FDA Adverse Event Injury Summary report: N

DEPUY PINNACLE SECTOR II ACETABULAR CUP SIZE 54/MM

MDR report key: 1950630 · Received December 29, 2010

Report

Report Number
MW5018767
Event Type
Injury
Date Received
December 29, 2010
Date of Event
October 3, 2008
Report Date
December 29, 2010
Manufacturer
JOHNSON & JOHNSON
Product Code
LPH
Adverse Event
Yes
Product Problem
Yes
Report Source
Voluntary report
Reporter Location
AL, US
Reporter Occupation
PATIENT

Narratives

Description of Event or Problem · 1

HAD A DEPUY PINNACLE HIP IMPLANT IN (B)(6) 2005. AFTER REHAB FOLLOWING THE SURGERY, THE IMPLANT CAUSED MILD TO MODERATE PAIN OVER THE NEXT 2.5 YEARS. IN (B)(6) OF 2008, I AWOKE ONE MORNING WITH ACUTE PAIN IN MY RIGHT HIP AND THIGH. I WENT TO THE ER AND WAS X-RAYED, CT SCANNED, BOTH SHOWED NO ABNORMALITIES, GIVEN PAIN MEDICATION AND SENT HOME. THE PAIN SUBSIDED AFTER 2-3 DAYS. APPROXIMATELY 6 MONTHS LATER, (B)(6), 2008, THE ACUTE PAIN CAME BACK. WENT TO ER MRI SHOWED MILD INFLAMMATION, GIVEN PAIN MEDICATION AND SENT HOME. THIS TIME, THE PAIN DID NOT GO AWAY AND I WAS HOSPITALIZED IN (B)(6), 4 DAYS LATER. IT WAS DETERMINED THAT THE DEPUY PINNACLE HIP THAT HAD BEEN PUT IN WAS INFECTED. THREE TO FOUR SURGERIES WERE PERFORMED IN AN EFFORT TO SAVE THE HIP. IT WAS DETERMINED THAT THE HIP COULD NOT BE SAVED. I WENT TO A SPECIALIST IN (B)(6), THAT REMOVED THE DEPUY PROSTHESIS. SIX WEEKS WITHOUT A HIP AND ON IV ANTIBIOTIC THERAPY FOLLOWED. AFTER SIX WEEKS, A NEW PROSTHESIS WAS IMPLANTED.

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
1 DEPUY PINNACLE SECTOR II ACETABULAR CUP SIZE 54/MM DEPUY PINNACLE HIP PROSTHESIS LPH JOHNSON & JOHNSON

Patients

Seq Age Sex Outcome Treatment
1 53 YR Hospitalization| R| S