CONSULTA
Report
- Report Number
- 2647346-2011-00192
- Event Type
- Death
- Date Received
- February 16, 2011
- Date of Event
- February 10, 2010
- Manufacturer
- MEDTRONIC MED REL, INC.
- Product Code
- NIK
- PMA / PMN Number
- P010031/S084
- Removal / Correction Number
- ASKU
- Adverse Event
- Yes
- Report Source
- Manufacturer report
- Reporter Location
- US
- Reporter Occupation
- OTHER
Narratives
THE INFORMATION SUBMITTED REFLECTS ALL RELEVANT DATA RECEIVED. IF ADDITIONAL RELEVANT INFORMATION IS RECEIVED, A SUPPLEMENTAL REPORT WILL BE SUBMITTED. EVALUATION SUMMARY: (B)(4) NO ANOMALIES FOUND. (B)(4) NO ANOMALIES FOUND, ALL CONDUCTORS BLOOD/BODY FLUID (NOT OBSTRUCTED), OUTER INSULATION COSMETIC DEPRESSION. PROXIMAL SEGMENT RETURNED AND ANALYZED. (B)(4) NO ANOMALIES FOUND, ALL INSULATORS BREACHED CUT, APPARENT EXPLANT DAMAGE. PROXIMAL SEGMENT RETURNED AND ANALYZED.
THE INFORMATION SUBMITTED REFLECTS ALL RELEVANT DATA RECEIVED. IF ADDITIONAL RELEVANT INFORMATION IS RECEIVED, A SUPPLEMENTAL REPORT WILL BE SUBMITTED. ANALYSIS OF THE 6947 LEAD IS IN PROCESS; THE RESULTS WILL BE FORWARDED WHEN AVAILABLE. EVALUATION SUMMARY - (B)(4) NO ANOMALIES FOUND. (B)(4) NO ANOMALIES FOUND, ALL CONDUCTORS BLOOD/BODY FLUID (NOT OBSTRUCTED), OUTER INSULATION COSMETIC DEPRESSION. PROXIMAL SEGMENT RETURNED AND ANALYZED.
THE INFORMATION SUBMITTED REFLECTS ALL RELEVANT DATA RECEIVED. IF ADDITIONAL RELEVANT INFORMATION IS RECEIVED, A SUPPLEMENTAL REPORT WILL BE SUBMITTED. ANALYSIS OF THE LEADS IS IN PROCESS; THE RESULTS WILL BE FORWARDED WHEN AVAILABLE. EVALUATION SUMMARY - (B)(4) NO ANOMALIES FOUND.
THE INFORMATION SUBMITTED REFLECTS ALL RELEVANT DATA RECEIVED. IF ADDITIONAL RELEVANT INFORMATION IS RECEIVED, A SUPPLEMENTAL REPORT WILL BE SUBMITTED. ANALYSIS OF THE DEVICE IS IN PROCESS; THE RESULTS WILL BE FORWARDED WHEN AVAILABLE.
ASKU
IT WAS NOTED THE PATIENT DIED 55 DAYS FOLLOWING DEVICE IMPLANT. THE CAUSE OF DEATH IS BEING REQUESTED.
Devices
| Seq | Brand | Generic | Product Code | Manufacturer | Model | Lot | UDI-DI |
|---|---|---|---|---|---|---|---|
| 1 | CONSULTA | IMPLANTABLE PACEMAKER/CARDIO/DEFIB | NIK | MEDTRONIC MED REL, INC. | D224TRK | ASKU |
Patients
| Seq | Age | Sex | Outcome | Treatment |
|---|---|---|---|---|
| 1 | 74 YR | Death | LEAD/CCM IMPLANTABLE PACING LEAD| LEAD/CCM IMPLANTABLE PACING LEAD| MEDTRONIC TISSUE VALVE| LEAD/CCM IMPLANTABLE PACING LEAD| MEDTRONIC TISSUE VALVE| MEDTRONIC TISSUE VALVE| LEAD/CCM IMPLANTABLE PACING LEAD| MEDTRONIC TISSUE VALVE |