FDA Adverse Event Malfunction Summary report: N

SURE-T

MDR report key: 20198300 · Received September 12, 2024

Report

Report Number
3003442380-2024-24981
Event Type
Malfunction
Date Received
September 12, 2024
Date of Event
August 12, 2024
Report Date
November 13, 2025
Manufacturer
UNOMEDICAL A/S
Product Code
FPA
UDI-DI
05705244019348
PMA / PMN Number
K041545
Product Problem
Yes
Report Source
Manufacturer report
Reporter Location
CA, US
Reporter Occupation
003

Narratives

Additional Manufacturer Narrative · 0

ADDITIONAL INFORMATION - THIS MDR IS BEING SUBMITTED TO INCLUDE THE BELOW: H6: INVESTIGATION RESULTS UNDER TYPE OF INVESTIGATION, INVESTIGATION FINDINGS, INVESTIGATION CONCLUSIONS. H11: INVESTIGATION SUMMARY. PER REVISION 21 OF PROCEDURE (B)(4), A CHILD INVESTIGATION IS NOT REQUIRED TO DOCUMENT THE DHR REVIEW FOR A TYPE 2 REPORTABLE COMPLAINT. HOWEVER, THE CHILD WAS CREATED TO ALLOW THE PARENT RECORD TO ADVANCE TO REVIEW AND SUMMARY. SINCE IT WAS CREATED, THE DHR REVIEW WAS DOCUMENTED WITHIN THE CHILD. COMPLAINT INVESTIGATION RESULTS: A COMPLAINT INVESTIGATION HAS BEEN INITIATED UNDER COMPLAINT INVESTIGATION CHILD RECORD (B)(4). THE BATCH 6002368, IN QUESTION WAS MANUFACTURED AT THE REYNOSA SITE. DEVICE HISTORY RECORD (DHR) REVIEW: THE LOT 6002368 WAS MANUFACTURED ACCORDING TO THE WORK INSTRUCTION (WI) VERSION 96 AND PACKAGED IN THE MACHINE MULTIVAC 10 ON 28-JUL-2023, WITH A TOTAL OF (B)(4) UNITS. GLUING TUBE THE SUB-ASSEMBLY, GLUING TUBE OF THE LOT 3G02864 WAS MANUFACTURED ACCORDING TO THE WI VERSION 55 AND MANUFACTURED IN THE MACHINE SC06, ON 24-JUL-2023, WITH A TOTAL OF (B)(4) UNITS. THE SUB-ASSEMBLY, GLUING TUBE OF THE LOT 3G04188 WAS MANUFACTURED ACCORDING TO THE WI VERSION 55 AND MANUFACTURED IN THE MACHINE SC06, ON 25-JUL-2023, WITH A TOTAL OF (B)(4) UNITS. REVIEW OF THE DHR SHOWED THAT ALL RELEVANT TESTS REQUIRED DURING THE RELATED PROCESSES HAD BEEN FULFILLED AND MET THE REQUIREMENTS. NO DEVIATION WAS IDENTIFIED, NOR MAINTENANCE EVENTS WERE RECORDED RELATED TO COMPLAINT CODE. CONCLUSION SUMMARY OF COMPLAINT INVESTIGATION: NO NON-CONFORMANCE (NC) RAISED DURING PRODUCTION RELATED TO COMPLAINT CODE; NO FURTHER ACTIONS ARE REQUIRED. THIS COMPLAINT WILL NOT REQUIRE FURTHER ROOT CAUSE INVESTIGATION NOR CORRECTIVE AND PREVENTIVE ACTION (CAPA) PLAN. THEREFORE, THIS ISSUE WILL BE MONITORED THROUGH THE POST MARKET SURVEILLANCE ACTIVITIES.

Additional Manufacturer Narrative · 0

PATIENT CITY - (B)(6).

Description of Event or Problem · 0

TO DATE NO ADDITIONAL PATIENT OR EVENT DETAILS HAVE BEEN RECEIVED.

Description of Event or Problem · 0

REFERENCE NUMBER (B)(4). EVENT OCCURRED IN THE GERMANY. IT WAS REPORTED ON (B)(6) 2024 THAT INFUSION SET TUBING GOT DETACHED FROM TUBING-TUBING CONNECTOR WHICH RESULTS INTO THE REPLACEMENT OF DEVICE. THE INSERTION SITE WAS AT ABDOMEN. DURATION OF INFUSION SET USED WAS FOR 1-2 DAYS. NO FURTHER INFORMATION AVAILABLE.

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
315028 SURE-T UNO CONTACT DETACH G29 80/6 SC1 MIMX FPA UNOMEDICAL A/S MMT-866A 6002368 05705244019348

Patients

Seq Age Sex Outcome Treatment
1 NA Unknown