FDA Adverse Event Malfunction Summary report: N

PROXIS¿ URETERAL ACCESS SHEATH

MDR report key: 20135887 · Received September 4, 2024

Report

Report Number
1018233-2024-05497
Event Type
Malfunction
Date Received
September 4, 2024
Date of Event
August 7, 2024
Report Date
July 22, 2025
Manufacturer
C.R. BARD INC. (COVINGTON) -1018233
Product Code
FED
UDI-DI
00801741101694
PMA / PMN Number
K160861
Product Problem
Yes
Report Source
Manufacturer report
Reporter Location
JA
Reporter Occupation
PHYSICIAN
Health Professional
Yes

Narratives

Additional Manufacturer Narrative · 0

THE INVESTIGATION IS STILL IN PROGRESS. ONCE THE INVESTIGATION IS COMPLETE A SUPPLEMENTAL REPORT WILL BE FILED. UDI FORMAT UPDATED WITH AVAILABLE PRODUCT INFORMATION PER GUDID. H11: SECTION A THROUGH F - THE INFORMATION PROVIDED BY BD REPRESENTS ALL THE KNOWN INFORMATION AT THIS TIME. DESPITE GOOD FAITH EFFORTS TO OBTAIN ADDITIONAL INFORMATION, THE COMPLAINANT / REPORTER WAS UNABLE OR UNWILLING TO PROVIDE ANY FURTHER PATIENT, PRODUCT, OR PROCEDURAL DETAILS TO BD.

