CARPENTIER-EDWARDS PERIMOUNT MAGNA MITRAL PERICARDIAL BIOPROSTHESIS
Report
- Report Number
- 2015691-2011-14878
- Event Type
- Injury
- Date Received
- February 24, 2011
- Date of Event
- October 19, 2010
- Report Date
- January 26, 2011
- Manufacturer
- EDWARDS LIFESCIENCES
- Product Code
- DYE
- PMA / PMN Number
- P860057/S029
- Adverse Event
- Yes
- Report Source
- Manufacturer report
- Reporter Location
- LA, US
- Reporter Occupation
- PHYSICIAN
Narratives
DEVICE NOT RETURNED. ADDITIONAL MANUFACTURER NARRATIVE: DESPITE REPEATED ATTEMPTS TO RECEIVE FURTHER INFORMATION REGARDING THE DEVICE AND EVENT, NO ADDITIONAL INFORMATION OR SAMPLE FOR EVALUATION WAS RECEIVED. THE DEVICE HISTORY RECORD (DHR) REVIEW IS CURRENTLY IN PROCESS.
ON (B)(6) 2011, THROUGH FOLLOW-UP WITH THE HEALTH-CARE PROVIDER, IT WAS LEARNED THAT THE DEVICE WAS EXPLANT DUE TO A SUTURE LOOP. ACCORDING TO THE EDWARDS DATABASE, THE VALVE WAS REPLACED WITH ANOTHER EDWARDS VALVE OF THE SAME MODEL AND SIZE. PER THE SURGEON, THE REASON FOR EXPLANTING THE DEVICE WAS PROCEDURE RELATED AND NOT DUE TO A DEVICE MALFUNCTION. THE DEVICE HISTORY RECORD (DHR) REVIEW WAS COMPLETED AND THERE WAS NO NONCONFORMANCE FOUND RELATED TO THIS EVENT. SUTURE LOOPS OCCUR WHEN A SUTURE IS CAUGHT ON THE STENT POST OR COMMISSURE AND PREVENTS THE LEAFLETS OF A BIOPROSTHETIC HEART VALVE FROM FUNCTIONING PROPERLY. THIS OCCURS DUE TO IMPROPER TECHNIQUE OR POOR VISUALIZATION OF THE VALVE DURING IMPLANTATION, AND IS NOT A MALFUNCTION OF THE DEVICE. IN MILD CASES, IT MAY GO UNDETECTED AND MAY CAUSE MILD REGURGITATION. IN OTHER CASES, SEVERE REGURGITATION MAY RESULT WHICH MAY BE DETECTED DURING THE PROCEDURE OR AT SOME LATER TIME DURING THE POST-OPERATIVE PERIOD, WHICH MAY REQUIRE REOPERATION. EDWARDS' VALVES HAVE A SPECIALIZED HOLDER DESIGNED TO PREVENT OR MINIMIZE SUTURE LOOPING. THE INSTRUCTIONS FOR USE (IFU) CONTAIN THE FOLLOWING CAUTION STATEMENT: CAUTION: AVOID LOOPING OR CATCHING A SUTURE AROUND THE OPEN CAGES, FREE STRUTS OR COMMISSURE SUPPORTS OF THE VALVE WHICH WOULD INTERFERE WITH PROPER VALVULAR FUNCTION. THE IFU FURTHER INSTRUCTS THE SURGEON ON HOW TO AVOID SUTURE LOOPING.
EDWARDS LIFESCIENCES MAINTAINS AN IMPLANT PATIENT REGISTRY. THIS REGISTRY IS A PATIENT TRACKING MECHANISM FOR SERIALIZED EDWARDS IMPLANTABLE DEVICES (BIOPROSTHETIC HEART VALVES AND ANNULOPLASTY RINGS), RATHER THAN A TRUE POST-MARKET SURVEILLANCE REGISTRY. THROUGH THE REGISTRY, EDWARDS IS NOTIFIED WHEN THESE DEVICES ARE IMPLANTED. IN ADDITION, PATIENT AND/OR DEVICE STATUS MAY BE REPORTED TO THE REGISTRY VIA THE IMPLANTATION DATA CARDS. THE INFORMATION IS RECEIVED FROM VARIOUS SOURCES (E.G. SURGEON, HOSPITAL, AND PATIENT FAMILY MEMBERS) AND IS NOT RECEIVED IN THE FORM OF A CONVENTIONAL "CUSTOMER COMPLAINT". THE INFORMATION REPORTED MAY OR MAY NOT BE RELATED TO THE EDWARDS DEVICE. IN THIS CASE, IT WAS REPORTED THAT THE DEVICE WAS EXPLANTED AFTER AN IMPLANT DURATION OF ZERO DAYS. THE REASON FOR EXPLANTING THE DEVICE WAS NOT PROVIDED. NO FURTHER DETAILS WERE REPORTED.
Devices
| Seq | Brand | Generic | Product Code | Manufacturer | Model | Lot | UDI-DI |
|---|---|---|---|---|---|---|---|
| 1 | CARPENTIER-EDWARDS PERIMOUNT MAGNA MITRAL PERICARDIAL BIOPROSTHESIS | REPLACEMENT HEART VALVE | DYE | EDWARDS LIFESCIENCES | 7000TFX | R-10D0909 |
Patients
| Seq | Age | Sex | Outcome | Treatment |
|---|---|---|---|---|
| 1 | 22 YR | Required Intervention |