THORATEC® HEARTMATE 3® LVAS IMPLANT KIT
Report
- Report Number
- 2916596-2024-06402
- Event Type
- Death
- Date Received
- October 8, 2024
- Date of Event
- January 1, 2022
- Report Date
- November 13, 2024
- Manufacturer
- THORATEC CORPORATION
- Product Code
- DSQ
- UDI-DI
- 00813024013297
- PMA / PMN Number
- P160054
- Adverse Event
- Yes
- Report Source
- Manufacturer report
- Reporter Location
- CA, US
- Reporter Occupation
- 003
Narratives
SECTIONS A AND D: SPECIFIC PATIENT INFORMATION AND DEVICE SERIAL NUMBER ARE DOCUMENTED AS UNKNOWN. DETAILS ARE LISTED IN THE ATTACHED ABSTRACT. DEVICE WAS IMPLANTED AT TIME OF EVENT. SECTION B3: DATE OF EVENT HAS BEEN ENTERED AS AN ESTIMATED DATE ¿ 01JAN2022 ¿ SINCE THE DATES OF DATA COLLECTION OCCURRED BETWEEN 2017 AND 2022. SECTION B3: DATE OF DEATH IS UNKNOWN. SECTION G2: REPORT SOURCE CORRECTED. SECTION H6: HEALTH EFFECT - CLINICAL CODE CORRECTED. AUTHOR INFORMATION: AUSTIN KLUIS ET AL. SURGERY IN PRACTICE AND SCIENCE 17 (2024) 100242. HTTPS://DOI.ORG/10.1016/J.SIPAS.2024.100242. MANUFACTURER'S INVESTIGATION CONCLUSION: A DIRECT CORRELATION BETWEEN HEARTMATE (HM) 3 LEFT VENTRICULAR ASSIST SYSTEM (LVAS) AND THE REPORTED PATIENT OUTCOME COULD NOT BE CONCLUSIVELY DETERMINED THROUGH THIS EVALUATION. THE RESEARCH ARTICLE TITLED, ¿PREOPERATIVE PULMONARY FUNCTION IS ASSOCIATED WITH LEFT VENTRICULAR ASSIST DEVICE OUTCOMES¿, WAS RECEIVED. THE STUDY CONCLUDED THAT PREOPERATIVE PULMONARY FUNCTION WAS ASSOCIATED WITH SHORT-TERM LVAD SURVIVAL, POSTOPERATIVE VENTILATORY TIME, AND NEED FOR TRACHEOSTOMY. THE DEVICE SERIAL NUMBERS OR OTHER IDENTIFYING INFORMATION OF THE PRODUCTS WAS NOT REPORTED AND WAS NOT ABLE TO BE DETERMINED DURING THE INVESTIGATION. THE HEARTMATE 3 LVAS IFU IS CURRENTLY AVAILABLE. SECTION 1 OF THE IFU, ¿INTRODUCTION¿, LISTS POTENTIAL ADVERSE EVENTS, INCLUDING DEATH, THAT MAY BE ASSOCIATED WITH THE USE OF THE HEARTMATE 3 LEFT VENTRICULAR ASSIST SYSTEM. NO FURTHER INFORMATION WAS PROVIDED. THE MANUFACTURER IS CLOSING THE FILE ON THIS EVENT.
SECTION D4: DEVICE SERIAL NUMBER AND LOT NUMBER WERE NOT PROVIDED, AND EXPIRATION DATE AND MANUFACTURE DATE (H4) CANNOT BE DETERMINED. THE PRIMARY UDI NUMBER IN D4 IS REFLECTIVE OF ALL AVAILABLE INFORMATION. NO FURTHER INFORMATION WAS PROVIDED. A SUPPLEMENTAL REPORT WILL BE SUBMITTED ONCE THE MANUFACTURER¿S INVESTIGATION IS COMPLETE.
