BD CONVENTIONAL NEEDLES BLT FILL NC TW SHLD
Report
- Report Number
- 3002682307-2024-00137
- Event Type
- Malfunction
- Date Received
- June 17, 2024
- Date of Event
- May 27, 2024
- Report Date
- August 19, 2024
- Manufacturer
- BECTON DICKINSON, S.A.
- Product Code
- FMI
- UDI-DI
- 00382903031290
- PMA / PMN Number
- UNK
- Product Problem
- Yes
- Report Source
- Manufacturer report
- Reporter Location
- NL
- Reporter Occupation
- 003
Narratives
H.3. A FOLLOW UP MDR WILL BE SUBMITTED IF ADDITIONAL INFORMATION, A DEVICE EVALUATION, OR A DEVICE HISTORY REVIEW IS COMPLETED.
A DEVICE HISTORY RECORD REVIEW WAS COMPLETED FOR PROVIDED MATERIAL NUMBER 303129 AND LOT NUMBER 240109. THE REVIEW DID NOT REVEAL ANY DETECTED ABNORMALITIES DURING THE PRODUCTION PROCESS THAT COULD HAVE CONTRIBUTED TO THE REPORTED DEFECT AND ALL QUALITY TESTS WERE FOUND TO BE WITHIN SPECIFICATION. TO AID IN THE INVESTIGATION OF THIS ISSUE, THREE (3) PICTURE SAMPLES WERE RECEIVED FOR EVALUATION BY OUR QUALITY TEAM. THROUGH EXAMINATION OF THE PICTURES, A HAIR WAS IDENTIFIED WITHIN THE NEEDLE¿S BLISTER PACKAGING. IT HAS BEEN DETERMINED THAT THIS INCIDENT RESULTED FROM A TEMPORARY FAILURE IN GOOD MANUFACTURING PRACTICES. THIS IS A VERY UNUSUAL INCIDENT AS BD MAINTAINS STRINGENT MANUFACTURING PROCESSES AND ENVIRONMENTAL CONTROLS TO KEEP FOREIGN MATTER TO EXTREMELY LOW LEVELS. THE ENTIRE ASSEMBLY AND PACKAGING PROCESS TAKES PLACE IN AN ENVIRONMENTAL CONTROLLED ROOM WHERE STRICT MEASURES ARE IN PLACE, INCLUDING CONTINUOUSLY FILTERED AIR, HIGHER PAIR PRESSURE IN THE CONTROLLED AREA THAN THE SURROUNDINGS, DOUBLE DOOR ACCESS, RESTRICTED ACCESS TO PERSONNEL, THE USE OF SPECIAL MANDATORY CLOTHING, AND ROUTINE TRAINING COURSES ON GOOD MANUFACTURING PRACTICES. BASED ON THE PREVENTIVE MEASURES IN PLACE, WE BELIEVE THIS WAS AN ISOLATED INCIDENT WITH AN UNLIKELY CHANCE OF RECURRENCE. THE MANUFACTURING PERSONNEL WERE ALERTED OF YOUR EXPERIENCE FOR FURTHER AWARENESS ON THE PRODUCTION FLOOR. OUR QUALITY TEAM WILL CONTINUE TO CLOSELY MONITOR THE MANUFACTURING PROCESS FOR SIGNS OF THIS POTENTIAL DEFECT AND ANY EMERGING TRENDS.
IT WAS REPORTED THAT BD CONVENTIONAL NEEDLES BLT FILL NC TW SHLD HAIR FOUND IN THE PACKAGE THE FOLLOWING INFORMATION WAS PROVIDED BY THE INITIAL REPORTER TRANSLATED FROM DUTCH TO ENGLISH: I HEREBY REPORT A COMPLAINT, A HAIR WAS FOUND IN A PACKAGE. THE NEEDLE IS STILL PRESENT.
NO ADDITIONAL INFORMATION.
Devices
| Seq | Brand | Generic | Product Code | Manufacturer | Model | Lot | UDI-DI |
|---|---|---|---|---|---|---|---|
| 2322726 | BD CONVENTIONAL NEEDLES BLT FILL NC TW SHLD | NEEDLES, HYPODERMIC | FMI | BECTON DICKINSON, S.A. | 240109 | 00382903031290 |
Patients
| Seq | Age | Sex | Outcome | Treatment |
|---|---|---|---|---|
| 1 | NA | Unknown |