FDA Adverse Event
Injury
Summary report: N
SUNBEAM HEATING PAD
MDR report key: 1942053
·
Received December 23, 2010
Report
- Report Number
- MW5018709
- Event Type
- Injury
- Date Received
- December 23, 2010
- Date of Event
- December 20, 2010
- Report Date
- December 23, 2010
- Manufacturer
- SUNBEAM PRODUCTS, INC., JARDEN CONSUMER SOLUTIONS
- Product Code
- IRT
- Adverse Event
- Yes
- Product Problem
- Yes
- Report Source
- Voluntary report
- Reporter Location
- CA, US
- Reporter Occupation
- PHYSICIAN
Narratives
Description of Event or Problem · 1
HEATING PAD SHORTED OUT AT THE POINT OF ENTRY OF THE WALL CURRENT -20V- CORD INTO THE CONTROLLER OF THE HEATING PAD. SHORT PRODUCED A FLASH, HEAT, FLAME, AND BRIEF SHOCK TO THE PT, USER. DEVICE WAS PLUGGED INTO SURGE PROTECTOR, DEVICE TRIPPED AND CUT CURRENT STOPPING PROBLEM. THIS, I BELIEVE PREVENTED FOR AND OR ANY FURTHER INJURY. DOSE OR AMOUNT: MEDIUM SETTING. FREQUENCY: 20 MINUTES. ROUTE: CUTANEOUS. DATES OF USE: (B)(6) 2007 - (B)(6) 2010, SEVERAL TIMES A MONTH. DIAGNOSIS OR REASON FOR USE: MUSCLE PAIN. EVENT ABATED AFTER USE: YES.
Devices
| Seq | Brand | Generic | Product Code | Manufacturer | Model | Lot | UDI-DI |
|---|---|---|---|---|---|---|---|
| 1 | SUNBEAM HEATING PAD | HEATING PAD | IRT | SUNBEAM PRODUCTS, INC., JARDEN CONSUMER SOLUTIONS | 720 |
Patients
| Seq | Age | Sex | Outcome | Treatment |
|---|---|---|---|---|
| 1 | 55 YR | Life Threatening |