Additional Manufacturer Narrative · 0

THE REPORTED EVENT IS CONFIRMED CAUSE UNKNOWN. VISUAL EVALUATION NOTED THE SAMPLE WAS PROVIDED WITH THE ORIGINAL BARD POUCH AND BOTH WERE PLACED INSIDE A LARGE ZIPLOC BAG. VISUAL REQUIREMENTS STATE TO USE UNAIDED EYE AT 12 TO 18 DISTANCES UNDER NORMAL ROOM LIGHTING. MAJOR DEFECTS: EXCESSIVE GLUE IN THROUGH HOLE OF LOCKING MECHANISM. THE GUIDEWIRE IS TO BE 0.038. DURING THE EVALUATION OF THE SAMPLE, NO VISUAL DEFECTS WERE OBSERVED. THE 0.038 GUIDEWIRE, AS SPECIFIED IN CS-7250-XX, PASSED THROUGH THE SAMPLE SEAMLESSLY. THE COMPLAINT COULD NOT HAVE BEEN SUSTAINED, HOWEVER, IT IS BELIEVED THAT THE BLOCKAGE WAS REMOVED DUE TO MEDICONE'S EFFORT TO REMOVE IT AS INDICATED IN THE REPORT. A PHOTOGRAPH OF THE BLOCKAGE HAS BEEN PROVIDED FOR REFERENCE. THE BLOCKAGE APPEARS TO RESEMBLE THE ADHESIVE USED IN THE ASSEMBLY OF THE HUB TO THE DILATOR. NO ACTIONS CAN BE TAKEN AT THIS TIME SINCE A ROOT CAUSE WAS NOT IDENTIFIED. DHR REVIEW DID NOT SHOW ANY PROBLEMS OR CONDITIONS THAT WOULD HAVE CONTRIBUTED TO THE REPORTED EVENT. THE INSTRUCTIONS FOR USE WERE FOUND ADEQUATE AND STATE THE FOLLOWING: INSTRUCTIONS FOR USE: DESCRIPTION: THE PROXIS URETERAL ACCESS SHEATH IS A TWO COMPONENT URETERAL DILATION SYSTEM WHICH CONTAINS A SINGLE LUMEN FOR INJECTION OF FLUIDS AS WELL AS PASSAGE OF ENDOSCOPES AND RELATED INSTRUMENTS. THE PACKAGED PRODUCT INCLUDES THE FOLLOWING ITEMS: 1 HYDROPHILIC-COATED DILATOR WITH FEMALE LUER CONNECTOR. 1 HYDROPHILIC-COATED SHEATH WITH HUB. INDICATIONS FOR USE: THE PROXIS URETERAL ACCESS SHEATH IS INDICATED FOR USE IN ENDOSCOPIC UROLOGY PROCEDURES WHERE URETERAL DILATION AND URETERAL ACCESS IS DESIRED FOR INJECTION OF FLUIDS AND INSERTION AND REMOVAL OF ENDOSCOPES AND RELATED INSTRUMENTS. CONTRAINDICATIONS: PATIENTS WHO ARE CONTRAINDICATED FOR RETROGRADE UROLOGICAL PROCEDURES. PATIENTS WHO ARE CONTRAINDICATED FOR ANTEGRADE UROLOGIC PROCEDURES, INCLUDING BUT NOT LIMITED TO PATIENTS WITH BLOOD CLOTTING ANOMALIES DUE TO COAGULOPATHIES OR PHARMACOLOGICAL ANTI-COAGULATIONS. PATIENTS WHO HAVE THE PRESENCE OF TIGHT STRICTURES WHICH WOULD LIMIT USE OF THE DEVICE. PATIENTS WHO HAVE THE PRESENCE OF LARGE OBSTRUCTING DISTAL URETERAL CALCULI. WARNING: FOR SINGLE USE ONLY. DO NOT REUSE, REPROCESS OR RESTERILIZE. REUSE, REPROCESSING OR RESTERILIZATION MAY COMPROMISE THE STRUCTURAL INTEGRITY OF THE DEVICE AND/ OR LEAD TO DEVICE FAILURE, WHICH IN TURN, MAY RESULT IN PATIENT INJURY, ILLNESS OR DEATH. REUSE REPROCESSING OR RE-STERILIZATION MAY ALSO CREATE A RISK OF CONTAMINATION OF THE DEVICE AND/OR CAUSE PATIENT INFECTION OR CROSS INFECTION, INCLUDING, BUT NOT LIMITED TO, THE TRANSMISSION OF INFECTIOUS DISEASE(S) FROM ONE PATIENT TO ANOTHER. CONTAMINATION OF THE DEVICE MAY LEAD TO INJURY, ILLNESS OR DEATH OF THE PATIENT. DO NOT USE IF STERILE BARRIER IS DAMAGED. AFTER