FDA Adverse Event Injury Summary report: N

INTEGRATED APD SET W/CASSETTE3-PRONG

MDR report key: 1980216 · Received February 7, 2011

Report

Report Number
1423500-2011-01566
Event Type
Injury
Date Received
February 7, 2011
Date of Event
January 1, 2011
Report Date
January 17, 2011
Manufacturer
BAXTER HEALTHCARE - MOUNTAIN HOME
Product Code
FKX
PMA / PMN Number
K923065
Adverse Event
Yes
Product Problem
Yes
Report Source
Manufacturer report
Reporter Location
IA, US
Reporter Occupation
NURSE

Narratives

Additional Manufacturer Narrative · 1

(B)(4). UPON FURTHER REVIEW OF COMPLAINT INFORMATION, IT HAS BEEN DETERMINED THAT THIS INCIDENT INVOLVES THE DRUG BAG AND NOT THE DEVICE; THEREFORE, THIS INCIDENT HAS BEEN DETERMINED NOT TO BE A MDR REPORTABLE EVENT.

Additional Manufacturer Narrative · 1

(B)(4). AS THE DATE OF THIS PERITONITIS EPISODE IS UNKNOWN, AND PATIENTS DISCARD SUPPLIES AFTER EACH THERAPY, THE SAMPLE WAS NOT REQUESTED. A FOLLOW-UP REPORT WILL BE SUBMITTED UPON THE RECEIPT OF FURTHER INFORMATION AND COMPLETION OF BAXTER'S INVESTIGATION.

Description of Event or Problem · 1

A NURSE REPORTED TO BAXTER'S GLOBAL PHARMACOVIGILANCE PERITONEAL DIALYSIS (PD) BAGS WITH HOLES (QUANTITY UNKNOWN) AND THE PATIENT HAD BEEN DIAGNOSED WITH PERITONITIS. NURSE WAS UNCERTAIN IF THE PD SOLUTION WAS CAUSALLY RELATED. ON (B)(6) 2011, BAXTER CONTACTED THE DIALYSIS NURSE (PDRN) WHO WAS WITH THE HOME PATIENT(HP) IN THE CLINIC AT THE TIME OF THE CALL. THE HP STATED THAT THE ONSET OF CHILLS AND UPSET STOMACH OCCURRED ON (B)(6) 2011. HE CAME TO THE CLINIC THE NEXT DAY WHERE PERITONEAL EFFLUENT WAS OBTAINED. TREATMENT STARTED IMMEDIATELY WITH ANCEF AND CEFTAZIDIME, EACH 1GM DAILY INTRAPERITONEALLY(IP) FOR 14 DAYS. ON (B)(6) 2011, PD FLUID WAS RECULTURED. TREATMENT WITH ORAL CIPROFLOXIN 200MG TWICE DAILY WAS THEN INITIATED FOR 4 WEEKS. THE HP CONTINUED TREATMENT AT THE TIME OF THIS REPORT AND RECOVERY WAS ONGOING BUT IMPROVED. THE HP AND THE PDRN GAVE CAUSALITY TO THE AMBUFLEX PD2 SOLUTION. THE HP STATED THAT ON THE DAYS PRIOR TO THE ONSET OF HIS SYMPTOMS, HE HAD USED PD SOLUTION FROM 2 INDIVIDUAL BOXES WHICH HAD EXCESSIVE MOISTURE ON THE INSIDE OF THE OUTER PACKAGING, MAKING THE SOLUTION BAG WET. THE HP HAS BEEN ON AUTOMATED PERITONEAL DIALYSIS FOR GREATER THAN 1 YEAR WITH AMBUFLEX (REG CAL) PD2 SOLUTION.

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
1 INTEGRATED APD SET W/CASSETTE3-PRONG SYSTEM, PERITONEAL, AUTOMATIC DELIVERY FKX BAXTER HEALTHCARE - MOUNTAIN HOME

Patients

Seq Age Sex Outcome Treatment
1 47 YR Required Intervention AMBUFLEX (REG CAL) PD2| HOME CHOICE CYCLER