TALENT THORACIC STENT GRAFT SYSTEM
Report
- Report Number
- 2953200-2011-00686
- Event Type
- Injury
- Date Received
- March 23, 2011
- Date of Event
- February 21, 2011
- Report Date
- February 21, 2011
- Manufacturer
- MEDTRONIC IRELAND
- Product Code
- MIH
- PMA / PMN Number
- P070007
- Removal / Correction Number
- NA
- Adverse Event
- Yes
- Report Source
- Manufacturer report
- Reporter Location
- JA
- Reporter Occupation
- PHYSICIAN
Narratives
(B)(4). EVAL, RESULTS: (ENDOLEAK, DISSECTION), (PRIOR DISSECTION), (EXISTING SYNTHETIC GRAFT). CONCLUSIONS: (DISSECTION).
A TALENT THORACIC STENT GRAFT SYSTEM WAS IMPLANTED IN A PT FOR THE ENDOVASCULAR TREATMENT OF A SACCULAR ANEURYSM WITH A DIAMETER OF 50 MM AND A LENGTH OF 26 MM, AT ZONE 4 AND CHRONIC TYPE B DISSECTION, APPROX 1 MONTH AGO. THE PT PREVIOUSLY HAD A SYNTHETIC GRAFT PLACED IN THE THORACIC AORTA, WHICH WAS THEN REPLACED DUE TO A CHRONIC TYPE B DISSECTION. THE PROXIMAL THORACIC NECK DIAMETER WAS 30 MM WITH A DISTAL THORACIC NECK DIAMETER OF 22MM. A TALENT TF2626 WAS SUCCESSFULLY IMPLANTED IN THE DISTAL SECTION OF THE TAA. IT WAS REPORTED THAT DURING THE DEPLOYMENT OF THE TALENT TW3228 IN THE PROXIMAL PORTION OF THE TAA, THE COVERED APEX OF THE STENT GRAFT WAS DEPLOYED MISALIGNED RESULTING IN A TYPE I ENDOLEAK. (REF MFR 2953200-2011-00685). A TALENT TAXF3232 WAS THEN IMPLANTED PROXIMALLY, TO TREAT THE TYPE I ENDOLEAK, HOWEVER THE TYPE I ENDOLEAK WAS NOT RESOLVED. THE PHYSICIAN MODELED THE STENT GRAFT WITH A BALLOON SEVERAL TIMES HOWEVER WAS UNABLE TO RESOLVE THE ENDOLEAK. THE PHYSICIAN DECIDED TO MONITOR THE PT W/O ANY ADD'L TREATMENT AND THUS COMPLETED THE PROCEDURE. IT WAS REPORTED THAT TWO DAYS LATER THE PT COMPLAINED OF BACK PAIN. A CT PERFORMED THE FOLLOWING DAY SHOWED A TYPE B DISSECTION AT THE DISTAL SIDE OF THE SYNTHETIC GRAFT, AND AN ANEURYSM DIAMETER OF 52 MM, W/O ANEURYSM RUPTURE OR STENT GRAFT MIGRATION. AS THERE WAS A POSSIBILITY OF RUPTURE DUE TO THE CONTINUOUS BACK PAIN, THE PHYSICIAN IMPLANTED TWO STENT GRAFTS (TF2424, TF3030) OVERLAPPING THE PREVIOUS THORACIC STENT GRAFT AND COVERING THE DISSECTION. (REF MFR 2953200-2011-00687). THE PHYSICIAN ASSESSED THAT THE TYPE IA ENDOLEAK HAD NO RELATION TO THE TALENT STENT GRAFT, BUT WAS RELATED TO THE PROCEDURE. THE PHYSICIAN ALSO DETERMINED THAT THE TYPE B DISSECTION, AT THE DISTAL SIDE OF THE SYNTHETIC GRAFT, MAY HAVE BEEN CAUSED BY THE REPEATED MODELING WITH A BALLOON TO RESOLVE THE ENDOLEAK. THE PHYSICIAN BELIEVES THAT THE DISSECTION IS RELATED TO THE PROCEDURE. NO CLINICAL SEQUELAE WERE REPORTED AND THE PT IS STABLE.
Devices
| Seq | Brand | Generic | Product Code | Manufacturer | Model | Lot | UDI-DI |
|---|---|---|---|---|---|---|---|
| 1 | TALENT THORACIC STENT GRAFT SYSTEM | MIH | MEDTRONIC IRELAND | NA | V00798512 |
Patients
| Seq | Age | Sex | Outcome | Treatment |
|---|---|---|---|---|
| 1 | 66 YR | Required Intervention |