FDA Adverse Event Malfunction Summary report: N

BIOFIRE® BLOOD CULTURE IDENTIFICATION 2 (BCID2) PANEL

MDR report key: 20101299 · Received August 29, 2024

Report

Report Number
3002773840-2024-00377
Event Type
Malfunction
Date Received
August 29, 2024
Report Date
August 29, 2024
Manufacturer
BIOFIRE DIAGNOSTICS, LLC
Product Code
PAM
PMA / PMN Number
K193519
Product Problem
Yes
Report Source
Manufacturer report
Reporter Location
TW
Reporter Occupation
OTHER HEALTH CARE PROFESSIONAL
Health Professional
Yes

Narratives

Additional Manufacturer Narrative · 0

INVESTIGATION: A FALSE POSITIVE C. TROPICALIS RESULT ON THE BIOFIRE BLOOD CULTURE IDENTIFICATION 2 (BCID2) PANEL WAS ALLEGED IN A PUBLICATION TITLED "THE REAL-WORLD IMPACT OF THE BIOFIRE FILMARRAY BLOOD CULTURE IDENTIFICATION 2 PANEL ON ANTIMICROBIAL STEWARDSHIP AMONG PATIENTS WITH BLOOD STREAM INFECTIONS IN INTENSIVE CARE UNITS WITH A HIGH BURDEN OF DRUG-RESISTANT PATHOGENS" BY HSU-YUAN CHEN ET AL. THE AUTHOR OF THE STUDY CONFIRMED UPON FOLLOW-UP THAT PATIENT CARE WAS NOT AFFECTED DUE TO THE BIOFIRE BCID2 PANEL RESULT. NO SERIOUS INJURY OR DEATH WAS REPORTED. REFERENCE: CHEN, H. Y., TSENG, H. Y., CHEN, C. L., LIN, Y. C., LIANG, S. J., TU, C. Y., CHEN, W. C., & HSUEH, P. R. (2024). THE REAL-WORLD IMPACT OF THE BIOFIRE FILMARRAY BLOOD CULTURE IDENTIFICATION 2 PANEL ON ANTIMICROBIAL STEWARDSHIP AMONG PATIENTS WITH BLOODSTREAM INFECTIONS IN INTENSIVE CARE UNITS WITH A HIGH BURDEN OF DRUG-RESISTANT PATHOGENS. JOURNAL OF MICROBIOLOGY, IMMUNOLOGY, AND INFECTION = WEI MIAN YU GAN RAN ZA ZHI, 57(4), 580-593. HTTPS://DOI.ORG/10.1016/J.JMII.2024.06.004 CONCLUSION: THE INVESTIGATION DETERMINED THAT THE MOST LIKELY CAUSE OF THE DISCREPANT C. TROPICALIS RESULT WAS THE PRESENCE OF NON-VIABLE ORGANISM/NUCLEIC ACID IN THE BLOOD CULTURE MEDIA BOTTLE. SIMILAR EVENTS WERE OBSERVED IN THE FIELD WITH THE COMBINATION OF THE BIOFIRE BCID2 PANEL AND BD BACTEC¿ BLOOD CULTURE BOTTLES. A FIELD SAFETY CORRECTIVE ACTION (FSCA) WAS ISSUED IN THE U.S. ON JANUARY 26, 2024, AND COUNTRIES OUTSIDE U.S. ON JANUARY 30, 2024, VIA FSCA #5811 FOR THIS ISSUE. WHILE BLOOD CULTURE VIALS ARE AUTOCLAVED AND ROUTINELY QUALITY CONTROLLED FOR STERILITY, NON-VIABLE ORGANISMS OR NUCLEIC ACIDS CAN REMAIN IN THE BLOOD CULTURE MEDIA AFTER THE STERILIZATION PROCESS. THE PRESENCE OF NON-VIABLE ORGANISMS AND NUCLEIC ACID DOES NOT COMPROMISE THE INTENDED USE OF BLOOD CULTURE MEDIA, CULTURING VIABLE MICROORGANISMS; HOWEVER, THE BIOFIRE BCID2 PANEL DOES NOT DISTINGUISH BETWEEN NUCLEIC ACID FROM VIABLE OR NON-VIABLE ORGANISMS. THE "LABORATORY PRECAUTION" AND "LIMITATION" SECTIONS OF THE BIOFIRE BCID2 PANEL INSTRUCTIONS FOR USE (IFU) (WWW.ONLINE-IFU.COM/ITI0048) OUTLINES THE POTENTIAL FOR FALSE POSITIVE DETECTIONS DURING MOLECULAR TESTING WITH STERILE BLOOD CULTURE MEDIA CONTAINING DETECTABLE LEVELS OF NON-VIABLE ORGANISMS AND/OR NUCLEIC ACID. IMPORTANTLY, RESULTS FROM THE BIOFIRE BCID2 PANEL ARE INTENDED TO BE CORRELATED WITH THE CLINICAL HISTORY, EPIDEMIOLOGICAL DATA, AND OTHER DATA AVAILABLE TO THE CLINICIAN EVALUATING THE PATIENT. ALL IDENTIFICATION RESULTS PROVIDED BY THE BIOFIRE BCID2 PANEL ARE INTENDED TO BE INTERPRETED IN CONJUNCTION WITH GRAM STAIN RESULTS. CLINICAL PERFORMANCE: ACCORDING TO TABLE 38. BIOFIRE BCID2 PANEL CLINICAL PERFORMANCE SUMMARY, CANDIDA SPP. OF THE BIOFIRE BCID2 PANEL IFU, THE PERFORMANCE CLAIM FOR THE C. TROPICALIS ASSAY COMPARED TO STANDARD OF CARE IDENTIFICATION FOR GENUS LEVEL FOLLOWED BY PCR & SEQUENCING OF ISOLATES FOR SPECIES IDENTIFICATION SHOWED AN OVERALL SENSITIVITY OF 100% (95% CI 93.5-100%) AND AN OVERALL SPECIFICITY OF 99.9% (95% CI 99.7-100%). THE SINGLE FALSE POSITIVE SPECIMEN WAS IDENTIFIED AS A CROSS-REACTIVITY BETWEEN THE BIOFIRE BCID2 PANEL C. TROPICALIS ASSAY AND HIGH TITER CANDIDA PARAPSILOSIS. THIS CROSS-REACTIVITY IS A KNOWN LIMITATION OF THE BIOFIRE BCID2 PANEL.

