NEXUS® BONESCALPEL® 25MM, BLUNT BLADE + IRRIGATION TUBING KIT
Report
- Report Number
- 2435119-2024-00018
- Event Type
- Injury
- Date Received
- October 14, 2024
- Date of Event
- August 29, 2024
- Report Date
- October 14, 2024
- Manufacturer
- MISONIX, INC.
- Product Code
- LFL
- PMA / PMN Number
- K231117
- Adverse Event
- Yes
- Report Source
- Manufacturer report
- Reporter Location
- CA
- Reporter Occupation
- PHYSICIAN
- Health Professional
- Yes
Narratives
ON SEPTEMBER 03, 2024, MISONIX® LLC., A BIOVENTUS® CO., RECEIVED NOTIFICATION OF THERMAL INJURY DURING A PROCEDURE THAT OCCURRED ON (B)(6) 2024. PART NUMBERS AND LOT NUMBERS WERE NOT AVAILABLE IN THE INITIAL NOTIFICATION TO CONFIRM MISONIX PRODUCTS WERE USED DURING THE EVENT. MULTIPLE FOLLOW-UPS WERE CONDUCTED TO OBTAIN THIS INFORMATION TO PROCESS THE EVENT IN OUR QUALITY SYSTEM, IF APPLICABLE. ON OCTOBER 04, 2024, MISONIX RECEIVED AN UPDATE ON THE DETAILS OF THE EVENT WHICH CONFIRMED THE PART NUMBERS IN USE AT THE TIME TO BE MISONIX PRODUCT PART NUMBERS. SPECIFICALLY, WHILE USING A NEXUS® STANDARD HANDPIECE (P/N: 100-21-0000) WITH A NEXUS® BONESCALPEL® 25MM, BLUNT BLADE + IRRIGATION TUBING KIT (P/N: 110-31-1125) THE PATIENT EXPERIENCED THERMAL INJURY TO THE UPPER AND LOWER LIP DURING THE PROCEDURE. THE SURGEON WHO REPORTED THE EVENT DID NOT KNOW WHICH DEVICE CAUSED THE BURN, OR IF THE SURGICAL TECHNIQUE AS DESCRIBED IN THE INSTRUCTIONS FOR USE MANUAL WAS PROPERLY FOLLOWED TO PREVENT THERMAL INJURY TO THE PATIENT OR USER. THE DEGREE OF THE BURN WAS NOT SPECIFIED. PERMANENT IMPAIRMENT TO BODY STRUCTURE OR BODY FUNCTION WAS NOT REPORTED. DELAY IN TREATMENT WAS NOT REPORTED. HOWEVER, MEDICAL INTERVENTION WAS REQUIRED TO TREAT THE BURN WITH CREAM. THE SERIAL NUMBER FOR THE NEXUS® STANDARD HANDPIECE (P/N: 100-21-0000) AND THE LOT NUMBER FOR THE NEXUS® BONESCALPEL® 25MM, BLUNT BLADE + IRRIGATION TUBING KIT (P/N: 110-31-1125) USED AT THE TIME OF THE EVENT WERE NOT REPORTED; THEREFORE, A COMPLETE DEVICE HISTORY RECORD REVIEW CANNOT BE PERFORMED. A REVIEW OF POST MARKET SURVEILLANCE DATA FOR THE NEXUS® SYSTEM DID NOT SHOW ANY SIGNIFICANT ADVERSE TRENDS FOR THERMAL INJURY TO THE PATIENT OR USER. THE CURRENT FREQUENCY OF OCCURRENCE IS WITHIN THE FREQUENCY IN THE ORIGINAL RISK MANAGEMENT REPORT. THERE IS NO CHANGE TO THE RESIDUAL RISK OR RISK-BENEFIT RATIO OF THE DEVICE. DUE TO THE NATURE IN WHICH ULTRASONIC DEVICES TRANSFER ENERGY INTO THE TARGET TISSUE, THERMAL EVENTS MAY OCCUR. THE INSTRUCTIONS FOR USE MANUAL (100-10-1000, REVISION K) FOR THE NEXUS® ULTRASONIC SURGICAL ASPIRATION SYSTEM CONTAINS THE FOLLOWING WARNINGS AND CAUTIONS REGARDING THE SURGICAL TECHNIQUE AND DEVICE SETTINGS REQUIRED TO PREVENT THERMAL INJURY TO THE PATIENT OR USER: WARNING THE NEXUS® ULTRASONIC SURGICAL ASPIRATOR SYSTEM IS