NUTRILINE TWINFLO
Report
- Report Number
- 2245270-2024-00053
- Event Type
- Malfunction
- Date Received
- June 8, 2024
- Date of Event
- May 20, 2024
- Report Date
- July 24, 2024
- Manufacturer
- VYGON USA
- Product Code
- LJS
- PMA / PMN Number
- K052475
- Product Problem
- Yes
- Report Source
- Manufacturer report
- Reporter Location
- NE, US
- Reporter Occupation
- NURSE
- Health Professional
- Yes
Narratives
WE RECEIVED THE CATHETER AS A DEFECTIVE SAMPLE, WHICH INCLUDED AN ATTACHED NEEDLE-FREE CONNECTOR AND EXTENSION. THE CATHETER WAS SHORTENED TO A LENGTH OF 16 CM. THE DISTAL LUMEN OF THE CATHETER COULD NOT BE FLUSHED, WHILE THE PROXIMAL LUMEN WAS SUCCESSFULLY FLUSHED USING A 10 ML SYRINGE. UPON EXAMINATION OF THE CATHETER TUBE, A LEAKAGE WAS OBSERVED AT THE 29 CM MARK, WHERE FIBRIN RESIDUES WERE ALSO VISIBLE. DURING MICROSCOPIC EXAMINATION, A LEAKAGE WAS DETECTED JUST PROXIMAL TO THE 28.5 CM MARK. A SMALL LONGITUDINAL CUT WAS OBSERVED, LIKELY CAUSED BY A SHARP INSTRUMENT. THIS CUT APPEARS TO BE THE SOURCE OF THE LEAKAGE. A SMALL BLUE THREAD WAS ALSO VISIBLE AT THIS POINT. IT COULD NOT BE REMOVED FOR FURTHER EXAMINATION, BUT WE BELIEVE IT CAME THROUGH THE CATHETER TUBE DURING THE PROCEDURE. THERE ARE VARIOUS EVENTS THAT CAN LEAD TO A LEAKING CATHETER: 1. TENSILE FORCE-WHICH MAY BE CAUSED BY: DRESSING CHANGE - IN SOME INSTANCES, THE CATHETER CAN BECOME ADHERED TO THE DRESSING AND ADDITIONAL PULLING IS REQUIRED TO FREE IT. PLACING STRESS ON THE LINE COULD RESULT IN A TENSILE FRACTURE. FOR BABIES-ROUTINE CARE (WHEN LIFTING THE BABY TO CHANGE THE BEDDING) AND MOVEMENT OF THE BABY ITSELF COULD RESULT IN A TENSILE FRACTURE. 2. MECHANICAL DAMAGE BY A SHARP INSTRUMENT (FOR EXAMPLE SCISSORS, TOOTHED FORCEPS, OR SCALPEL) DURING DRESSING CHANGE. 3. ALCOHOL-BASED DISINFECTANT- CONCERNING THIS, THERE ARE SOME WARNINGS IN THE IFU: "BE AWARE THAT ORGANIC SOLVENTS SUCH AS ALCOHOL OR ACETONE MAY INTERACT WITH CATHETER MATERIAL AND WEAKEN IT." AND "AVOID ANY CONTACT OF THE CATHETER TUBING TO ALCOHOL CONTAINING DISINFECTANTS. THIS MAY IRREVERSIBLY DAMAGE THE CATHETER." A REVIEW OF THE BATCH HISTORY RECORDS FOR BATCHES 8212769,8210779 & 8150601 WAS PERFORMED, AND NO DEVIATIONS WERE FOUND. THE BATCHES COMPLIED WITH ITS SPECIFICATIONS AND WERE RELEASED. EACH CATHETER IS FLOW AND LEAK TESTED DURING PRODUCTION. THE TENSILE FORCE AND DIMENSIONS OF THE CATHETER/SET COMPONENTS ARE RANDOMLY CHECKED. INCOMING GOODS INSPECTIONS AND TWO 100% VISUAL TESTS AFTER PACKAGING ARE CONDUCTED DURING PRODUCTION. A TWO-YEAR REVIEW OF COMPLAINTS DATA BY VYGON USA INDICATES THAT THERE WERE EIGHT REPORTED COMPLAINTS FOR PRODUCT 1252.232G. ALL EIGHT COMPLAINTS ORIGINATED FROM THIS FACILITY. CORRECTIVE ACTION: AS THE CATHETER WORKED WELL FOR 42 DAYS (CATHETER IS INDICATED FOR USE UP TO 29 DAYS) BEFORE THE LEAKAGE OCCURRED, WE DO NOT BELIEVE THIS DEFECT IS MANUFACTURING RELATED. ANY MANUFACTURING PROBLEMS THAT WOULD LEAD TO A LEAK WOULD BE DETECTED BY THE USER WHEN INITIALLY FLUSHING THE CATHETER. THEREFORE, NO FURTHER CORRECTIVE ACTION WAS INITIATED BY QUALITY MANAGEMENT AT THIS TIME.
THE MALFUNCTIONING DEVICE WILL BE RETURNED TO VYGON FOR EVALUATION AS PART OF THE COMPLAINT INVESTIGATION. THE RESULTS OF THIS INVESTIGATION ARE PENDING AND WILL BE COMMUNICATED TO FDA WITHIN 30 DAYS OF ITS CONCLUSION VIA FOLLOW UP MDR.
DUAL LUMEN PICC PLACED (B)(6) 2024 AND BROKE (B)(6) 2024.
DUAL LUMEN PICC PLACED ON (B)(6) 2024 AND BROKE ON (B)(6) 2024.
Devices
| Seq | Brand | Generic | Product Code | Manufacturer | Model | Lot | UDI-DI |
|---|---|---|---|---|---|---|---|
| 2318865 | NUTRILINE TWINFLO | INTRAVASCULAR CATHETER | LJS | VYGON USA | 1252.232G | 23H002D |
Patients
| Seq | Age | Sex | Outcome | Treatment |
|---|---|---|---|---|
| 1 | NA | Unknown |