USE, THIS PRODUCT MAY BE A POTENTIAL BIOHAZARD. HANDLE AND DISPOSE OF IN ACCORDANCE WITH ACCEPTED MEDICAL PRACTICES AND WITH APPLICABLE LAWS AND REGULATIONS. CAUTION: FEDERAL (U.S.A.) LAW RESTRICTS THIS DEVICE TO SALE BY OR ON THE ORDER OF A PHYSICIAN. PRECAUTIONS: THE RECOMMENDATIONS GIVEN ARE MEANT TO SERVE ONLY AS A BASIC GUIDE TO THE UTILIZATION OF THIS ACCESS SHEATH. THE URETERAL ACCESS SHEATH SHOULD NOT BE USED WITHOUT COMPREHENSIVE KNOWLEDGE OF THE INDICATIONS, TECHNIQUES AND RISKS OF THE PROCEDURE. TO MINIMIZE RESISTANCE DURING ADVANCEMENT, ENSURE THE HYDROPHILIC COATING ON THE DILATOR AND SHEATH IS ACTIVATED WITH SALINE OR STERILE WATER PRIOR TO PLACEMENT. DO NOT ADVANCE SHEATH WITHOUT THE DILATOR IN PLACE AS THIS COULD LEAD TO TRAUMA OR INJURY TO PATIENT. DO NOT BEND THE DEVICE PRIOR TO PLACEMENT AS THIS COULD DAMAGE THE INTEGRITY OF THE DEVICE AND RESULT IN PATIENT INJURY. DO NOT ADVANCE OR WITHDRAW DEVICE IF ANY RESISTANCE IS ENCOUNTERED DURING PLACEMENT OR REMOVAL WITHOUT DETERMINING CAUSE AND TAKING ACTION. ADVERSE EVENTS POTENTIAL ADVERSE EVENTS ASSOCIATED WITH THE USE OF THE TRANSURETHRAL ACCESS DEVICE INCLUDE, BUT ARE NOT LIMITED TO: MUCOSAL IRRITATION, INFLAMMATION AND EDEMA URETHRAL STRICTURES ACUTE BLEEDING OR HEMORRHAGE URETHRAL, BLADDER, OR URETERAL PERFORATION OTHER INJURY TO THE URINARY TRACT DIRECTIONS FOR USE: 1. ACTIVATE THE HYDROPHILIC COATING BY PLACING THE DILATOR AND SHEATH COMPONENTS INTO SALINE OR STERILE WATER. PLACE AN 0.035" (0.889MM) OR 0.038" (0.965MM) GUIDEWIRE INTO THE URETER USING STANDARD ENDOUROLOGY TECHNIQUES. 2. ENSURE THE DILATOR LOCK IS SECURELY ENGAGED WITH SHEATH HUB PRIOR TO INSERTION. 3. INSERT THE GUIDEWIRE INTO THE TAPERED END OF THE DILATOR/SHEATH ASSEMBLY AND GRADUALLY ADVANCE THE ASSEMBLY INTO THE URETER. NOTE: PLACEMENT OF THE ASSEMBLY CAN BE VERIFIED USING FLUOROSCOPY OR RADIOGRAPHIC MEANS. 4. WHILE MAINTAINING SHEATH POSITION, DISENGAGE THE DILATOR LOCK FROM THE SHEATH HUB TO GENTLY REMOVE THE DILATOR. DO NOT ADVANCE SHEATH WITHOUT THE DILATOR IN PLACE. NOTE: SUTURE HOLES ARE PROVIDED ON SHEATH HUB FOR SECURING EXTERNALLY, IF DESIRED. 5. AN ENDOSCOPE AND/OR RELATED INSTRUMENTS CAN NOW BE USED THROUGH THE URETERAL SHEATH AS NEEDED. 6. IF DESIRED, IRRIGATION CAN BE APPLIED USING THE LUER CONNECTOR ON THE DILATOR. 7. UPON COMPLETION OF THE ACCESS PROCEDURE, GENTLY WITHDRAW THE DEVICE. 8. DISCARD THE DEVICE IN ACCORDANCE WITH HOSPITAL PROCEDURES AND WITH APPLICABLE LAWS AND REGULATIONS. UDI FORMAT UPDATED WITH AVAILABLE PRODUCT INFORMATION PER GUDID. H11: SECTION A THROUGH F - THE INFORMATION PROVIDED BY BD REPRESENTS ALL THE KNOWN INFORMATION AT THIS TIME. DESPITE GOOD FAITH EFFORTS TO OBTAIN ADDITIONAL INFORMATION, THE COMPLAINANT / REPORTER WAS UNABLE OR UNWILLING TO PROVIDE ANY FURTHER PATIENT, PRODUCT, OR PROCEDURAL DETAILS TO BD.

