ACRYSOF IQ PANOPTIX TORIC TRIFOCAL IOL
Report
- Report Number
- 1119421-2024-01256
- Event Type
- Malfunction
- Date Received
- July 4, 2024
- Date of Event
- May 31, 2024
- Report Date
- September 19, 2024
- Manufacturer
- ALCON RESEARCH, LLC - HUNTINGTON
- Product Code
- MFK
- UDI-DI
- 00380652389389
- PMA / PMN Number
- P040020
- Removal / Correction Number
- NA
- Product Problem
- Yes
- Report Source
- Manufacturer report
- Reporter Location
- UK
- Reporter Occupation
- 003
Narratives
INVESTIGATION INCLUDING ROOT CAUSE ANALYSIS IS IN PROGRESS. A SUPPLEMENTAL MDR WILL BE FILED AS NECESSARY IN ACCORDANCE WITH 21 CFR 803.56 WHEN ADDITIONAL REPORTABLE INFORMATION BECOMES AVAILABLE. THE MANUFACTURER INTERNAL REFERENCE NUMBER IS: (B)(4).
THIS PRODUCT IS NOT APPROVED OR INTRODUCED INTO COMMERCIAL DISTRIBUTION IN THE UNITED STATES. HOWEVER, THIS MEDWATCH IS BEING FILED BASED ON A SIMILAR PRODUCT (TFNT30-60) THAT IS SOLD IN THE UNITED STATES UNDER (PMA/510(K) # (P040020). ADDITIONAL INFORMATION HAS BEEN PROVIDED IN H.3., H.6., AND H.11.THE PRODUCT WAS NOT RETURNED. PRODUCT HISTORY RECORDS WERE REVIEWED AND THE DOCUMENTATION INDICATED THE PRODUCT MET RELEASE CRITERIA. ASSOCIATED PRODUCTS WERE NOT PROVIDED. IT IS UNKNOWN IF QUALIFIED PRODUCTS WERE USED. THE PRODUCT INVESTIGATION COULD NOT IDENTIFY A ROOT CAUSE FOR THE REPORTED COMPLAINT. THE PRODUCT HAS NOT BEEN RECEIVED TO EVALUATE. ASSOCIATED PRODUCTS WERE NOT PROVIDED. IT IS UNKNOWN IF QUALIFIED PRODUCTS WERE USED. THE IFU INSTRUCTS: COMPANY FOLDABLE IOLS ARE QUALIFIED FOR USE WITH A COMPANY QUALIFIED DELIVERY SYSTEM (HANDPIECE AND CARTRIDGE) AND OPHTHALMIC VISCOSURGICAL DEVICE (OVD) COMBINATION. THE IFU INSTRUCTS THAT A COMPANY QUALIFIED DELIVERY SYSTEM AND VISCOELASTIC COMBINATION SHOULD BE USED. THE USE OF AN UNQUALIFIED COMBINATION MAY CAUSE DAMAGE TO THE LENS AND POTENTIAL COMPLICATIONS DURING THE IMPLANTATION PROCESS. THE IFU INSTRUCTS: USING HOLDING FORCEPS, GRASP THE LENS BY THE OPTIC EDGE AND GENTLY PLACE THE LENS ANTERIOR SIDE UP INTO THE BACK OF THE OVD-FILLED CARTRIDGE. THE LENS SHOULD BE INSERTED UNTIL THE OPTIC IS A LITTLE MORE THAN HALF-WAY INSIDE THE CARTRIDGE. USE THE HOLDING FORCEPS TO GENTLY PUSH DOWN ON THE LENS, VERIFYING THAT THE LENS IS ON THE BOTTOM SURFACE OF THE CARTRIDGE. USING HOLDING FORCEPS, TAKE THE TRAILING HAPTIC, AND GENTLY FOLD THE HAPTIC ONTO THE ANTERIOR SIDE OF THE OPTIC. SLOWLY GRIP OR PUSH THE OPTIC EDGE TO POSITION THE LENS AS FAR INTO THE CARTRIDGE AS THE FORCEPS WILL PERMIT, WHILE ENSURING THE LENS REMAINS ON THE BOTTOM SURFACE OF THE CARTRIDGE AND THE TRAILING HAPTIC REMAINS ON THE OPTIC. FAILURE TO FOLLOW THESE STEPS MAY CAUSE THE LENS TO ADVANCE INCORRECTLY CAUSING DELIVERY ISSUES AND/OR DAMAGE. DUE DILIGENCE HAS BEEN PERFORMED IN AN ATTEMPT TO OBTAIN FURTHER INFORMATION ON THIS EVENT. THE REPORTER HAS NOT RESPONDED TO REQUESTS FOR FOLLOW-UP INFORMATION. FILE WILL BE REOPENED IF NEW INFORMATION OR THE SAMPLE IS RECEIVED. THE MANUFACTURER INTERNAL REFERENCE NUMBER IS: (B)(4).
A NON HEALTH CARE PROFESSIONAL REPORTED THAT DURING SURGERY, THEY NOTICED THAT A SCRATCH ON THE LENS, REPLACED USING THE BACK UP LENS. ADDITIONAL INFORMATION HAS BEEN REQUESTED.
Devices
| Seq | Brand | Generic | Product Code | Manufacturer | Model | Lot | UDI-DI |
|---|---|---|---|---|---|---|---|
| 1182473 | ACRYSOF IQ PANOPTIX TORIC TRIFOCAL IOL | LENS, MULTIFOCAL INTRAOCULAR | MFK | ALCON RESEARCH, LLC - HUNTINGTON | TFNT20 | 15636818 | 00380652389389 |
Patients
| Seq | Age | Sex | Outcome | Treatment |
|---|---|---|---|---|
| 1 | NA | Unknown | PACKER CHANG IOL CUTTER |