FDA Adverse Event Injury Summary report: N

XIENCE V EVEROLIMUS ELUTING CORONARY STENT SYSTEM

MDR report key: 2040173 · Received April 5, 2011

Report

Report Number
2024168-2011-02366
Event Type
Injury
Date Received
April 5, 2011
Date of Event
May 6, 2010
Report Date
March 11, 2011
Manufacturer
AV-TEMECULA-CT
Product Code
NIQ
PMA / PMN Number
P070015
Adverse Event
Yes
Report Source
Manufacturer report
Reporter Location
NY, US
Reporter Occupation
HEALTH PROFESSIONAL

Narratives

Additional Manufacturer Narrative · 1

(B)(4). DURING PROCESSING OF THIS COMPLAINT, ATTEMPTS WERE MADE TO OBTAIN COMPLETE EVENT, PATIENT AND DEVICE INFORMATION. THE XIENCE V 2.5 X 23 MM IS BEING REPORTED UNDER A SEPARATE MEDWATCH REPORT NUMBER. THERE WAS NO REPORTED PRODUCT DEFICIENCY. ANGINA, ISCHEMIA, MYOCARDIAL INFARCTION, AND RESTENOSIS ARE KNOWN ADVERSE EVENTS AS LISTED IN THE XIENCE V INSTRUCTIONS FOR USE (IFU). ALTHOUGH A CONCLUSIVE CAUSE FOR THE REPORTED PATIENT EFFECTS AND THE RELATIONSHIP TO THE DEVICE, IF ANY, CANNOT BE DETERMINED; THERE IS NO INDICATION OF A PRODUCT QUALITY DEFICIENCY WITH RESPECT TO MANUFACTURE, DESIGN, OR LABELING. SINCE IT WAS REPORTED THAT THE 3.0 X 23 MM XIENCE V STENT WAS IMPLANTED VIA DIRECT STENTING, IT SHOULD BE NOTED THAT THE XIENCE V IFU STATES: PRE-DILATE THE LESION WITH A PTCA CATHETER OF APPROPRIATE LENGTH AND DIAMETER FOR THE VESSEL/LESION TO BE TREATED. IN THIS CASE, IT CANNOT BE DETERMINED WHETHER THE IFU DEVIATION CONTRIBUTED TO THE REPORTED PATIENT EFFECTS.

Description of Event or Problem · 1

IT WAS REPORTED THAT APPROXIMATELY SEVEN MONTHS POST XIENCE V STENTING PROCEDURE WITH ONE 2.5 X 23 STENT IMPLANTATION IN A RESTENOSED, NON-ABBOTT STENTED LESION, IN THE FIRST OBTUSE MARGINAL ARTERY, ONE 3.0 X 23 STENT, WHICH WAS DIRECTLY STENTED WITHOUT PRE-DILATATION IN THE MID LEFT ANTERIOR DESCENDING ARTERY AND ONE 2.5 X 23 STENT IN THE FIRST DIAGONAL ARTERY, THE PATIENT WAS HOSPITALIZED WITH A COUGH, SHORTNESS OF BREATH AND CHEST PAIN. ON (B)(6) 2010, CARDIAC ENZYMES (TROPONIN I) WERE ELEVATED, THE ECG SHOWED REVERSIBLE CHANGE CONSISTENT WITH ISCHEMIA AND THE PATIENT WAS DIAGNOSED WITH A NON-ST ELEVATION MYOCARDIAL INFARCTION. CARDIAC CATHETERIZATION SHOWED A PATENT STENT IN THE FIRST DIAGONAL ARTERY, NEW LESION IN THE PROXIMAL LEFT ANTERIOR DESCENDING ARTERY AND RESTENOSIS IN THE FIRST OBTUSE MARGINAL ARTERY WHICH WAS NOT TREATED. THE PATIENT UNDERWENT PERCUTANEOUS CORONARY REVASCULARIZATION STENTING IN THE PROXIMAL LEFT ANTERIOR DESCENDING ARTERY TARGET VESSEL, NON-TARGET LESION ON (B)(6) 2010. THE PATIENT'S CONDITION RESOLVED AND THE PATIENT WAS DISCHARGED ON (B)(6) 2010. THERE WAS NO ADDITIONAL INFORMATION PROVIDED.

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
1 XIENCE V EVEROLIMUS ELUTING CORONARY STENT SYSTEM DRUG ELUTING CORONARY STENT SYSTEM NIQ AV-TEMECULA-CT 9051841

Patients

Seq Age Sex Outcome Treatment
1 73 YR Hospitalization| R| S ASPIRINCLOPIDOGREL