ONE TOUCH PING GLUCOSE MANAGEMENT SYSTEM
Report
- Report Number
- 2531779-2011-00883
- Event Type
- Injury
- Date Received
- February 16, 2011
- Date of Event
- January 17, 2011
- Report Date
- January 17, 2011
- Manufacturer
- ANIMAS CORP.
- Product Code
- LZG
- PMA / PMN Number
- K080639
- Adverse Event
- Yes
- Report Source
- Manufacturer report
- Reporter Location
- MD, US
- Reporter Occupation
- OTHER
Narratives
A FAMILY MEMBER NOTED THAT THE BATTERY COMPARTMENT AND CAP WERE UNDAMAGED; SHE ALSO REPORTED THAT THE BATTERY CAP WAS ABOUT NINE MONTHS OLD. REVIEW OF ORDERS CONFIRMED THAT THE MOST RECENT SHIPMENT OF A REPLACEMENT BATTERY CAP WAS ON (B)(6) 2009. AT THAT TIME THE ACTIVITY NOTES INDICATED THAT A FAMILY MEMBER ORDERED THE CAP AS A SPARE TO BE SUED WHEN THE CURRENT CAP HAD EXPIRED. THIS EVIDENCE INDICATES THAT THE CAP MAY HAVE BEEN OLDER THAN NINE MONTHS. THE OWNER'S BOOKLET ADVISES PUMP USERS TO REPLACE THE BATTERY CAP EVERY SIX MONTHS OR MORE FREQUENTLY IF IT IS FREQUENTLY EXPOSED TO WATER OR DUST. THE PUMP WAS RETURNED TO ANIMAS EVALUATION. STRIPPED THREADS WERE OBSERVED ON THE BATTERY CAP THAT WAS RETURNED WITH THE PUMP. EVALUATION REVEALED THIS CAP WAS UNABLE TO FULLY TIGHTEN AND EASILY DETACHED FROM THE PUMP. INVESTIGATION REVEALED AN INTERMITTENT LOSS OF CONTACT BETWEEN THE BATTERY CAP AND THE PUMP CASE. USING A TEST CAP, THE PUMP WAS EXERCISED FOR 48 HOURS WITH NO POWER LOSS. NO INTERNAL POWER RELATED DEFECTS WERE FOUND. THE BLACK BOX VERIFIED A POWER INTERRUPTION ON (B)(6) 2011, AT 9:37 PM THAT WAS NOT RESUMED BY THE USER UNTIL (B)(6) 2011 AT 7:48 AM.
IT WAS REPORTED THAT THE PT HAD BLOOD GLUCOSE OF 497 MG/DL AND WAS POSITIVE FOR KETONES WITH NO OTHER SYMPTOMS OF HYPERGLYCEMIA. A FAMILY MEMBER STATED THAT THE PUMP POWERED OFF WHILE THE PT SLEPT. SHE OBSERVED THAT THE DISPLAY SCREEN WAS BLANK AND THE PUMP HAD NO POWER; SHE NOTED THAT THE EVENT IS THE SECOND INSTANCE OF A SPONTANEOUS POWER LOSS. THE FAMILY MEMBER CHANGED THE BATTERY AND THE PUMP POWERED ON AS EXPECTED. THERE WERE NO ASSOCIATED ALARMS IN HISTORY. SHE STATED THAT THE BATTERY CAP WAS SECURE AND INTACT, THERE WAS NO YELLOW O-RING VISIBLE, AND THE BATTERY CAP WAS ABOUT 9 MONTHS OLD. THE FAMILY MEMBER SAID THAT THE BATTERY COMPARTMENT THREADS ARE INTACT AND THERE ARE NO CRACKS IN CASING. SHE CONFIRMED THAT THE BATTERY CAP WAS SECURE AND THE YELLOW O-RING WAS NOT VISIBLE AT THE TIME OF THE POWER LOSS.
Devices
| Seq | Brand | Generic | Product Code | Manufacturer | Model | Lot | UDI-DI |
|---|---|---|---|---|---|---|---|
| 1 | ONE TOUCH PING GLUCOSE MANAGEMENT SYSTEM | INSULIN INFUSION PUMP | LZG | ANIMAS CORP. | ONE TOUCH PING |
Patients
| Seq | Age | Sex | Outcome | Treatment |
|---|---|---|---|---|
| 1 | 11 YR | Required Intervention |