FDA Adverse Event Malfunction Summary report: N

HAMILTON-T1

MDR report key: 19640337 · Received June 29, 2024

Report

Report Number
3001421318-2024-01557
Event Type
Malfunction
Date Received
June 29, 2024
Date of Event
May 23, 2024
Report Date
November 3, 2025
Manufacturer
HAMILTON MEDICAL AG
Product Code
CBK
UDI-DI
07630002801850
PMA / PMN Number
K181216
Product Problem
Yes
Report Source
Manufacturer report
Reporter Location
NV, US
Reporter Occupation
003

Narratives

Additional Manufacturer Narrative · 0

HAMILTON MEDICAL AG COMPLAINT NUMBER: (B)(4). FOLLOW-UP 1 - CORRECTED INFORMATION: **UDI RELATED DATA QUALITY UPDATES ONLY** FIELD D4 WAS UPDATED WITH FULL UDI INFORMATION. UPDATED FIELDS: B4, D1, D3, D4, G6, H2, H4, H11.

Description of Event or Problem · 0

THE FOLLOWING HAS BEEN REPORTED TO HAMILTON MEDICAL AG ON 28 MAY 2024 IT WAS REPORTED BY HAMILTON MEDICAL INC, THAT ON 23 MAY 2024, A HAMILTON T1 VENTILATOR (SN (B)(6)) FAILED TO TURN-ON. THE DISPLAY OR THE DEVICE REMAINS DARK AND IT SHOWS NO VISUAL OR AUDIBLE ALARM. ACCORDING TO THE PRELIMINARY INVESTIGATION PERFORMED, POTENTIAL ROOT CAUSE ASSOCIATED TO THE REPORTED ISSUE ARE AS FOLLOW: -DEFECTIVE ESM. -DEFECTIVE DRIVER BOARD. -DEFECTIVE CONTROL BOARD. -DEFECTIVE FRONT PANEL BOARD. THE FOLLOWING CORRECTION CAN BE CONSIDERED ACCORDINGLY: - ENSURE CABLE CONNECTIONS BETWEEN DRIVER BOARD AND CONTROL BOARD ARE PROPERLY CONNECTED. - ENSURE FFC BETWEEN CONTROL BOARD AND FRONT PANEL BOARD IS PROPERLY CONNECTED AND IN GOOD CONDITION. - CHECK VOLTAGES AT VOLTAGE TEST POINT P5 ON CONTROL BOARD. - REPLACE DEFECTIVE COMPONENT. ACCORDING TO THE AVAILABLE INFORMATION, THERE IS NO INDICATION THAT THE COMPLAINT LEAD TO DEATH, INJURY OR SERIOUS DETERIORATION OF THE HEALTH OF THE PATIENT, USER OR THIRD-PARTY.

Description of Event or Problem · 0

THE FOLLOWING HAS BEEN REPORTED TO HAMILTON MEDICAL AG ON 28 MAY 2024. IT WAS REPORTED, BY HAMILTON MEDICAL INC. THAT ON 23 MAY 2024, A HAMILTON T1 VENTILATOR (SN (B)(6)) FAILED TO TURN-ON. THE DISPLAY OR THE DEVICE REMAINS DARK. AND IT SHOWS NO VISUAL OR AUDIBLE ALARM. ACCORDING TO THE PRELIMINARY INVESTIGATION PERFORMED, POTENTIAL ROOT CAUSE ASSOCIATED TO THE REPORTED ISSUE ARE AS FOLLOW: DEFECTIVE ESM, DEFECTIVE DRIVER BOARD, DEFECTIVE CONTROL BOARD, DEFECTIVE FRONT PANEL BOARD THE FOLLOWING CORRECTION CAN BE CONSIDERED ACCORDINGLY: ENSURE CABLE CONNECTIONS BETWEEN DRIVER BOARD AND CONTROL BOARD ARE PROPERLY CONNECTED. ENSURE FFC BETWEEN CONTROL BOARD AND FRONT PANEL BOARD IS PROPERLY CONNECTED AND IN GOOD CONDITION. CHECK VOLTAGES AT VOLTAGE TEST POINT P5 ON CONTROL BOARD. REPLACE DEFECTIVE COMPONENT. ACCORDING TO THE AVAILABLE INFORMATION, THERE IS NO INDICATION, THAT THE COMPLAINT LEAD TO DEATH, INJURY OR SERIOUS DETERIORATION OF THE HEALTH OF THE PATIENT, USER OR THIRD-PARTY.

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
851592 HAMILTON-T1 HAMILTON-T1 CBK HAMILTON MEDICAL AG 161006 07630002801850

Patients

Seq Age Sex Outcome Treatment
1 NA Unknown