AUTOSOFT 30
Report
- Report Number
- 3003442380-2024-08999
- Event Type
- Injury
- Date Received
- June 19, 2024
- Date of Event
- May 6, 2024
- Report Date
- August 14, 2025
- Manufacturer
- UNOMEDICAL A/S
- Product Code
- FPA
- UDI-DI
- 05705244018365
- PMA / PMN Number
- K061374
- Adverse Event
- Yes
- Product Problem
- Yes
- Report Source
- Manufacturer report
- Reporter Location
- CA, US
- Reporter Occupation
- 003
Narratives
INITIAL AND FINAL MDR 1890609 - DEVICE 3 OF 4.
SUPPLEMENTAL REPORT 01 - MDR (B)(4): CORRECTION: THIS MDR IS BEING SUBMITTED TO CORRECT THE SUBMITTED EXPIRATION DATE UNDER D4 AND MANUFACTURING DATE UNDER H4. ADDITIONAL INFORMATION - THIS MDR IS BEING SUBMITTED TO INCLUDE THE BELOW: H6: INVESTIGATION RESULTS UNDER TYPE OF INVESTIGATION, INVESTIGATION FINDINGS, INVESTIGATION CONCLUSIONS H11: INVESTIGATION SUMMARY THE INFORMATION IN THIS COMPLAINT (B)(6) HAS BEEN EVALUATED. THE BATCH 6004579 IN QUESTION WAS MANUFACTURED AT THE REYNOSA SITE. THE INVESTIGATION PROCESS OF THE COMPLAINT WAS CARRIED OUT IN ACCORDANCE WITH WORK INSTRUCTION (WI) GUIDANCE FOR VISUAL TESTING FOR COMPLAINTS AREA VERSION 03 FOR THE CODE ADHESIVE PATCH DOES NOT ADHERE TO THE SKIN AT POINT OF APPLICATION (I.E. NOT STICKY, NO ATTACHMENT, OR A FEW MINUTES OF ATTACHMENT). COMPLAINT INVESTIGATIONS. PHOTO/SAMPLE WAS NOT PROVIDED. IN ORDER TO TEST THE PRODUCT, THE REFERENCE SAMPLES FROM THE LOT HAVE BEEN REQUESTED. TEST RESULTS: VISUAL TEST ACCORDING TO WI VERSION 03 ON REFERENCE SAMPLES, 10 SAMPLES OUT 10 SAMPLES PASSED THE TEST. DEVICE HISTORY RECORD (DHR) REVIEW: PACKING LOT 6004579 WAS MANUFACTURED ACCORDING TO THE WI VERSION 26 IN THE LINE 01, ON 02/DEC/2023, WITH A TOTAL OF (B)(4) UNITS. REVIEW OF THE DHR SHOWED THAT ALL RELEVANT TESTS REQUIRED DURING THE RELATED PROCESSES HAD BEEN FULFILLED AND MET THE REQUIREMENTS. NO DEVIATION WERE IDENTIFIED RELATED TO THE MALFUNCTION REPORTED, NO MAINTENANCE EVENTS WERE RECORDED. TRENDING: A QUERY WAS RUN IN DATABASE ON 11/AUG/2025 AGAINST MALFUNCTION CODE ADHESIVE PATCH DOES NOT ADHERE TO THE SKIN AT POINT OF APPLICATION (I.E. NOT STICKY, NO ATTACHMENT, OR A FEW MINUTES OF ATTACHMENT) AND LOT 6004579 AND OTHER ONE COMPLAINT HAS BEEN REGISTERED IN DATABASE FOR THE SAME LOT 6004579 AND MALFUNCTION CODE. CONCLUSION SUMMARY OF THE RELATED EVENT: AS A RESULT OF THE FOLLOWING: NO DEFECT ON TESTS FOR REFERENCE SAMPLES, NO HARM, NO NON-CONFORMANCE RAISED DURING PRODUCTION, OTHER ONE COMPLAINT RECEIVED ON THE LOT IN QUESTION AND MALFUNCTION CODE. NO FURTHER ACTIONS ARE REQUIRED. THIS COMPLAINT WILL NOT REQUIRE FURTHER ROOT CAUSE INVESTIGATION NOR CORRECTIVE AND PREVENTIVE ACTION PLAN. THEREFORE, THIS ISSUE WILL BE MONITORED THROUGH THE POST MARKET SURVEILLANCE ACTIVITIES.
UNOMEDICAL REFERENCE NUMBER (B)(4). EVENT OCCURRED IN THE UNITED STATES. IT WAS REPORTED THAT PATIENT FACED 4 INFUSIONS SET FALL OFF EVENTS ON (B)(6)2024 . INFUSION SET FELL OFF DURING PHYSICAL ACTIVITY/SWEATING, SWIMMING, OR BATHING. AREA OF INSERTION WAS CLEANED, AIR DRIED AND FREE FROM HAIR. PATIENT WAS ASSISTED BY BULTER MEMORIAL HOSPITALS. PATIENT WAS EXPERIENCED WITH HIGH LEVEL OF KETONES AND IT LED TO BE LIFE THREATENING. NO FURTHER INFORMATION AVAILABLE.
TO DATE NO ADDITIONAL PATIENT OR EVENT DETAILS HAVE BEEN RECEIVED.
Devices
| Seq | Brand | Generic | Product Code | Manufacturer | Model | Lot | UDI-DI |
|---|---|---|---|---|---|---|---|
| 1577351 | AUTOSOFT 30 | UNO INSET 30 60/13 GREY TCAP 10PK INT | FPA | UNOMEDICAL A/S | 1002825 | 6004579 | 05705244018365 |
Patients
| Seq | Age | Sex | Outcome | Treatment |
|---|---|---|---|---|
| 1 | 35 YR | Female | Hospitalization| R| L |