Description of Event or Problem · 0

SUMMARY: A FALSE POSITIVE C. TROPICALIS RESULT ON THE BIOFIRE BLOOD CULTURE IDENTIFICATION 2 (BCID2) PANEL WAS ALLEGED IN A PUBLICATION TITLED "THE REAL-WORLD IMPACT OF THE BIOFIRE FILMARRAY BLOOD CULTURE IDENTIFICATION 2 PANEL ON ANTIMICROBIAL STEWARDSHIP AMONG PATIENTS WITH BLOOD STREAM INFECTIONS IN INTENSIVE CARE UNITS WITH A HIGH BURDEN OF DRUG-RESISTANT PATHOGENS" BY HSU-YUAN CHEN ET AL. THE AUTHOR OF THE STUDY CONFIRMED UPON FOLLOW-UP THAT PATIENT CARE WAS NOT AFFECTED DUE TO THE BIOFIRE BCID2 PANEL RESULT. THE INVESTIGATION DETERMINED THAT THE MOST LIKELY CAUSE OF THE DISCREPANT C. TROPICALIS RESULT WAS THE PRESENCE OF NON-VIABLE ORGANISM/NUCLEIC ACID IN THE BLOOD CULTURE MEDIA BOTTLE.

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
1794462 BIOFIRE® BLOOD CULTURE IDENTIFICATION 2 (BCID2) PANEL BIOFIRE® BLOOD CULTURE IDENTIFICATION 2 (BCID2) PANEL PAM BIOFIRE DIAGNOSTICS, LLC RFIT-ASY-0147

Patients

Seq Age Sex Outcome Treatment
1 NA Unknown