FDA Adverse Event Injury Summary report: N

CARPENTIER-EDWARDS PERIMOUNT PLUS PERICARDIAL BIOPROSTHESIS

MDR report key: 2022713 · Received March 17, 2011

Report

Report Number
2015691-2011-15041
Event Type
Injury
Date Received
March 17, 2011
Date of Event
November 24, 2010
Report Date
February 16, 2011
Manufacturer
EDWARDS LIFESCIENCES
Product Code
DYE
PMA / PMN Number
P860057/S016
Adverse Event
Yes
Report Source
Manufacturer report
Reporter Location
MI, US
Reporter Occupation
OTHER

Narratives

Additional Manufacturer Narrative · 1

VEGETATIONS. DEVICE NOT RETURNED. ADDITIONAL MANUFACTURER NARRATIVE: UNFORTUNATELY, THE EDWARDS DEVICE WAS NOT RETURNED FOR ANALYSIS. THE DEVICE HISTORY RECORD (DHR) REVIEW WAS COMPLETED AND THIS DEVICE PASSED ALL MANUFACTURING AND STERILIZATION INSPECTIONS WITH NO NONCONFORMANCE. LATE PROSTHETIC VALVE ENDOCARDITIS, OCCURRING MORE THAN 60 DAYS AFTER SURGERY, IS USUALLY CAUSED BY AN INFECTION WHICH OCCURS ELSEWHERE IN THE BODY, AND THEN SEEDS THE VALVE. THE MOST FREQUENT CAUSES ARE DENTAL PROCEDURES, UROLOGICAL INFECTIONS AND INTERVENTIONS, AND INDWELLING CATHETERS. EDWARDS LIFESCIENCES HAS VALIDATED METHODS FOR STERILIZATION OF ALL DEVICES WHICH ENSURES PRODUCT STERILITY. IN THIS CASE, THE SOURCE OF THE INFECTION WAS PROVIDED AS "PROBABLY DENTAL."

Description of Event or Problem · 1

EDWARDS LIFESCIENCES MAINTAINS AN IMPLANT PATIENT REGISTRY. THIS REGISTRY IS A PATIENT TRACKING MECHANISM FOR SERIALIZED EDWARDS IMPLANTABLE DEVICES (BIOPROSTHETIC HEART VALVES AND ANNULOPLASTY RINGS), RATHER THAN A TRUE POST-MARKET SURVEILLANCE REGISTRY. THROUGH THE REGISTRY, EDWARDS IS NOTIFIED WHEN THESE DEVICES ARE IMPLANTED. IN ADDITION, PATIENT AND/OR DEVICE STATUS MAY BE REPORTED TO THE REGISTRY VIA THE IMPLANTATION DATA CARDS. THE INFORMATION IS RECEIVED FROM VARIOUS SOURCES (E.G. SURGEON, HOSPITAL, AND PATIENT FAMILY MEMBERS) AND IS NOT RECEIVED IN THE FORM OF A CONVENTIONAL "CUSTOMER COMPLAINT". THE INFORMATION REPORTED MAY OR MAY NOT BE RELATED TO THE EDWARDS DEVICE. IN THIS CASE, IT WAS REPORTED THAT THE DEVICE WAS EXPLANTED AFTER AN IMPLANT DURATION OF APPROXIMATELY 7 MONTHS. THROUGH FOLLOW-UP WITH THE HEALTH-CARE PROVIDER, IT WAS LEARNED THAT THE DEVICE WAS EXPLANTED DUE TO MITRAL VALVE ENDOCARDITIS. ACCORDING TO THE OPERATIVE REPORT, THE SURGEON APPROACHED THE VALVE THROUGH A TRANSEPTAL INCISION. THERE WERE BULKY VEGETATIONS ON THE ATRIAL SURFACE OF THE VALVE. HE THEN USED AN 11 BLADE AND EXCISED THE SEWING RING AND REMOVED ALL OF THE PLEDGETS AND SUTURE MATERIAL; FOLLOWING THIS, HE IRRIGATED WITH A SUCTION IRRIGATING DEVICE AND EXCISED ALL LOOSE DEBRIS FROM THE VALVE ANNULUS AND ALL MATERIAL THAT APPEARED NOT HEALTHY. THE VALVE WAS REPLACED WITH ANOTHER EDWARDS BIOPROSTHETIC VALVE. THE PATIENT WAS FILLED AND EASILY WEANED FROM CARDIOPULMONARY BYPASS. A TRANSESOPHAGEAL ECHOCARDIOGRAM REVEALED WELL SEATED VALVE AND WELL FUNCTIONING VALVE. PER THE SURGEON, THE REASON FOR EXPLANTING THE DEVICE WAS NOT RELATED TO A PRODUCT MALFUNCTION.

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
1 CARPENTIER-EDWARDS PERIMOUNT PLUS PERICARDIAL BIOPROSTHESIS REPLACEMENT HEART VALVE DYE EDWARDS LIFESCIENCES 6900P R-09A0121

Patients

Seq Age Sex Outcome Treatment
1 73 YR Required Intervention