Additional Manufacturer Narrative · 0

THE REPORTED EVENT IS CONFIRMED CAUSE UNKNOWN. VISUAL EVALUATION NOTED THE SAMPLE WAS PROVIDED WITH THE ORIGINAL BARD POUCH AND BOTH WERE PLACED INSIDE A LARGE ZIPLOC BAG. NO ACTIONS CAN BE TAKEN AT THIS TIME SINCE A ROOT CAUSE WAS NOT IDENTIFIED. DHR REVIEW DID NOT SHOW ANY PROBLEMS OR CONDITIONS THAT WOULD HAVE CONTRIBUTED TO THE REPORTED EVENT. THE INSTRUCTIONS FOR USE WERE FOUND ADEQUATE AND STATE THE FOLLOWING: INSTRUCTIONS FOR USE DESCRIPTION: THE PROXIS URETERAL ACCESS SHEATH IS A TWO COMPONENT URETERAL DILATION SYSTEM WHICH CONTAINS A SINGLE LUMEN FOR INJECTION OF FLUIDS AS WELL AS PASSAGE OF ENDOSCOPES AND RELATED INSTRUMENTS. THE PACKAGED PRODUCT INCLUDES THE FOLLOWING ITEMS: 1 - HYDROPHILIC-COATED DILATOR WITH FEMALE LUER CONNECTOR 1 - HYDROPHILIC-COATED SHEATH WITH HUB INDICATIONS FOR USE: THE PROXIS URETERAL ACCESS SHEATH IS INDICATED FOR USE IN ENDOSCOPIC UROLOGY PROCEDURES WHERE URETERAL DILATION AND URETERAL ACCESS IS DESIRED FOR INJECTION OF FLUIDS AND INSERTION AND REMOVAL OF ENDOSCOPES AND RELATED INSTRUMENTS. CONTRAINDICATIONS: PATIENTS WHO ARE CONTRAINDICATED FOR RETROGRADE UROLOGICAL PROCEDURES. PATIENTS WHO ARE CONTRAINDICATED FOR ANTEGRADE UROLOGIC PROCEDURES, INCLUDING BUT NOT LIMITED TO PATIENTS WITH BLOOD CLOTTING ANOMALIES DUE TO COAGULOPATHIES OR PHARMACOLOGICAL ANTICOGAGULATIONS. PATIENTS WHO HAVE THE PRESENCE OF TIGHT STRICTURES WHICH WOULD LIMIT USE OF THE DEVICE. PATIENTS WHO HAVE THE PRESENCE OF LARGE OBSTRUCTING DISTAL URETERAL CALCULI. WARNING: FOR SINGLE USE ONLY. DO NOT REUSE, REPROCESS OR RESTERILIZE. REUSE, REPROCESSING OR RESTERILIZATION MAY COMPROMISE THE STRUCTURAL INTEGRITY OF THE DEVICE AND/ OR LEAD TO DEVICE FAILURE, WHICH IN TURN, MAY RESULT IN PATIENT INJURY, ILLNESS OR DEATH. REUSE REPROCESSING OR RE-STERILIZATION MAY ALSO CREATE A RISK OF CONTAMINATION OF THE DEVICE AND/OR CAUSE PATIENT INFECTION OR CROSSINFECTION, INCLUDING, BUT NOT LIMITED TO, THE TRANSMISSION OF INFECTIOUS DISEASE(S) FROM ONE PATIENT TO ANOTHER. CONTAMINATION OF THE DEVICE MAY LEAD TO INJURY, ILLNESS OR DEATH OF THE PATIENT. DO NOT USE IF STERILE BARRIER IS DAMAGED. AFTER USE, THIS PRODUCT MAY BE A POTENTIAL BIOHAZARD. HANDLE AND DISPOSE OF IN ACCORDANCE WITH ACCEPTED MEDICAL PRACTICES AND WITH APPLICABLE LAWS AND REGULATIONS. CAUTION: FEDERAL (U.S.A.) LAW RESTRICTS THIS DEVICE TO SALE BY OR ON THE ORDER OF A PHYSICIAN. PRECAUTIONS: THE RECOMMENDATIONS GIVEN ARE MEANT TO SERVE ONLY AS A BASIC GUIDE TO THE UTILIZATION OF THIS ACCESS SHEATH. THE URETERAL ACCESS SHEATH SHOULD NOT BE USED WITHOUT COMPREHENSIVE KNOWLEDGE OF THE INDICATIONS, TECHNIQUES AND RISKS OF THE PROCEDURE. TO MINIMIZE RESISTANCE DURING ADVANCEMENT, ENSURE THE HYDROPHILIC COATING ON THE DILATOR AND SHEATH IS ACTIVATED WITH SALINE OR STERILE WATER PRIOR TO PLACEMENT. DO NOT ADVANCE SHEATH WITHOUT THE DILATOR IN PLACE AS THIS COULD LEAD TO TRAUMA OR INJURY TO PATIENT. DO NOT BEND THE DEVICE PRIOR TO PLACEMENT AS THIS COULDDAMAGE THE INTEGRITY OF THE DEVICE AND RESULT IN PATIENT INJURY. DO NOT ADVANCE OR WITHDRAW DEVICE IF ANY RESISTANCE IS ENCOUNTERED DURING PLACEMENT OR REMOVAL WITHOUT DETERMINING CAUSE AND TAKING ACTION. ADVERSE EVENTS POTENTIAL ADVERSE EVENTS ASSOCIATED WITH THE USE OF THE TRANSURETHRAL ACCESS DEVICE INCLUDE, BUT ARE NOT LIMITED TO: - MUCOSAL IRRITATION, INFLAMMATION AND EDEMA - URETHRAL STRICTURES - ACUTE BLEEDING OR HEMORRHAGE - URETHRAL, BLADDER, OR URETERAL PERFORATION - OTHER INJURY TO THE URINARY TRACT DIRECTIONS FOR USE: 1. ACTIVATE THE HYDROPHILIC COATING BY PLACING THE DILATOR AND SHEATH COMPONENTS INTO SALINE OR STERILE WATER. PLACE AN 0.035 (0.889MM) OR 0.038 (0.965MM) GUIDEWIRE INTO THE URETER USING STANDARD ENDOUROLOGY TECHNIQUES. 2. ENSURE THE DILATOR LOCK IS SECURELY ENGAGED WITH SHEATH HUB PRIOR TO INSERTION. 3. INSERT THE GUIDEWIRE INTO THE TAPERED END OF THE DILATOR/SHEATH ASSEMBLY AND GRADUALLY ADVANCE THE ASSEMBLY INTO THE URETER. NOTE: PLACEMENT OF THE ASSEMBLY CAN BE VERIFIED USING FLUOROSCOPY OR RADIOGRAPHIC MEANS. 4. WHILE MAINTAINING SHEATH POSITION, DISENGAGE THE DILATOR LOCK FROM THE SHEATH HUB TO GENTLY REMOVE THE DILATOR. DO NOT ADVANCE SHEATH WITHOUT THE DILATOR IN PLACE. NOTE: SUTURE HOLES ARE PROVIDED ON SHEATH HUB FOR SECURING EXTERNALLY, IF DESIRED. 5. AN ENDOSCOPE AND/OR RELATED INSTRUMENTS CAN NOW BE USED THROUGH THE URETERAL SHEATH AS NEEDED. 6. IF DESIRED, IRRIGATION CAN BE APPLIED USING THE LUER CONNECTOR ON THE DILATOR. 7. UPON COMPLETION OF THE ACCESS PROCEDURE, GENTLY WITHDRAW THE DEVICE. 8. DISCARD THE DEVICE IN ACCORDANCE WITH HOSPITAL PROCEDURES AND WITH APPLICABLE LAWS AND REGULATIONS CORRECTION: D, H UDI FORMAT UPDATED WITH AVAILABLE PRODUCT INFORMATION PER GUDID. H11: SECTION A THROUGH F - THE INFORMATION PROVIDED BY BD REPRESENTS ALL THE KNOWN INFORMATION AT THIS TIME. DESPITE GOOD FAITH EFFORTS TO OBTAIN ADDITIONAL INFORMATION, THE COMPLAINANT / REPORTER WAS UNABLE OR UNWILLING TO PROVIDE ANY FURTHER PATIENT, PRODUCT, OR PROCEDURAL DETAILS TO BD.

