FDA Adverse Event Malfunction Summary report: N

INSTINCT PLUS ENDOSCOPIC CLIPPING DEVICE

MDR report key: 19498327 · Received June 10, 2024

Report

Report Number
1037905-2024-00318
Event Type
Malfunction
Date Received
June 10, 2024
Date of Event
May 16, 2024
Report Date
July 18, 2024
Manufacturer
WILSON-COOK MEDICAL INC
Product Code
PKL
UDI-DI
00827002580107
Product Problem
Yes
Report Source
Manufacturer report
Reporter Occupation
NURSE
Health Professional
Yes

Narratives

Additional Manufacturer Narrative · 0

510(K): K212323 INVESTIGATION EVALUATION: A PRODUCT EVALUATION WAS NOT PERFORMED IN RESPONSE TO THIS REPORT BECAUSE THE PRODUCT SAID TO BE INVOLVED WAS NOT PROVIDED TO COOK FOR EVALUATION. THE REPORT COULD NOT BE CONFIRMED. THE DEVICE HISTORY RECORD FOR THE LOT NUMBER SAID TO BE INVOLVED WAS REVIEWED. A DISCREPANCY OR ANOMALY WAS NOT OBSERVED WITH THE PRODUCT THAT WAS RELEASED FOR DISTRIBUTION. INVESTIGATION CONCLUSION: THE ADDITIONAL INFORMATION INDICATED THE USER HELD THE HANDLE SPOOL DURING ADVANCEMENT THROUGH THE ACCESSORY CHANNEL. THIS IS THE MOST LIKELY CAUSE OF THIS REPORT. THE INSTRUCTIONS FOR USE STATES: "WITH CLIP CLOSED AND WITHOUT HOLDING HANDLE SPOOL, ADVANCE DEVICE IN SMALL INCREMENTS INTO ACCESSORY CHANNEL OF GASTROSCOPE OR COLONOSCOPE. CAUTION: HOLDING HANDLE SPOOL DURING CLIP ADVANCEMENT MAY PREMATURELY DEPLOY CLIP." FAILURE TO FOLLOW THE INSTRUCTIONS ABOVE CAN RESULT IN DAMAGE TO THE DEVICE WHICH MAY LEAD TO PREMATURE CLIP DEPLOYMENT. HOWEVER, EVEN IF THE CLIP IS NOT DEPLOYED, DAMAGE CAN OCCUR TO INTERNAL DEVICE COMPONENTS SUCH AS THE DRIVER LEGS. ONCE THIS DAMAGE OCCURS, THE CLIP IS IN A PARTIALLY DEPLOYED STATE AND MAY NOT BE ABLE TO BE OPENED/REOPENED. PRIOR TO DISTRIBUTION, ALL INSTINCT PLUS ENDOSCOPIC CLIPPING DEVICE ARE SUBJECTED TO A VISUAL INSPECTION AND FUNCTIONAL TESTING TO ENSURE DEVICE INTEGRITY. A REVIEW OF THE DEVICE HISTORY RECORD CONFIRMED THAT THE LOT SAID TO BE INVOLVED MET ALL MANUFACTURING REQUIREMENTS PRIOR TO SHIPMENT. CORRECTIVE ACTION: A REVIEW OF THE COMPLAINT HISTORY WAS CONDUCTED. THE LIKELIHOOD OF OCCURRENCE IS CONSIDERED RARE. CORRECTIVE ACTION IS NOT WARRANTED AT THIS TIME BASED ON THE QUALITY ENGINEERING RISK ASSESSMENT. QUALITY ASSURANCE WILL CONTINUE TO MONITOR FOR COMPLAINT TRENDS AND REASSESS THE RISK ASSESSMENT RESULTS AS POST MARKET FEEDBACK CONTINUES TO BECOME AVAILABLE. ADDITIONAL COMMENTS: BASED ON THE INFORMATION PROVIDED THAT THE USER HELD THE HANDLE SPOOL DURING ADVANCEMENT THROUGH THE ACCESSORY CHANNEL, A COOK REPRESENTATIVE HAS PROVIDED TRAINING TO THE MEDICAL FACILITY INVOLVED IN AN EFFORT TO PROMOTE FURTHER EDUCATION AND UNDERSTANDING RELATED TO APPROPRIATE USAGE OF THIS PRODUCT.

