MINIMED QUICK-SET
Report
- Report Number
- 3003442380-2024-22620
- Event Type
- Malfunction
- Date Received
- August 26, 2024
- Date of Event
- July 26, 2024
- Report Date
- November 14, 2024
- Manufacturer
- UNOMEDICAL A/S
- Product Code
- FPA
- UDI-DI
- 05705244019492
- PMA / PMN Number
- K160648
- Product Problem
- Yes
- Report Source
- Manufacturer report
- Reporter Location
- CA, US
- Reporter Occupation
- 003
Narratives
INITIAL AND FINAL MDR 1951722 - DEVICE 7 OF 10. E1: (B)(6).
SUPPLEMENTAL REPORT 01 - MDR (B)(4) - MDR 3003442380-2024-22620. ADDITIONAL INFORMATION - THIS MDR IS BEING SUBMITTED TO INCLUDE THE BELOW: H6: INVESTIGATION RESULTS UNDER TYPE OF INVESTIGATION, INVESTIGATION FINDINGS, INVESTIGATION CONCLUSIONS. H11: INVESTIGATION SUMMARY: THE INVESTIGATION ASSOCIATED WITH RELATED EVENT (B)(4) HAS BEEN APPROVED AND IS COMPLETE. NO ADDITIONAL ACTION IS REQUIRED, AND THIS COMPLAINT WILL BE CLOSED. THIS ISSUE WILL BE MONITORED THROUGH THE POST MARKETING SURVELLIENCE (PMS) PRODUCT TRENDS AND MALFUNCTION ACCORDING TO THE MARKET QUALITY REVIEW (OMQR) PROCEDURE. THE IDENTIFIED MALFUNCTION CODE, "TUBING IS DAMAGED (E.G. KINKED, DEFORMED, TWISTED, COLLAPSED OR PINCHED)", IS NOT ASSOCIATED WITH A DESIGN OR MANUFACTURING-RELATED COMPLAINT ISSUE. THEREFORE, A DETAILED INVESTIGATION OR INSPECTION OF REFERENCE SAMPLES IS NOT REQUIRED. BATCH REVIEW: LOT 6002303 WAS MANUFACTURED ON 18-AUG-2023, IN MACHINE 10, WITH A TOTAL OF (B)(4). THE BATCH RECORD WAS REVIEWED TO VERIFY IF ALL THE APPLICABLE PROCEDURES WERE FOLLOWED, AND NO ISSUES WERE FOUND. REVIEW OF THE BATCH RECORD SHOWED THAT ALL RELEVANT TESTS REQUIRED DURING THE MANUFACTURING PROCESS AND FINAL PRODUCT RELEASE HAD BEEN FULFILLED AND MET THE REQUIREMENTS. NO DISCREPANCY RELATED TO THIS ISSUE WAS FOUND WITHIN THE DOCUMENTATION. CONCLUSION SUMMARY OF THE RELATED EVENT: DUE TO THE FOLLOWING BATCH RECORD REVIEW YIELDING NO DISCREPANCIES AND NO NON-CONFORMANCE (NC) WAS GENERATED DURING PRODUCTION. IN THE MANUFACTURING PROCESS THE TUBING IS INSPECTED AGAINST SPECIFICATIONS BEFORE RELEASED FOR PRODUCTION. HOWEVER, DURING USE COULD ALSO ACCIDENTALLY KINK THE TUBING BY WINDING IT OR GETTING THE TUBING CAUGHT ON OR IN SOMETHING. NO FURTHER ACTION IS REQUIRED FOR THIS COMPLAINT.
REFERENCE NUMBER (B)(4). EVENT OCCURRED IN THE UNITED STATES. IT WAS REPORTED THAT THE PATIENT FACED AN EVENT WHERE THE TUBING KINKED AT THE CONNECTOR BETWEEN THE TUBING AND RESERVOIR PROMPTING PATIENT TO CHANGE THE SET. PATIENT CONFIRMED TO BE DRIVING WHEN SHE DISCOVERED THERE WAS A PROBLEM. NO FURTHER INFORMATION AVAILABLE.
TO DATE NO ADDITIONAL PATIENT OR EVENT DETAILS HAVE BEEN RECEIVED.
Devices
| Seq | Brand | Generic | Product Code | Manufacturer | Model | Lot | UDI-DI |
|---|---|---|---|---|---|---|---|
| 969108 | MINIMED QUICK-SET | UNO COMFORT SHORT 46/13 SC1 MINI | FPA | UNOMEDICAL A/S | MMT-368A | 6002303 | 05705244019492 |
Patients
| Seq | Age | Sex | Outcome | Treatment |
|---|---|---|---|---|
| 1 | NA | Unknown |