Description of Event or Problem · 0

IT WAS REPORTED THAT THERE HAD BEEN MANY CASES WHERE GUIDEWIRE HAD NOT BEEN ABLE TO PASS DUE TO ADHESIVE-LIKE MATERIAL REMAINING BETWEEN THE HUB PART OF THE DILATOR AND THE CONNECTION PART OF THE GRAY DILATOR. IT OFTEN PASSES IF PRESSED IT HARD MANY TIMES, AND MEDICON CLAIM THAT THIS WAS A MEDICAL PROBLEM. THEY WERE ALSO COLLECTING THE ADHESIVE-LIKE MATERIAL THAT CAME OUT. ALTHOUGH THE ITEM SENT THIS TIME HAD BEEN RELEASED, SIMILAR CASES WERE OCCURRING CONTINUOUSLY. LOT#BMJRFM14 AND LOT#UNK.

Description of Event or Problem · 0

IT WAS REPORTED THAT THERE HAD BEEN MANY CASES WHERE GUIDEWIRE HAD NOT BEEN ABLE TO PASS DUE TO ADHESIVE-LIKE MATERIAL REMAINING BETWEEN THE HUB PART OF THE DILATOR AND THE CONNECTION PART OF THE GRAY DILATOR. IT OFTEN PASSES IF PRESSED IT HARD MANY TIMES, AND MEDICON CLAIM THAT THIS WAS A MEDICAL PROBLEM. THEY WERE ALSO COLLECTING THE ADHESIVE-LIKE MATERIAL THAT CAME OUT. ALTHOUGH THE ITEM SENT THIS TIME HAD BEEN RELEASED, SIMILAR CASES WERE OCCURRING CONTINUOUSLY. LOT#: BMJRFM14 AND LOT#: UNK.

Description of Event or Problem · 0

IT WAS REPORTED THAT THERE HAD BEEN MANY CASES WHERE GUIDEWIRE HAD NOT BEEN ABLE TO PASS DUE TO ADHESIVE-LIKE MATERIAL REMAINING BETWEEN THE HUB PART OF THE DILATOR AND THE CONNECTION PART OF THE GRAY DILATOR. IT OFTEN PASSES IF PRESSED IT HARD MANY TIMES, AND MEDICON CLAIM THAT THIS WAS A MEDICAL PROBLEM. THEY WERE ALSO COLLECTING THE ADHESIVE-LIKE MATERIAL THAT CAME OUT. ALTHOUGH THE ITEM SENT THIS TIME HAD BEEN RELEASED, SIMILAR CASES WERE OCCURRING CONTINUOUSLY. LOT#BMJRFM14 AND LOT#UNK.

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
1081029 PROXIS¿ URETERAL ACCESS SHEATH URETERAL ACCESS SHEATH FED C.R. BARD INC. (COVINGTON) -1018233 BMJRFM14 00801741101694

Patients

Seq Age Sex Outcome Treatment
1 NA Unknown Other