TAXUS LIBERTE PACLITAXEL-ELUTING CORONARY STENT SYSTEM
Report
- Report Number
- 2134265-2011-00768
- Event Type
- Malfunction
- Date Received
- March 17, 2011
- Date of Event
- February 24, 2011
- Report Date
- February 24, 2011
- Manufacturer
- BOSTON SCIENTIFIC - MAPLE GROVE
- Product Code
- NIQ
- PMA / PMN Number
- P060008
- Product Problem
- Yes
- Report Source
- Manufacturer report
- Reporter Location
- OH, US
- Reporter Occupation
- PHYSICIAN
Narratives
AGE AT TIME OF EVENT: (B)(6). DEVICE EVALUATED BY MANUFACTURER: IT IS INDICATED THAT THE DEVICE WILL NOT BE RETURNED FOR EVALUATION; THEREFORE A FAILURE ANALYSIS OF THE COMPLAINT DEVICE COULD NOT BE COMPLETED. A REVIEW OF THE BATCH HISTORY, HISTORICAL TRENDING, AND SIMILAR COMPLAINT TRENDING REVIEW FOR THE PRODUCT FAMILY WILL BE CONDUCTED. IF THERE IS ANY FURTHER RELEVANT INFORMATION FROM THAT REVIEW, A SUPPLEMENTAL MEDWATCH WILL BE FILED. (B)(4).
(B)(4).
IT WAS REPORTED THAT DURING A STENTING TREATMENT PROCEDURE STENT DAMAGE OCCURRED. THE TARGET LESION WAS LOCATED IN THE LEFT CIRCUMFLEX ARTERY (LCX). THE PHYSICIAN ATTEMPTED TO DIRECT STENT THE LESION WITH A 2.25X32MM TAXUS LIBERTE STENT; HOWEVER, THE STENT DELIVERY SYSTEM (SDS) WAS UNABLE TO CROSS THE LESION. THE DEVICE WAS REMOVED FROM THE PATIENT AND IT WAS NOTED THAT THE STENT STRUTS WERE LIFTED. THE LESION WAS THEN PREDILATED WITH AN UNSPECIFIED BALLOON AND THE PROCEDURE WAS SUCCESSFULLY COMPLETED BY IMPLANTING A 2.5X32MM TAXUS LIBERTE STENT. NO PATIENT COMPLICATIONS WERE REPORTED AND THE PATIENT'S CURRENT CONDITION IS FINE.
IT WAS REPORTED THAT DURING A STENTING TREATMENT PROCEDURE STENT DAMAGE OCCURRED. THE TARGET LESION WAS LOCATED IN THE LEFT CIRCUMFLEX ARTERY (LCX). THE PHYSICIAN ATTEMPTED TO DIRECT STENT THE LESION WITH A 2.25X32MM TAXUS LIBERTE STENT; HOWEVER, THE STENT DELIVERY SYSTEM (SDS) WAS UNABLE TO CROSS THE LESION. THE DEVICE WAS REMOVED FROM THE PATIENT AND IT WAS NOTED THAT THE STENT STRUTS WERE LIFTED. THE LESION WAS THEN PREDILATED WITH AN UNSPECIFIED BALLOON AND THE PROCEDURE WAS SUCCESSFULLY COMPLETED BY IMPLANTING A 2.5X32MM TAXUS LIBERTE STENT. NO PATIENT COMPLICATIONS WERE REPORTED AND THE PATIENT'S CURRENT CONDITION IS FINE.
Devices
| Seq | Brand | Generic | Product Code | Manufacturer | Model | Lot | UDI-DI |
|---|---|---|---|---|---|---|---|
| 1 | TAXUS LIBERTE PACLITAXEL-ELUTING CORONARY STENT SYSTEM | CORONARY DRUG-ELUTING STENT | NIQ | BOSTON SCIENTIFIC - MAPLE GROVE | H7493893632220 | 13756957 |
Patients
| Seq | Age | Sex | Outcome | Treatment |
|---|---|---|---|---|
| 1 |