INTENDED TO BE USED IN VARIOUS TYPES OF INVASIVE, SURGICAL PROCEDURES. THERE MAY BE INDIRECT DANGER TO THE PATIENT SHOULD THE DEVICE FAIL DURING THE PROCEDURE. IT IS RECOMMENDED THAT THE FACILITY FOLLOWS ITS BACK-UP EQUIPMENT PROTOCOLS. CAUTION THE SYSTEM CHECK SHOULD ALWAYS BE DONE IN ADVANCE OF PREPARING PATIENT FOR SURGERY TO MINIMIZE RISK TO PATIENT IN CASE OF SYSTEM MALFUNCTION. CAUTION IT IS STRONGLY ADVISED THAT A STERILE BACKUP HANDPIECE BE READILY AVAILABLE IN THE OPERATING ROOM AS INSURANCE ANY CONTAMINATION OR MALFUNCTION OF THE HANDPIECE USED DURING SURGERY. POTENTIAL BURN HAZARD. WARNING NEXUS® PROBES HAVE A SILICONE OR HARD PLASTIC SHEATH. COMPRESSING OR BENDING THE SHEATH MAY CAUSE THE SHEATH TO CONTACT THE VIBRATING SURFACE ALONG THE LENGTH OF THE PROBE OR AT THE PROBE TIP AND MAY CAUSE EXCESSIVE HEATING, WHICH MAY BURN USER OR PATIENT TISSUE AT THE SURGICAL SITE. WARNING EXCESSIVE LOADING OF NEXUS® PROBES AT THE SURGICAL SITE MAY INDUCE HEATING DUE TO VIBRATION AND FRICTION AS TARGET TISSUE IS FRAGMENTED AND EMULSIFIED. IT IS CRITICAL TO MANAGE THE TEMPERATURE OF THE PROBE BY ADJUSTING THE IRRIGATION, ASPIRATION, AND ULTRASOUND SETTINGS, AND SURGICAL TECHNIQUE. TISSUE NECROSIS MAY RESULT IF PROBE TIP IS NOT MOVED RELATIVE TO TISSUE. A CONTINUOUS, LATERAL SWEEPING MOTION IS RECOMMENDED IN ORDER TO MINIMIZE CONTACT DURATION WITH THE ULTRASONIC PROBE TIP AND MINIMIZE HEAT BUILD-UP. WHEN LATERAL MOTION IS NOT POSSIBLE WITHDRAW AND RE-INSERT PROBE TIP FREQUENTLY. WARNING CONTACT TO VIBRATING ELEMENTS LIKE AN EXTENSION AND ULTRASONIC PROBE TIP MAY CAUSE BURNS AND SHOULD BE AVOIDED BY ALL MEANS. THE HANDPIECE SHOULD ONLY BE HELD AT THE BLACK HANDPIECE HOUSING AREA AND/OR THE BLACK HARD SHEATH. WARNING A PROTECTIVE SILICONE SLEEVE, INCLUDED WITH CERTAIN PROBE TIPS, REDUCES THE RISK OF THERMAL DAMAGE BUT DOES NOT ELIMINATE IT. CONTACT WITH THE SILICONE SLEEVE SHOULD BE AVOIDED OR KEPT BRIEF WITH MINIMAL AMOUNT OF CONTACT PRESSURE. PRESSURE AND EXTENDED EXPOSURE CAN STILL RESULT IN EXCESSIVE FRICTIONAL HEAT AND CAUSE BURNS. WARNING CONTACT OF THE RIGID OR SILICONE SHEATHS WITH PATIENT TISSUE UNDER PRESSURE, MAY CREATE A BURN HAZARD. AVOID CONTACT OF SHEATH ELEMENTS WITH PATIENT TISSUE UNDER PRESSURE. WARNING PROBE TIP TEMPERATURES MAY EXCEED THE TISSUE NECROSIS POINT IF INSUFFICIENT IRRIGANT IS PRESENT AT THE PROBE TIP-TISSUE INTERFACE. FOR HARD TISSUE REMOVAL, ALWAYS USE THE MAXIMUM IRRIGATION FLOWRATE THAT DOES NOT AFFECT THE SURGICAL FIELD OF VIEW, OR IMPACT SURGICAL TECHNIQUE. ADDITIONAL EXTERNAL IRRIGATION, E.G., BY ADMINISTERING STERILE SALINE WITH A SYRINGE OVER THE DISTAL PROBE TIP PORTION, MAY BE NECESSARY FOR REMOVAL OF VERY DENSE, HARD OSSEOUS STRUCTURES. WARNING HARD TISSUE APPLICATIONS, A MINIMUM IRRIGATION SETTING OF (B)(4) IS