FDA Adverse Event Malfunction Summary report: N

BABY CONTROL COSYCOT INFANT WARMER

MDR report key: 2024564 · Received March 20, 2011

Report

Report Number
9611451-2011-00174
Event Type
Malfunction
Date Received
March 20, 2011
Date of Event
February 18, 2011
Report Date
February 22, 2011
Manufacturer
FISHER & PAYKEL HEALTHCARE LIMITED
Product Code
FMT
PMA / PMN Number
K971695
Product Problem
Yes
Report Source
Manufacturer report
Reporter Location
WA, US
Reporter Occupation
BIOMEDICAL ENGINEER

Narratives

Additional Manufacturer Narrative · 1

(B)(4). SERIAL NUMBER: (B)(4), DEVICE MANUFACTURE DATE: 06/13/2005; (B)(4), 06/13/2005; (B)(4), 06/13/2005; (B)(4), 06/13/2005; (B)(4), 06/13/2005; (B)(4), 06/13/2005; (B)(4), 06/13/2005; (B)(4), 06/13/2005; (B)(4), 06/13/2005. METHOD: THE HARNESSES OF NINE IW934JEU BABY CONTROL COSYCOT INFANT WARMER WERE NOT RETURNED TO FISHER & PAYKEL HEALTHCARE (FPH) IN (B)(4) FOR INSPECTION. WE ATTEMPTED TO OBTAIN FURTHER INFORMATION REGARDING THESE COMPLAINTS BUT NO REPLY WAS RECEIVED FROM THE MEDICAL CENTER. OUR ANALYSIS IS BASED ON THE EVENT DESCRIPTIONS AND RESULTS OF PREVIOUS INVESTIGATIONS ON SIMILAR COMPLAINTS. RESULTS: THE MEDICAL CENTER IN (B)(6) REPORTED THAT THEIR NINE IW3934JEU UNITS HAD DISCOLOURED UPPER AND LOWER HARNESS CONNECTORS. CONCLUSION: THE UPPER AND LOWER HARNESSES ARE USED TO CONNECT THE HEAD UNIT TO THE CONTROL UNIT OF THE INFANT WARMER. PREVIOUS INVESTIGATIONS ON SIMILAR COMPLAINTS REVEALED THAT THE DISCOLOURED HARNESS CONNECTORS OF THE INFANT WARMERS WERE MOST LIKELY DUE TO THE ARCING THAT OCCURRED BETWEEN TWO ELECTRICAL CONTACTS, RESULTING IN CONTACT FAILURE. THE ARCING WAS MOST LIKELY DUE TO A POOR CONNECTION. ALL COMPONENTS ON THE HARNESS ASSEMBLY OF THE INFANT WARMER ARE ENCLOSED IN A SHEATH AND FIRE RATED BY (B)(4). SHOULD THE CONNECTORS COMPLETELY FAIL DURING THE OPERATION, AN AUDIBLE AND VISUAL ALARM WILL BE REGISTERED ON THE FRONT CONTROL PANEL OF THE INFANT WARMER, THEREBY ALLOWING THE HOSPITAL STAFF TIME TO ACT AND PROVIDE OTHER MEANS OF WARMING. REPLACEMENT PARTS HAVE SINCE BEEN SENT TO THE MEDICAL CENTER TO REPLACE THE DISCOLOURED HARNESS CONNECTORS.

Additional Manufacturer Narrative · 1

(B)(4). SERIAL NUMBER: (B)(4), DEVICE MANUFACTURE DATE: 06/13/2005; (B)(4), 06/13/2005; (B)(4), 06/13/2005; (B)(4), 06/13/2005; (B)(4), 06/13/2005; (B)(4), 06/13/2005; (B)(4), 06/13/2005; (B)(4), 06/13/2005; (B)(4), 06/13/2005. MANUFACTURER NARRATIVE THE AFFECTED IW934JEU BABY CONTROL COSYCOT INFANT WARMER UNITS ARE NOT EXPECTED TO BE RETURNED TO FPH FOR INSPECTION. WE ARE CURRENTLY IN THE PROCESS OF OBTAINING FURTHER INFORMATION FROM THE MEDICAL CENTER IN ORDER TO ASSIST US WITH THE ANALYSIS AND IDENTIFICATION OF A POSSIBLE ROOT CAUSE OF THE REPORTED FAULT. WE WILL PROVIDE A FOLLOW UP REPORT ONCE WE RECEIVE FURTHER INFORMATION AND HAVE COMPLETED OUR ANALYSIS.

Description of Event or Problem · 1

A MEDICAL CENTER IN (B)(6) REPORTED THAT NINE IW934JEU BABY CONTROL COSYCOT INFANT WARMER UNITS WERE BELIEVED TO HAVE DISCOLOURED UPPER AND LOWER HEAD HARNESSES. THIS WAS FOUND AFTER USE ON A PATIENT. NO PATIENT CONSEQUENCE WAS REPORTED.

Description of Event or Problem · 1

A MEDICAL CENTER IN (B)(6) REPORTED THAT NINE IW934JEU BABY CONTROL COSYCOT INFANT WARMER UNITS WERE BELIEVED TO HAVE DISCOLOURED UPPER AND LOWER HEAD HARNESSES. THIS WAS FOUND AFTER USE ON A PATIENT. NO PATIENT CONSEQUENCE WAS REPORTED.

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
1 BABY CONTROL COSYCOT INFANT WARMER FMT FMT FISHER & PAYKEL HEALTHCARE LIMITED IW934JEU

Patients

Seq Age Sex Outcome Treatment
1