LAP-BAND ADJUSTABLE GASTRIC BANDING SYSTEM (UNK SIZE)
Report
- Report Number
- 2024601-2011-00099
- Event Type
- Injury
- Date Received
- February 8, 2011
- Date of Event
- October 1, 2010
- Report Date
- January 11, 2011
- Manufacturer
- ALLERGAN
- Product Code
- LTI
- PMA / PMN Number
- P000008
- Adverse Event
- Yes
- Report Source
- Manufacturer report
- Reporter Location
- NY, US
- Reporter Occupation
- NO INFORMATION
Narratives
TAPER UNK. MEDWATCH SENT TO FDA ON: 02/08/2011. THE PRODUCT ASSOCIATED WITH THIS REPORT WILL NOT BE RETURNED. THE CONNECTOR TYPE CANNOT BE IDENTIFIED NOR AN ASSUMPTION MADE AS TO THE TYPE OF CONNECTOR ASSOCIATED WITH THIS COMPLAINT BECAUSE NO SERIAL NUMBER OR IMPLANT DATE WAS GIVEN. EROSION, INFECTION, AND IRRITATION/INFLAMMATION ARE SURGICAL/PHYSIOLOGICAL COMPLICATIONS AND ANALYSIS OF DEVICE GENERALLY DOES NOT ASSIST ALLERGAN IN DETERMINING A PROBABLE CAUSE FOR THESE EVENTS. DEVICE LABELING ADDRESSES THE REPORTED EVENT OF EROSION AS FOLLOWS: "AS WITH OTHER GASTROPLASTY SURGERIES, PARTICULAR CARE MUST BE TAKEN DURING DISSECTION AND DURING IMPLANTATION OF THE DEVICE TO AVOID DAMAGE TO THE GASTROINTESTINAL TRACT. ANY DAMAGE TO THE STOMACH DURING THE PROCEDURE MAY RESULT IN EROSION OF THE DEVICE INTO THE GI TRACT." "OVER-DISSECTION OF THE STOMACH DURING PLACEMENT MAY RESULT IN SLIPPAGE OR EROSION OF THE BAND AND REQUIRE REOPERATION." "THERE IS A RISK OF BAND EROSION INTO STOMACH TISSUE. EROSION OF THE BAND INTO STOMACH TISSUE HAS BEEN ASSOCIATED WITH REVISION SURGERY AFTER THE USE OF GASTRIC-IRRITATING MEDICATIONS, AFTER STOMACH DAMAGE AND AFTER EXTENSIVE DISSECTION OR USE OF ELECTROCAUTERY, AND DURING EARLY EXPERIENCE." DEVICE LABELING ADDRESSES THE REPORTED EVENT OF INFECTION AS FOLLOWS: "INFECTION CAN OCCUR IN THE IMMEDIATE POST-OPERATIVE PERIOD OR YEARS AFTER INSERTION OF THE DEVICE. IN THE PRESENCE OF INFECTION OR CONTAMINATION, REMOVAL OF THE DEVICE IS INDICATED." DEVICE LABELING ADDRESSES THE REPORTED EVENT OF IRRITATION/INFLAMMATION AS FOLLOWS: "CONTRAINDICATION(S): THE LAP-BAND SYSTEM IS CONTRAINDICATED IN: PTS WITH INFLAMMATORY DISEASES OF THE GASTROINTESTINAL TRACT, INCLUDING SEVERE INTRACTABLE ESOPHAGITIS, GASTRIC ULCERATION, DUODENAL ULCERATION, OR SPECIFIC INFLAMMATION SUCH AS CROHN'S DISEASE."
DOCTOR REPORTED EVENTS OF INFECTION, "INFLAMMATORY CHANGES AROUND THE GASTRIC BAND PORT", AND "BAND EROSION", FROM ABSTRACT ENTITLED, "A CASE OF INTRA-GASTRIC BAND MIGRATION (BAND EROSION): A RARE COMPLICATION OF LAPAROSCOPIC ADJUSTABLE GASTRIC BANDING", THE AMERICAN JOURNAL OF GASTROENTEROLOGY (2010) NO. 1029, VOL. 105, SUPP. 1, PAGES S372-373. IT IS ALLERGAN'S APPROACH TO COMPLIANCE TO RESOLVE ALL DOUBT IN FAVOR OF REPORTING.
Devices
| Seq | Brand | Generic | Product Code | Manufacturer | Model | Lot | UDI-DI |
|---|---|---|---|---|---|---|---|
| 1 | LAP-BAND ADJUSTABLE GASTRIC BANDING SYSTEM (UNK SIZE) | LTI | ALLERGAN | NA | NI |
Patients
| Seq | Age | Sex | Outcome | Treatment |
|---|---|---|---|---|
| 1 | 46 YR | Required Intervention |