Additional Manufacturer Narrative · 0

510(K): K212323. INVESTIGATION EVALUATION: THE PRODUCT SAID TO BE INVOLVED WAS RETURNED IN A RED BIOHAZARD BAG WITH AN OPEN POUCH FROM THE LOT NUMBER PROVIDED IN THE REPORT. THE LABEL MATCHES THE PRODUCT RETURNED. OUR LABORATORY EVALUATION OF THE PRODUCT SAID TO BE INVOLVED CONFIRMED THE REPORT. A VISUAL EXAMINATION CONFIRMED THE CLIP HOUSING HAS SEPARATED FROM THE COIL CATHETER BUT REMAINS ATTACHED TO THE END OF THE DRIVE WIRE, IN A CLOSED POSITION. THE CLIP COULD NOT BE REOPENED. THE DEVICE WAS VIEWED UNDER MAGNIFICATION AND A PRODUCT DISCREPANCY OR ANOMALY THAT COULD HAVE CONTRIBUTED TO THIS REPORTED OCCURRENCE WAS NOT OBSERVED. THE DEVICE HISTORY RECORD FOR THE LOT NUMBER SAID TO BE INVOLVED WAS REVIEWED. A DISCREPANCY OR ANOMALY WAS NOT OBSERVED WITH THE PRODUCT THAT WAS RELEASED FOR DISTRIBUTION. INVESTIGATION CONCLUSION: OUR LABORATORY EVALUATION OF THE RETURNED DEVICE CONFIRMED THE REPORT. THE ADDITIONAL INFORMATION INDICATED THE USER HELD THE HANDLE SPOOL DURING ADVANCEMENT THROUGH THE ACCESSORY CHANNEL. THIS IS THE MOST LIKELY CAUSE OF THIS REPORT. THE INSTRUCTIONS FOR USE STATES: "WITH CLIP CLOSED AND WITHOUT HOLDING HANDLE SPOOL, ADVANCE DEVICE IN SMALL INCREMENTS INTO ACCESSORY CHANNEL OF GASTROSCOPE OR COLONOSCOPE. CAUTION: HOLDING HANDLE SPOOL DURING CLIP ADVANCEMENT MAY PREMATURELY DEPLOY CLIP." FAILURE TO FOLLOW THE INSTRUCTIONS ABOVE CAN RESULT IN DAMAGE TO THE DEVICE WHICH MAY LEAD TO PREMATURE CLIP DEPLOYMENT. HOWEVER, EVEN IF THE CLIP IS NOT DEPLOYED, DAMAGE CAN OCCUR TO INTERNAL DEVICE COMPONENTS SUCH AS THE DRIVER LEGS. ONCE THIS DAMAGE OCCURS, THE CLIP IS IN A PARTIALLY DEPLOYED STATE AND MAY NOT BE ABLE TO BE OPENED/REOPENED. PRIOR TO DISTRIBUTION, ALL INSTINCT PLUS ENDOSCOPIC CLIPPING DEVICE ARE SUBJECTED TO A VISUAL INSPECTION AND FUNCTIONAL TESTING TO ENSURE DEVICE INTEGRITY. A REVIEW OF THE DEVICE HISTORY RECORD CONFIRMED THAT THE LOT SAID TO BE INVOLVED MET ALL MANUFACTURING REQUIREMENTS PRIOR TO SHIPMENT. CORRECTIVE ACTION: A REVIEW OF THE COMPLAINT HISTORY WAS CONDUCTED. THE LIKELIHOOD OF OCCURRENCE IS CONSIDERED RARE. CORRECTIVE ACTION IS NOT WARRANTED AT THIS TIME BASED ON THE QUALITY ENGINEERING RISK ASSESSMENT. QUALITY ASSURANCE WILL CONTINUE TO MONITOR FOR COMPLAINT TRENDS AND REASSESS THE RISK ASSESSMENT RESULTS AS POST MARKET FEEDBACK CONTINUES TO BECOME AVAILABLE. ADDITIONAL COMMENTS: BASED ON THE INFORMATION PROVIDED THAT THE USER HELD THE HANDLE SPOOL DURING ADVANCEMENT THROUGH THE ACCESSORY CHANNEL, A COOK REPRESENTATIVE HAS PROVIDED TRAINING TO THE MEDICAL FACILITY INVOLVED IN AN EFFORT TO PROMOTE FURTHER EDUCATION AND UNDERSTANDING RELATED TO APPROPRIATE USAGE OF THIS PRODUCT.

Description of Event or Problem · 0

DURING CLIP HEMOSTASIS AFTER A POLYPECTOMY, THE PHYSICIAN USED A COOK INSTINCT PLUS ENDOSCOPIC CLIPPING DEVICE. IT WAS REPORTED THAT THEY WANTED TO PLACED THE CLIP, BUT THEY SAW WITH THE CLIP, ALREADY INSERTED IN THE SCOPE (INSIDE THE PATIENT), HAD PARTIALLY DETACHED FROM THE RELEASE SYSTEM [MOVED IN A TROMBONING MOTION]. THEY WERE ABLE TO REMOVE IT WITHOUT PROBLEM AND PLACED ANOTHER CLIP. A SECTION OF THE DEVICE DID NOT REMAIN INSIDE THE PATIENT¿S BODY. THE PATIENT DID NOT REQUIRE ANY ADDITIONAL PROCEDURES DUE TO THIS OCCURRENCE. ACCORDING TO THE INITIAL REPORTER, THE PATIENT DID NOT EXPERIENCE ANY ADVERSE EFFECTS DUE TO THIS OCCURRENCE.

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
173249 INSTINCT PLUS ENDOSCOPIC CLIPPING DEVICE PKL, LIGATOR, HEMORRHOIDAL PKL WILSON-COOK MEDICAL INC W4807664 00827002580107

Patients

Seq Age Sex Outcome Treatment
1 NA Unknown SCOPE, UNKNOWN MAKE AND MODEL