HARMONIC ACE 5MM SHEAR
Report
- Report Number
- 3005075853-2024-06210
- Event Type
- Injury
- Date Received
- August 22, 2024
- Date of Event
- January 1, 2024
- Report Date
- August 22, 2024
- Manufacturer
- ETHICON ENDO-SURGERY, LLC.
- Product Code
- LFL
- PMA / PMN Number
- K120729
- Adverse Event
- Yes
- Product Problem
- Yes
- Report Source
- Manufacturer report
- Reporter Location
- IN
- Reporter Occupation
- OTHER
Narratives
(B)(4). DATE SENT: 8/22/2024 B3: PUBLICATION YEAR OF 2024 D4 BATCH #: UNKNOWN D4: UDI: AS THE CATALOG/MODEL NUMBER WAS NOT PROVIDED, THE (01)GTIN IS NOT AVAILABLE. THIS REPORT IS RELATED TO A JOURNAL ARTICLE; THEREFORE, NO PRODUCT WILL BE RETURNED FOR ANALYSIS AND THE MANUFACTURING RECORDS CANNOT BE REVIEWED AS THE LOT/BATCH NUMBER HAS NOT BEEN PROVIDED. AS PART OF OUR COMPANY QUALITY SYSTEM PROCESS, ALL DEVICES ARE MANUFACTURED, INSPECTED, AND DISTRIBUTED TO APPROVED SPECIFICATIONS. THIS REPORT IS BEING SUBMITTED PURSUANT TO THE PROVISIONS OF 21 CFR, PART 803. THIS REPORT MAY BE BASED ON INFORMATION WHICH HAS NOT BEEN INVESTIGATED OR VERIFIED PRIOR TO THE REQUIRED REPORTING DATE. THIS REPORT DOES NOT REFLECT A CONCLUSION BY ETHICON, OR ITS EMPLOYEES THAT THE REPORT CONSTITUTES AN ADMISSION THAT THE PRODUCT, ETHICON, OR ITS EMPLOYEES CAUSED OR CONTRIBUTED TO THE POTENTIAL EVENT DESCRIBED IN THIS REPORT. IF INFORMATION IS OBTAINED THAT WAS NOT AVAILABLE FOR THE INITIAL REPORT, A FOLLOW-UP REPORT WILL BE FILED AS APPROPRIATE.
TITLE: ASSESSMENT OF HARMONIC SCALPEL VERSUS MONOPOLAR ELECTROCAUTERIZATION IN CHOLECYSTECTOMY AUTHORS: RAVI RANJAN, ET AL. CITATION: INTERNATIONAL JOURNAL OF LIFE SCIENCES, BIOTECHNOLOGY AND PHARMA RESEARCH VOL 13, NO 6. 2024 THE PRESENT STUDY WAS CONDUCTED TO COMPARE HARMONIC SCALPEL VERSUS MONOPOLAR ELECTROCAUTERIZATION IN CHOLECYSTECTOMY. BETWEEN AUGUST 2021 TO AUGUST 2023, 70 PATIENTS AGED 20 ¿70 YEARS; PHYSICAL STATUS CLASS I OR II, ACCORDING TO AMERICAN SOCIETY OF ANESTHESIOLOGISTS (ASA) DIAGNOSED WITH SIMPLE ACUTE OR CHRONIC CHOLECYSTITIS, CHOLELITHIASIS, SCHEDULED FOR LC WERE DIVIDED INTO 2 GROUPS OF 35 EACH. GROUP I PATIENTS UNDERWENT HARMONIC SCALPEL AND GROUP II CONVENTIONAL MONOPOLAR ELECTROCAUTERY. PARAMETERS SUCH AS OPERATIVE TIME, BLOOD LOSS, CONVERSION TO LAPAROTOMY, POSTOPERATIVE HOSPITAL STAY, POST-LC PAIN ETC. WERE RECORDED. REPORTED COMPLICATIONS INCLUDE UNKNOWN EVENT (N=2) REQUIRING CONVERSIONS TO LAPAROTOMY. IN CONCLUSION, FOR THE TREATMENT OF SIMPLE CHOLECYSTITIS AND CHOLELITHIASIS, LAPAROSCOPIC CHOLECYSTECTOMY UTILIZING TRADITIONAL MONOPOLAR ELECTROCAUTERY IS EQUALLY SAFE AND EFFECTIVE AS USING THE HARMONIC SCALPEL.
Devices
| Seq | Brand | Generic | Product Code | Manufacturer | Model | Lot | UDI-DI |
|---|---|---|---|---|---|---|---|
| 1257616 | HARMONIC ACE 5MM SHEAR | INSTRUMENT, ULTRASONIC SURGICAL | LFL | ETHICON ENDO-SURGERY, LLC. |
Patients
| Seq | Age | Sex | Outcome | Treatment |
|---|---|---|---|---|
| 1 | NA | Unknown | Required Intervention |