QUICKSILVER BIPOLAR COAGULATION PROBE
Report
- Report Number
- 1037905-2011-00145
- Event Type
- Malfunction
- Date Received
- March 16, 2011
- Date of Event
- February 3, 2011
- Report Date
- February 14, 2011
- Manufacturer
- WILSON-COOK MEDICAL, INC.
- Product Code
- KNS
- PMA / PMN Number
- K990145
- Product Problem
- Yes
- Report Source
- Manufacturer report
- Reporter Location
- CA, US
- Reporter Occupation
- OTHER
Narratives
EVAL: THE PRODUCT SAID TO BE INVOLVED WAS RETURNED TO COOK FOR EVAL ON (B)(4) 2011. THE PRODUCT WAS RETURNED TO OUR APPROVED PROBE SUPPLIER FOR EVAL. WE HAVE NOT YET RECEIVED THE EVAL RESULTS FROM THE APPROVED SUPPLIER. A F/U MDR WILL BE SUBMITTED ON OR BEFORE 04/15/2011. THE DEVICE HISTORY RECORD FOR THE LOT NUMBER SAID TO BE INVOLVED WAS REVIEWED. A DISCREPANCY OR ANOMALY WAS NOT OBSERVED WITH THE PRODUCT THAT WAS RELEASED FOR DISTRIBUTION. A SAMPLE TEST FROM THIS LOT COULD NOT BE CONDUCTED BECAUSE NONE OF THE PRODUCT FROM THIS LOT REMAINED IN INVENTORY. A REVIEW OF THE 12 MONTH COMPLAINT HISTORY FOR THIS PRODUCT FAMILY WAS CONDUCTED. THIS REPORT REPRESENTS AN UNUSUAL OCCURRENCE. BASED ON THIS REVIEW, THE LIKELIHOOD OF THIS TYPE OF REPORT IS RARE. CONCLUSIONS: A DEFINITIVE CAUSE FOR THIS OBSERVATION COULD NOT BE DETERMINED BECAUSE THE ACTUAL USE CONDITIONS COULD NOT BE DUPLICATED IN THE LAB SETTING. DUE TO A VARIETY OF CLINICAL CONDITIONS SUCH AS PT ANATOMY, ENDOSCOPE POSITION OR PROGRESSION OF DISEASE STATE, WE COULD NOT REPRODUCE THE ACTUAL CONDITIONS OF PRODUCT USAGE DURING OUR LAB ANALYSIS. THIS LIMITS OUR ABILITY TO CONCLUSIVELY DETERMINE A CAUSE. TIP BREAKAGE CAN OCCUR IF THE TIP COMES INTO CONTACT WITH A HARD SURFACE DURING USE AND/OR GENERAL HANDLING. BREAKAGE OF THE PROBE TIP CAN OCCUR IF THE DISTAL END OF THE ENDOSCOPE IS DEFLECTED MORE THAN 15 DEGREES WHEN THE BIPOLAR PROBE IS ADVANCED OR WITHDRAWN FROM THE ACCESSORY CHANNEL OF THE ENDOSCOPE. THE INSTRUCTIONS FOR USE WARN THE USER NOT TO PASS THE PROBE THROUGH AN ENDOSCOPE WHOSE DISTAL END IS DEFLECTED AT AN ANGLE MORE THAN APPROX 15 DEGREES. PRIOR TO DISTRIBUTION, ALL COOK ENDOSCOPY QUICKSILVER BIPOLAR PROBES ARE SUBJECTED TO A VISUAL INSPECTION TO ENSURE DEVICE INTEGRITY. A REVIEW OF THE DEVICE HISTORY RECORD CONFIRMED THAT THE LOT SAID TO BE INVOLVED MET ALL MFG REQUIREMENTS PRIOR TO SHIPMENT. CORRECTIVE ACTION: THE COMPLAINT RISK PRIORITY NUMBER (CRPN) FOR THIS TYPE OF OCCURRENCE HAS BEEN CALCULATED BASED ON THE RATE OF OCCURRENCE AND SEVERITY OF THE OUTCOME. BASED ON THIS ACTIVITY, NO CORRECTIVE ACTION IS WARRANTED AT THIS TIME. THIS OBSERVATION REPRESENTS AN UNUSUAL OCCURRENCE. THE LIKELIHOOD OF THIS TYPE OF OCCURRENCE IS RARE. CUSTOMER QA WILL CONTINUE TO MONITOR FOR COMPLAINT TRENDS.
ON (B)(6) 2011, THE FOLLOWING INFO WAS PROVIDED TO COOK: DURING AN ENDOSCOPIC PROCEDURE, THE PHYSICIAN USED A COOK QUICKSILVER BIPOLAR COAGULATION PROBE. THE NORMAL PROTOCOL WAS FOLLOWED; HOWEVER, THE PROBE WOULD NOT WORK. THE PROBE WAS DEEMED DEFECTIVE SO ANOTHER PROBE WAS USED TO SUCCESSFULLY COMPLETE THE PROCEDURE. ON (B)(4) 2011, THE DEVICE WAS RETURNED FOR EVAL. UPON EVAL, WE CONFIRMED THE DISTAL TIP OF THE DEVICE WAS MISSING FROM THE PROBE. INFO REGARDING THE LOCATION OF THE MISSING TIP WAS REQUESTED BUT WAS NOT PROVIDED. THEREFORE, THIS REPORT IS BEING PROVIDED OUT OF AN ABUNDANCE OF CAUTION. IF ADD'L INFO IS PROVIDED; A F/U MEDWATCH REPORT WILL BE SUBMITTED.
Devices
| Seq | Brand | Generic | Product Code | Manufacturer | Model | Lot | UDI-DI |
|---|---|---|---|---|---|---|---|
| 1 | QUICKSILVER BIPOLAR COAGULATION PROBE | KNS, UNIT, ELECTROSURGICAL, ENDOSCOPIC (WITH OR WITHOUT ACCESSORIES) | KNS | WILSON-COOK MEDICAL, INC. | W2959583 |
Patients
| Seq | Age | Sex | Outcome | Treatment |
|---|---|---|---|---|
| 1 | ENDOSCOPE (UNK TYPE) |