FDA Adverse Event Malfunction Summary report: N

MINICAP

MDR report key: 19521790 · Received June 12, 2024

Report

Report Number
1416980-2024-02870
Event Type
Malfunction
Date Received
June 12, 2024
Date of Event
May 17, 2024
Report Date
July 18, 2024
Manufacturer
BAXTER INTERNATIONAL INC.
Product Code
KDJ
UDI-DI
00085412007731
PMA / PMN Number
K152675
Product Problem
Yes
Report Source
Manufacturer report
Reporter Location
CA, US
Reporter Occupation
NURSE
Health Professional
Yes

Narratives

Additional Manufacturer Narrative · 0

D1: BRAND NAME: REPLACE MINICAP TRANSFER SET WITH MINICAP. D3: DEVICE MANUFACTURER NAME: REPLACE BAXTER HEALTHCARE CORPORATION WITH BAXTER INTERNATIONAL INC. D4: UNIQUE IDENTIFIER (UDI) #: REPLACE (B)(4) WITH (B)(4). G4: COMBINATION PRODUCT: ADD NO (PREVIOUSLY BLANK). H11: THE DEVICE WAS RECEIVED FOR EVALUATION. A VISUAL INSPECTION WITH THE NAKED EYE NOTED A SEPARATION BETWEEN THE DARK BLUE FEMALE CONNECTOR AND THE LIGHT BLUE MAIN BODY OF THE TWIST CLAMP. FUNCTIONAL TESTING INCLUDING LEAK, CLEAR PASSAGE, AND CLAMP FUNCTION TESTING WERE PERFORMED WITH NO ISSUES NOTED. THE REPORTED CONDITION WAS VERIFIED. THE CAUSE OF THE CONDITION WAS RELATED TO INADEQUATE SOLVENT APPLICATION BETWEEN THE FEMALE CONNECTOR, INSERT CHIP, AND MAIN BODY DURING THE MANUFACTURING PROCESS. A BATCH REVIEW WAS CONDUCTED AND THERE WERE NO DEVIATIONS FOUND RELATED TO THIS CONDITION DURING THE MANUFACTURE OF THIS LOT. SHOULD ADDITIONAL RELEVANT INFORMATION BECOME AVAILABLE, A SUPPLEMENTAL REPORT WILL BE SUBMITTED.

Additional Manufacturer Narrative · 0

E1: INITIAL REPORTER ADDRESS: (B)(6). THE DEVICE HAS BEEN RECEIVED AND THE EVALUATION IS IN PROGRESS. SHOULD ADDITIONAL RELEVANT INFORMATION BECOME AVAILABLE, A SUPPLEMENTAL REPORT WILL BE SUBMITTED.

Description of Event or Problem · 0

IT WAS REPORTED THERE WAS A SEPARATION BETWEEN THE FEMALE CONNECTOR (DARK BLUE) AND THE MAIN BODY (LIGHT BLUE) OF THE TWIST CLAMP ON A MINICAP TRANSFER SET. THIS WAS DESCRIBED AS ¿THE DARK BLUE UNSCREWED FROM THE LIGHT BLUE." THIS WAS OBSERVED WHILE DISCONNECTING FROM PERITONEAL DIALYSIS THERAPY. THE TRANSFER SET WAS REPLACED TO RESOLVE THE ISSUE. THERE WAS NO REPORT OF PATIENT INJURY OR MEDICAL INTERVENTION ASSOCIATED WITH THIS EVENT. NO ADDITIONAL INFORMATION IS AVAILABLE.

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
153060 MINICAP SET, ADMINISTRATION, FOR PERITONEAL DIALYSIS, DISPOSABLE KDJ BAXTER INTERNATIONAL INC. NA H24A03061 00085412007731

Patients

Seq Age Sex Outcome Treatment
1 NA Unknown