RECOMMENDED TO MINIMIZE OR PREVENT THERMAL INJURY AND/OR TISSUE NECROSIS. CAUTION INSUFFICIENT IRRIGATION AND HIGH TIP PRESSURE (LOADING) UNDER EXTENDED EXPOSURE, E.G., IN TIGHT CAVITIES, ARE TO BE AVOIDED WHILE REMOVING HARD TISSUE. IT IS RECOMMENDED TO WITHDRAW AND RE-INSERT THE ULTRASONIC TIPS (E.G., BLADES & SHAVERS) REPEATEDLY TO RE-ESTABLISH ADEQUATE COOLING AND LUBRICATION. CAUTION ADDITIONAL EXTERNAL IRRIGATION, E.G., BY ADMINISTERING STERILE SALINE WITH A SYRINGE OVER THE DISTAL TIP PORTION, MAY BE NECESSARY WHEN REMOVING VERY DENSE, HARD OSSEOUS STRUCTURES. CAUTION PRIME THE IRRIGATION TUBING PRIOR TO USE. AT ALL TIMES ENSURE THAT THE IRRIGATION FLOWS TOWARDS THE HANDPIECE WHEN FOOTSWITCH IS DEPRESSED. IF NO IRRIGATION IS FLOWING, CEASE USE UNTIL FLOW IS RESTORED. MISONIX IS CURRENTLY IN THE PROCESS OF SCHEDULING A CALL WITH THE SURGEON TO DISCUSS THE EVENT IN DETAIL. AS OF THE DATE OF THIS REPORT, THE HANDPIECE AND DISPOSABLE USED AT THE TIME OF THE EVENT HAVE NOT YET BEEN RETURNED FOR EVALUATION. A FOLLOW UP REPORT WILL BE SUBMITTED ONCE ALL COMMUNICATION HAS TAKEN PLACE AND THE DEVICES HAVE BEEN EVALUATED TO DETERMINE POTENTIAL ROOT CAUSE.
ON (B)(6) 2024, MISONIX® LLC., A BIOVENTUS® CO., RECEIVED NOTIFICATION OF THERMAL INJURY DURING A PROCEDURE THAT OCCURRED ON (B)(6) 2024. PART NUMBERS AND LOT NUMBERS WERE NOT AVAILABLE IN THE INITIAL NOTIFICATION TO CONFIRM MISONIX PRODUCTS WERE USED DURING THE EVENT. MULTIPLE FOLLOW-UPS WERE CONDUCTED TO OBTAIN THIS INFORMATION TO PROCESS THE EVENT IN OUR QUALITY SYSTEM, IF APPLICABLE. ON (B)(6) 2024, MISONIX RECEIVED AN UPDATE ON THE DETAILS OF THE EVENT WHICH CONFIRMED THE PART NUMBERS IN USE AT THE TIME TO BE MISONIX PRODUCT PART NUMBERS. SPECIFICALLY, WHILE USING A NEXUS® STANDARD HANDPIECE (P/N: 100-21-0000) WITH A NEXUS® BONESCALPEL® 25MM, BLUNT BLADE + IRRIGATION TUBING KIT (P/N: 110-31-1125) THE PATIENT EXPERIENCED THERMAL INJURY TO THE UPPER AND LOWER LIP DURING THE PROCEDURE. THE SURGEON WHO REPORTED THE EVENT DID NOT KNOW WHICH DEVICE CAUSED THE BURN, OR IF THE SURGICAL TECHNIQUE AS DESCRIBED IN THE INSTRUCTIONS FOR USE MANUAL WAS PROPERLY FOLLOWED TO PREVENT THERMAL INJURY TO THE PATIENT OR USER. THE DEGREE OF THE BURN WAS NOT SPECIFIED. PERMANENT IMPAIRMENT TO BODY STRUCTURE OR BODY FUNCTION WAS NOT REPORTED. DELAY IN TREATMENT WAS NOT REPORTED. HOWEVER, MEDICAL INTERVENTION WAS REQUIRED TO TREAT THE BURN WITH CREAM.
Devices
| Seq | Brand | Generic | Product Code | Manufacturer | Model | Lot | UDI-DI |
|---|---|---|---|---|---|---|---|
| 1847608 | NEXUS® BONESCALPEL® 25MM, BLUNT BLADE + IRRIGATION TUBING KIT | 25MM, BLUNT BLADE + IRRIGATION TUBING KIT | LFL | MISONIX, INC. | 110-31-1125 |
Patients
| Seq | Age | Sex | Outcome | Treatment |
|---|---|---|---|---|
| 1 | NA | Unknown | Other |