOMOGRAPHY-BASED THREE-DIMENSIONAL MODELING AND INSTRUMENT TRACKING TO GUIDE THE THERAPY TO THE CENTER OF THE LESION. THIS METHOD MINIMIZES THE NUMBER OF ATTEMPTS TO REACH THE LESION AND CONFIRMS THE THREE-DIMENSIONAL POSITIONING OF THE INSTRUMENTATION WITHIN THE LESION. OUR TECHNIQUE MAY IMPROVE THE OUTCOMES OF CORE DECOMPRESSION AND ADJUVANT THERAPY AND PREVENT OR DELAY HIP COLLAPSE IN PATIENTS WITH FEMORAL HEAD AVASCULAR NECROSIS. REPORTED EVENT: THIRTY-ONE PATIENTS WERE TREATED FOR AVASCULAR NECROSIS (AVN) OF THE FEMUR BY USING MINIMALLY INVASIVE CORE DECOMPRESSION AND ADJUVANT ORTHOBIOLOGIC THERAPY. ONE PATIENT REQUIRED 2 NEEDLE ENTRY ATTEMPTS DUE TO A SLIGHT DEVIATION OF THE NEEDLE AT THE SOFT-TISSUE AND BONE BOUNDARY. SEE ATTACHED LITERATURE ARTICLE.
Devices
| Seq | Brand | Generic | Product Code | Manufacturer | Model | Lot | UDI-DI |
|---|---|---|---|---|---|---|---|
| 1716122 | O-ARM IMAGING SYSTEM | IMAGE-INTENSIFIED FLUOROSCOPIC X-RAY SYSTEM, M | OXO | MEDTRONIC NAVIGATION, INC (LITTLETON) | UNK_OARM_SYS |
Patients
| Seq | Age | Sex | Outcome | Treatment |
|---|---|---|---|---|
| 1 | NA | Unknown |