CYSTOTOME CYSTOENTEROSTOMY NEEDLE KNIFE
Report
- Report Number
- 3001845648-2024-00471
- Event Type
- Malfunction
- Date Received
- August 14, 2024
- Date of Event
- October 17, 2022
- Report Date
- August 14, 2024
- Manufacturer
- COOK IRELAND LTD
- Product Code
- KNS
- PMA / PMN Number
- K022595
- Product Problem
- Yes
- Report Source
- Manufacturer report
- Reporter Location
- GR
- Reporter Occupation
- OTHER
- Health Professional
- N
Narratives
INVESTIGATION IS STILL PENDING, A FOLLOW UP MDR WILL BE SUBMITTED TO INCLUDE THE INVESTIGATION CONCLUSIONS.
CANCELLATION REPORT IS BEING SUBMITTED DUE TO THE COMPLETION OF THE INVESTIGATION ON 14-AUG-2024. INITIAL MDR REPORT GENERATED AND SUBMITTED IN ERROR. CANCELLATION REPORT SCHEDULED FOR SUBMISSION AS THE REPORT HAS BEEN SUBMITTED UNDER PR (B)(4).
(B)(4) 2022 ¿ EFFICACY AND SAFETY OF ENDOSCOPIC DRAINAGE OF PERIPANCREATIC FLUID COLLECTIONS: A RETROSPECTIVE MULTICENTER EUROPEAN STUDY THIS INTERNATIONAL, MULTICENTER, RETROSPECTIVE COHORT STUDY INVOLVED 10 EUROPEAN TERTIARY HOSPITALS ACROSS 4 EUROPEAN COUNTRIES: ATHENS, GREECE (5 CENTERS); MILAN/FOGGIA/VERONA, ITALY; AND ZAGREB, CROATIA AND BUDAPEST, HUNGARY. PFC DRAINAGE WITH DPPS THE PFC WAS DIRECTLY PUNCTURED USING A 10-FR CYSTOTOME (CYSTOTOME TM, COOK MEDICAL, WINSTON SALEM, NC, USA; OR THE CYSTO-GASTRO-SET RU, ENDO-FLEX GMBH, VOERDE, NIEDERRHEIN, NORDRHEIN-WESTFALEN, GERMANY) UNDER ULTRASOUND AND FLUOROSCOPIC GUIDANCE. ONE OR 2 GUIDEWIRES WERE THEN PUSHED INTO THE CAVITY THROUGH THE CYSTOTOME AND PNEUMATIC DILATION OF THE FISTULA WAS PERFORMED USING A 6- OR 8-MM BALLOON (MAXFORCE, BOSTON SCIENTIFIC) AND 1 OR 2 DPPS (3 CM LENGTH, 7 OR 10 FR DIAMETER) DEPLOYED INTO THE PFC. DPPS WERE REMOVED WHEN CLINICAL SUCCESS OF DRAINAGE WAS ACHIEVED. AS PER THE INTENDED USE OF THE CST-10, THE DEVICE IS USED TO ELECTROSURGICALLY PUNCTURE A HOLE IN THE TRANSGASTRIC OR TRANSDUODENAL WALL AND INTO A PANCREATIC PSEUDOCYST, WHEN IT IS VISIBLY BULGING INTO THE GASTROINTESTINAL TRACT. THIS FILE WILL CAPTURE OFF LABEL USE OF THE CST-10 DEVICE FOR THE PUNCTURING OF A WALLED OFF PANCREATIC NECROSIS (WON), POTENTIALLY OCCURRING IN CROATIA. NO ADVERSE EFFECTS REPORTED AS OCCURRING. MEAN AGE 57.2±11.9 YEARS, 71.9% MALE.
CANCELLATION REPORT IS BEING SUBMITTED DUE TO THE COMPLETION OF THE INVESTIGATION ON 14-AUG-2024. INITIAL MDR REPORT GENERATED AND SUBMITTED IN ERROR. CANCELLATION REPORT SCHEDULED FOR SUBMISSION AS THE REPORT HAS BEEN SUBMITTED UNDER PR (B)(4).
Devices
| Seq | Brand | Generic | Product Code | Manufacturer | Model | Lot | UDI-DI |
|---|---|---|---|---|---|---|---|
| 517487 | CYSTOTOME CYSTOENTEROSTOMY NEEDLE KNIFE | KNS UNIT, ELECTROSURGICAL, ENDOSCOPIC | KNS | COOK IRELAND LTD | UNKNOWN |
Patients
| Seq | Age | Sex | Outcome | Treatment |
|---|---|---|---|---|
| 1 | 57 YR | Male |