SMART MONITOR 2
Report
- Report Number
- 3007056120-2011-00001
- Event Type
- Other
- Date Received
- February 4, 2011
- Date of Event
- December 29, 2010
- Report Date
- January 6, 2011
- Manufacturer
- PHILIPS RESPIRONICS INC
- Product Code
- FLS
- PMA / PMN Number
- K011597
- Adverse Event
- Yes
- Product Problem
- Yes
- Report Source
- Manufacturer report
- Reporter Location
- NE, US
- Reporter Occupation
- OTHER HEALTH CARE PROFESSIONAL
Narratives
THERE WAS NO REPORT OF DEATH OR SERIOUS INJURY, AND THE MFR WAS NOT ABLE TO CONFIRM THE ALLEGATION OF ALARM FAILURE DURING A PT EVENT. THE MONITOR PASSED ALL REQUIRED TESTING AND DETECTED AND ALARMED APPROPRIATELY FOR SIMULATED EVENTS. BASED ON ALL AVAILABLE INFO, THE MFR CONCLUDES THAT THE DEVICE DOES FUNCTION TO SPECIFICATION AND THAT NO FURTHER ACTION IS APPROPRIATE.
A (B)(6) SUPPLIER REPORTED AN INFANT APNEA MONITOR DID NOT ALARM DURING A PT EVENT. IT WAS REPORTED THAT THE INFANT ASPIRATED AND HAD A CYANOTIC EVENT. THE EXACT DATE AND TIME OF THE ALLEGED EVENT IS UNK, HOWEVER; THE DME STATED THAT IT RECEIVED A CALL REGARDING THE EVENT ON (B)(6) 2010. THE (B)(6) REPORTED THAT THE INFANT WAS HOSPITALIZED AND LATER RELEASED WITHOUT PT HARM. THE MFR RECEIVED THE DEVICE FOR EVAL AND DID NOT CONFIRM THE CUSTOMER'S COMPLAINT OF THE UNIT NOT ALARMING. THE APNEA MONITOR WAS VISUALLY EXAMINED AND TESTED BY THE MFR USING A SIMULATOR IN ACCORDANCE WITH THE SMARTMONITOR 2 CHECKOUT PROCEDURE MANUAL (PN (B)(4)). THE APNEA MONITOR DETECTED AND ALARMED APPROPRIATELY FOR SIMULATED EVENTS AND PASSED ALL REQUIRED TESTING. THE SMARTMONITOR 2 WAS SET UP WITH A 16 SECOND DELAY BEFORE RECORDING APNEAS AND A 20 SECOND DELAY BEFORE ANNUNCIATING AND RECORDING ALARM FOR AN APNEA CONDITION. THE SMARTMONITOR 2 WAS PROGRAMMED WITH PARAMETERS THAT WERE APPROPRIATE FOR RECORDING AND ALARMING FOR RESPIRATION AND HEART RATE EVENTS DURING INFANT MONITORING. THE APNEA MONITOR'S MEMORY DATA WAS DOWNLOADED AND ANALYZED BY TRAINED ASSOCIATES. THE DOWNLOADED MEMORY REVEALED THE APNEA MONITOR WAS IN USE FROM (B)(6) 2010. DURING THAT TIME, THERE WERE 56 RECORDED PT EVENTS. ALL PT EVENTS THAT MET THE PARAMETERS FOR AN ALARM CONDITION WERE ASSOCIATED WITH AUDIBLE AND VISUAL ALARMS. THE SMARTMONITOR 2 DEVICE IS NOT INTENDED TO BE USED TO MONITOR PTS FOR CYANOSIS AND HAS NO CAPABILITY TO DO SO. THE SMARTMONITOR 2 PARENTS' GUIDE (PN (B)(4)) STATES IN THE INDICATIONS FOR USE: "THE SMARTMONITOR 2 IS INTENDED FOR USE IN CONTINUOUS MONITORING OF HEART RATE AND RESPIRATION OF INFANT PTS IN A HOME, HOSP OR PORTABLE ENVIRONMENT. ITS PRIMARY FUNCTION IS DETECTION OF CENTRAL APNEA. ITS SECONDARY FUNCTION IS MEASUREMENT OF HEART RATE." THE SMART MONITOR 2 DEVICE IS NOT INTENDED TO PREVENT LOSS OF BREATHING OR HEART ACTIVITY. THE SMARTMONITOR 2 PARENTS' GUIDE (B)(4) FURTHER STATES: "THE SMARTMONITOR 2 IS A MONITORING DEVICE ONLY. IT DOES NOT PREVENT THE LOSS OF BREATHING OR HEART ACTIVITY, NOR WILL IT RESTORE BREATHING OR HEART ACTIVITY. IT WILL NOT PREVENT DEATH. ANYONE USING THE SMARTMONITOR 2 TO MONITOR AN INFANT SHOULD BE TRAINED IN CURRENT INFANT CARDIOPULMONARY RESUSCITATION (CPR), WHICH IS A PROPER WAY TO RESTORE BREATHING AND HEART ACTIVITY."
Devices
| Seq | Brand | Generic | Product Code | Manufacturer | Model | Lot | UDI-DI |
|---|---|---|---|---|---|---|---|
| 1 | SMART MONITOR 2 | APNEA MONITOR | FLS | PHILIPS RESPIRONICS INC | 4003 |
Patients
| Seq | Age | Sex | Outcome | Treatment |
|---|---|---|---|---|
| 1 | Hospitalization |