FDA Adverse Event Malfunction Summary report: N

ID NOW COVID-19 2.0 TEST KIT 24T JAPAN

MDR report key: 19761666 · Received July 17, 2024

Report

Report Number
1221359-2024-00502
Event Type
Malfunction
Date Received
July 17, 2024
Date of Event
July 4, 2024
Report Date
July 17, 2024
Manufacturer
ABBOTT DIAGNOSTICS SCARBOROUGH, INC.
Product Code
QWR
UDI-DI
04571226475447
PMA / PMN Number
N/A
Product Problem
Yes
Report Source
Manufacturer report
Reporter Location
JP
Reporter Occupation
OTHER HEALTH CARE PROFESSIONAL
Health Professional
Yes

Narratives

Additional Manufacturer Narrative · 0

D2A: SIMPLE POINT-OF-CARE DEVICE TO DETECT SAR-COV-2 NUCLEIC ACID TARGETS FROM CLINICAL SPECIMENS IN NEAR-PATIENT SETTINGS THIS REPORT IS BEING FILED ON AN INTERNATIONAL PRODUCT, LIST NUMBER 192-000J THAT HAS A SIMILAR PRODUCT DISTRIBUTED IN THE US, LIST NUMBER 192-000. TESTING WAS PERFORMED AT ABBOTT DIAGNOSTICS SCARBOROUGH, INC. ON RETAINED KIT LOT M833188 WITH INTERNAL POSITIVE QUALITY CONTROL SAMPLES AND NEGATIVE QUALITY CONTROL SWABS. ALL TEST RESULTS WERE VALID AND PERFORMED AS EXPECTED. ADDITIONALLY, THE MANUFACTURING RECORDS AND QUALITY CONTROL RELEASE TESTING WAS REVIEWED FOR TEST KIT PART NUMBER 192-000J/ LOT: M833188, TEST BASE PART NUMBER 192-430/ LOT: M833188. THE LOT MET THE REQUIRED RELEASE SPECIFICATIONS. A REVIEW OF THE COMPLAINTS REPORTED AS FALSE POSITIVE PATIENT RESULTS (CONFIRMED AND UNCONFIRMED, CONFLICTING RESULTS) RELATED TO KIT LOT M833188 SHOWED THAT THE COMPLAINT RATE IS (B)(4). ABBOTT DIAGNOSTICS SCARBOROUGH, INC. WAS UNABLE TO DETERMINE THE EXACT ROOT CAUSE OF THE REPORTED ISSUE; HOWEVER, A POSSIBLE ASSIGNABLE ROOT CAUSE IS PATIENT SAMPLE INTERFERENCE.

Description of Event or Problem · 0

THE CUSTOMER REPORTED SIX (6) FALSE POSITIVE RESULTS WITH THE ID NOW COVID-19 ASSAY 2.0 PERFORMED ON MULTIPLE PATIENTS ON VARIOUS DATES. THIS MFR. REPORT ADDRESSES TEST ONE (1) OF SIX (6). THE CUSTOMER REPORTED A FALSE POSITIVE RESULT WITH THE ID NOW COVID-19 ASSAY 2.0 PERFORMED ON (B)(6) 2024 ON A DIRECT TESTED NASOPHARYNGEAL SAMPLE. CONFIRMATION TESTING WAS PERFORMED VIA PCR (PLATFORM: MISUHO SMART GENE) ON AN UNKNOWN DATE WHICH GENERATED A NEGATIVE RESULT. ADDITIONAL TESTING WAS PERFORMED ON AN UNKNOWN DATE VIA MIZUHO ANTIGEN TEST WHICH GENERATED A NEGATIVE RESULT. THE CUSTOMER CONFIRMED THERE WAS NO PATIENT HARM DUE TO THE TEST RESULTS. ADDITIONALLY, THE CUSTOMER CONFIRMED THERE WAS NO DELAY OR IMPACT IN THE PATIENT'S TREATMENT.

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
355476 ID NOW COVID-19 2.0 TEST KIT 24T JAPAN SIMPLE POINT-OF-CARE DEVICE TO DETECT SAR-COV-2 NUCLEIC ACID TARGETS QWR ABBOTT DIAGNOSTICS SCARBOROUGH, INC. M833188 04571226475447

Patients

Seq Age Sex Outcome Treatment
1 NA Unknown