FDA Adverse Event Injury Summary report: N

NURSE ASSIST, LLC

MDR report key: 20091399 · Received August 28, 2024

Report

Report Number
3002695476-2024-00048
Event Type
Injury
Date Received
August 28, 2024
Date of Event
March 1, 2024
Report Date
August 6, 2024
Manufacturer
NURSE ASSIST, LLC
Product Code
FRO
UDI-DI
00612479199545
PMA / PMN Number
K083042
Adverse Event
Yes
Report Source
Manufacturer report
Reporter Location
US
Reporter Occupation
003

Narratives

Additional Manufacturer Narrative · 0

A FOLLOW-UP EMAIL WAS SENT TO MCKESSON COMPLAINTS DEPARTMENT ON 06-AUG-2024 REQUESTING ADDITIONAL INFORMATION TO AID WITH REPORTING AND WITH THE INVESTIGATION.

Description of Event or Problem · 0

DESCRIPTION OF EMAIL RECEIVED FROM COMPLAINT: (B)(6) UTILIZED MCKESSON'S NORMAL SALINE ISOTONIC IRRIGATION SOLUTION ON A LYMPHEDEMA WOUND IN (B)(6) 2024. (B)(6) WOUND BECAME INFECTED AND SHE WAS ULTIMATELY DIAGNOSED WITH A VIBRIO VULNIFICUS BACTERIAL INFECTION. (B)(6) CLAIMS THAT AS A DIRECT AND PROXIMATE RESULT OF CONTAMINATED PRODUCT SHE WAS PLACED WITH A PERIPHERALLY INSERTED CENTRAL CATHETER FOR MULTIPLE ANTIBIOTIC TREATMENT AND CONTINUES TO RECEIVE FOLLOW UP CARE THEREAFTER.

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
191076 NURSE ASSIST, LLC 0.9% NORMAL SALINE FOR IRRIGATION USP IN SCREW TOP FRO NURSE ASSIST, LLC 37-6240 23086267 00612479199545

Patients

Seq Age Sex Outcome Treatment
1 NA Unknown Hospitalization