IT WAS REPORTED THROUGH THE RESEARCH ARTICLE TITLED ¿PREOPERATIVE PULMONARY FUNCTION IS ASSOCIATED WITH LEFT VENTRICULAR ASSIST DEVICE OUTCOMES¿ IDENTIFYING THAT HM3 MAY BE RELATED TO INCREASE OF VENTILATION REQUIREMENT, INCREASE OF PULMONARY DYSFUNCTION AND DEATH IN PATIENT WITH PRE-DIAGNOSED PULMONARY DYSFUNCTION THAT WERE IMPLANTED WITH HM3. THIS WAS A RETROSPECTIVE OBSERVATIONAL STUDY WHICH INCLUDED ALL HM3 IMPLANTS (N=107) FROM 2017 THROUGH 2022. THE AIM OF THIS STUDY WAS TO BETTER UNDERSTAND THE RELATIONSHIP BETWEEN PRE-EXISTING PULMONARY DYSFUNCTION AND SURVIVAL AFTER LVAD IMPLANTATION. OVERALL, 30-DAY AND 1-YEAR SURVIVAL WERE 98.10 % AND 86.83 % RESPECTIVELY. WHEN STRATIFIED BY TYPE OF PREOPERATIVE PULMONARY SUPPORT, PATIENTS ON ROOM AIR OR REQUIRING ONLY NASAL CANNULA SUPPORT HAD IMPROVED SURVIVAL COMPARED TO THOSE REQUIRING NONINVASIVE OR INVASIVE POSITIVE PRESSURE VENTILATION AT 1-YEAR. THE MEDIAN OVERALL POSTOPERATIVE MECHANICAL VENTILATORY TIME WAS 20.38H OR 0.8 DAYS. A TOTAL OF 18 (16.82 %) PATIENTS REQUIRED POSTOPERATIVE TRACHEOSTOMY WHICH WAS PERFORMED A MEDIAN OF 7 [4¿9] DAYS AFTER SURGERY. INCREASINGLY INTENSIVE PREOPERATIVE METHODS OF PULMONARY SUPPORT WERE ASSOCIATED WITH AN INCREASE IN POSTOPERATIVE MECHANICAL VENTILATION TIME AND WITH AN INCREASED NEED FOR POSTOPERATIVE TRACHEOSTOMY. BECAUSE OF THE COMPLEXITY OF ASSESSING PREOPERATIVE PULMONARY FUNCTION, THE ANALYSIS WAS STRATIFIED IN DIFFERENT WAYS. FIRST, WHEN STRATIFIED BY THE TYPE OF PREOPERATIVE PULMONARY SUPPORT, IT WAS FOUND THAT PATIENTS ON ROOM AIR OR ONLY NASAL CANNULA HAD SIGNIFICANTLY IMPROVED SHORT-TERM SURVIVAL COMPARED TO THOSE REQUIRING MORE INVASIVE MODES OF VENTILATION. SECOND, PATIENTS WERE STRATIFIED BASED ON PRE-OPERATIVE LEVEL OF FIO2 REQUIRED. INCREASING FIO2 WAS STRONGLY ASSOCIATED WITH SHORT-TERM MORTALITY. THIRD, PATIENTS STRATIFIED BY PFT VALUES, SPECIFICALLY FEV1, THE LOWEST TERTILE OF FEV1 WAS STRONGLY ASSOCIATED WITH 1-YEAR MORTALITY ON BOTH UNIVARIATE AND MULTIVARIABLE ANALYSIS. ALTHOUGH FEV1 SEEMED TO HAVE THE STRONGEST DISCRIMINATORY POWER, IT IS ALSO THE HARDEST TO OBTAIN AS MANY HOSPITALIZED PATIENTS ARE TOO UNSTABLE FOR FORMAL PFT TESTING OR EVEN BEDSIDE SPIROMETRY. THESE RESULTS SUGGEST THAT INCREASED PREOPERATIVE PULMONARY DYSFUNCTION ¿ WHETHER DETERMINED BY ABSOLUTE FIO2, MODE OF PREOPERATIVE VENTILATORY SUPPORT, OR FORMAL FEV1 ASSESSMENT ¿ IS STRONGLY ASSOCIATED WITH SHORT-TERM MORTALITY.
Devices
| Seq | Brand | Generic | Product Code | Manufacturer | Model | Lot | UDI-DI |
|---|---|---|---|---|---|---|---|
| 19729 | THORATEC® HEARTMATE 3® LVAS IMPLANT KIT | VENTRICULAR (ASSIST) BYPASS | DSQ | THORATEC CORPORATION | 106524US | 00813024013297 |
Patients
| Seq | Age | Sex | Outcome | Treatment |
|---|---|---|---|---|
| 1 | NA | Unknown | Death |