LAP-BAND ADJUSTABLE GASTRIC BANDING SYSTEM (UNK SIZE)
Report
- Report Number
- 2024601-2011-00094
- Event Type
- Injury
- Date Received
- February 8, 2011
- Date of Event
- January 15, 2010
- Report Date
- January 11, 2011
- Manufacturer
- ALLERGAN
- Product Code
- LTI
- PMA / PMN Number
- P000008
- Adverse Event
- Yes
- Report Source
- Manufacturer report
- Reporter Location
- TX, US
- Reporter Occupation
- NO INFORMATION
Narratives
TAPER UNK. (B)(4). THE PRODUCT ASSOCIATED WITH THIS REPORT WILL NOT BE RETURNED. THE CONNECTOR TYPE CANNOT BE IDENTIFIED NOR AN ASSUMPTION MADE AS TO THE TYPE OF CONNECTOR ASSOCIATED WITH THIS COMPLAINT BECAUSE, NO SERIAL NUMBER OR IMPLANT DATE WAS GIVEN. NECROSIS, OBSTRUCTION, BAND SLIPPAGE, POUCH DILATION, ABDOMINAL PAIN, HERNIA, NAUSEA, AND VOMIT ARE SURGICAL/PHYSIOLOGICAL COMPLICATIONS AND ANALYSIS OF DEVICE GENERALLY DOES NOT ASSIST ALLERGAN IN DETERMINING A PROBABLE CAUSE FOR THESE EVENTS. DEVICE LABELING ADDRESSES THE REPORTED EVENT OF OBSTRUCTION AS FOLLOWS: "OBSTRUCTION OF STOMAS HAS BEEN REPORTED AS BOTH AN EARLY AND A LATE COMPLICATION OF THIS PROCEDURE. THIS CAN BE CAUSED BY EDEMA, FOOD, IMPROPER INITIAL CALIBRATION, BAND SLIPPAGE, POUCH TORSION, OR PT NONCOMPLIANCE REGARDING CHOICE AND CHEWING OF FOOD." "PTS MUST BE CAUTIONED TO CHEW THEIR FOOD THOROUGHLY. PTS WITH DENTURES MUST BE PARTICULARLY CAREFUL TO CUT THEIR FOOD INTO SMALL PIECES. FAILURE TO FOLLOW THESE PRECAUTIONS MAY RESULT IN VOMITING, STOMAL IRRITATION AND EDEMA, POSSIBLY EVEN OBSTRUCTION." "IF THERE IS TOTAL STOMAL OUTLET OBSTRUCTION THAT DOES NOT RESPOND TO BAND DEFLATION, OR IF THERE IS ABDOMINAL PAIN, THEN IMMEDIATE RE-OPERATION TO REMOVE THE BAND IS INDICATED." DEVICE LABELING ADDRESSES THE REPORTED EVENTS OF BAND SLIPPAGE AND POUCH DILATION AS FOLLOWS: "BAND SLIPPAGE AND/OR POUCH DILATATION CAN OCCUR." "OVER-DISSECTION OF THE STOMACH DURING PLACEMENT MAY RESULT IN SLIPPAGE OR EROSION OF THE BAND AND REQUIRE REOPERATION." "GASTROESOPHAGEAL REFLUX, NAUSEA AND/OR VOMITING WITH EARLY OR MINOR SLIPPAGE MAY BE SUCCESSFULLY RESOLVED BY BAND DEFLATION IN SOME CASES. MORE SERIOUS SLIPPAGES MAY REQUIRE BAND REPOSITIONING AND/OR REMOVAL." "FREQUENT, SEVERE VOMITING CAN RESULT IN POUCH DILATATION, STOMACH SLIPPAGE OR ESOPHAGEAL DILATATION." DEVICE LABELING ADDRESSES THE REPORTED EVENT OF ABDOMINAL PAIN AS FOLLOWS: "OTHER ADVERSE EVENTS CONSIDERED RELATED TO THE LAP-BAND SYSTEM THAT OCCURRED IN FEWER THAN 1% OF SUBJECTS INCLUDED: ESOPHAGITIS, GASTRITIS, HIATAL HERNIA, PANCREATITIS, ABDOMINAL PAIN, HERNIA, INCISIONAL INFECTION..." DEVICE LABELING ADDRESSES THE REPORTED EVENTS OF NAUSEA AND VOMIT AS FOLLOWS: "NAUSEA AND VOMITING MAY OCCUR, PARTICULARLY IN THE FIRST FEW DAYS AFTER SURGERY AND WHEN THE PT EATS MORE THAN RECOMMENDED. NAUSEA AND VOMITING MAY ALSO BE SYMPTOMS OF STOMA OBSTRUCTION OR A BAND/STOMACH SLIPPAGE."
DOCTOR REPORTED EVENTS OF "NECROTIZING ULCERATION OF THE FUNDUS", "GASTRIC OUTLET OBSTRUCTION", "SLIPPED LAP BAND", "DILATED PROXIMAL STOMACH WITH HERNIATION", "ABDOMINAL PAIN", NAUSEA, AND VOMITING FROM ABSTRACT ENTITLED, "MIGRATION OF ADJUSTABLE GASTRIC BANDING RESULTING IN SPLENIC INFARCTION AND NECROTIZING GASTRIC ULCERATION: A CASE REPORT", THE AMERICAN JOURNAL OF GASTROENTEROLOGY (2010) NO. 477, VOL. 105, SUPP. 1, PAGE S174. FOLLOW-UP INFORMATION: DOCTOR REPORTED TYPE OF BAND UNK AND DID NOT ABSOLVE THE DEVICE. IT IS ALLERGAN'S APPROACH TO COMPLIANCE TO RESOLVE ALL DOUBT IN FAVOR OF REPORTING.
Devices
| Seq | Brand | Generic | Product Code | Manufacturer | Model | Lot | UDI-DI |
|---|---|---|---|---|---|---|---|
| 1 | LAP-BAND ADJUSTABLE GASTRIC BANDING SYSTEM (UNK SIZE) | LTI | ALLERGAN | NA | NI |
Patients
| Seq | Age | Sex | Outcome | Treatment |
|---|---|---|---|---|
| 1 | 60 YR | Hospitalization| R |