FDA Adverse Event Injury Summary report: N

MEDTRONIC ICD

MDR report key: 19410826 · Received May 28, 2024

Report

Report Number
2182208-2024-02248
Event Type
Injury
Date Received
May 28, 2024
Date of Event
January 16, 2024
Report Date
May 28, 2024
Manufacturer
MEDTRONIC, INC.
Product Code
DXY
Adverse Event
Yes
Product Problem
Yes
Report Source
Manufacturer report
Reporter Location
IR
Reporter Occupation
PHYSICIAN
Health Professional
Yes

Narratives

Additional Manufacturer Narrative · 0

THIS INFORMATION IS BASED ENTIRELY ON JOURNAL LITERATURE. MEDTRONIC WAS MADE AWARE OF THIS EVENT THROUGH A SEARCH OF LITERATURE PUBLICATIONS. THIS EVENT OCCURRED OUTSIDE THE US. PATIENT INFORMATION IS LIMITED DUE TO CONFIDENTIALITY CONCERNS. OF NOTE, MULTIPLE PATIENTS AND MULTIPLE MANUFACTURERS WERE NOTED IN THE ARTICLE; HOWEVER, A ONE-TO-ONE CORRELATION COULD NOT BE MADE WITH UNIQUE PRODUCT SERIAL/LOT NUMBERS. THE BASELINE GENDER/AGE CHARACTERISTICS IS MALE/62 YEARS OLD. THE MODEL LISTED IN THE REPORT IS A REPRESENTATIVE OF THE MODEL FAMILY, AS THERE IS NO SPECIFIC MODEL LISTED. WITHOUT A LOT NUMBER OR DEVICE SERIAL NUMBER, THE MANUFACTURING DATE CANNOT BE DETERMINED. SINCE NO DEVICE ID WAS PROVIDED, IT IS UNKNOWN IF THIS EVENT HAS BEEN PREVIOUSLY REPORTED. A REQUEST FOR ADDITIONAL INFORMATION WAS MADE. IF ADDITIONAL INFORMATION IS OBTAINED REGARDING THIS EVENT, IT WILL BE ADDED, AND A SUPPLEMENTAL REPORT WILL BE SUBMITTED ACCORDINGLY. REFERENCED ARTICLE: GLOBAL LONGITUDINAL STRAIN MAY BE THE ONE THAT APPROPRIATELY IDENTIFIES CANDIDATES OF ICD IMPLANTATION. HINDAWI CARDIOLOGY RESEARCH AND PRACTICE. VOLUME 2024, ARTICLE ID 2214072, 7 PAGES. DOI: 10.1155/2024/2214072. MEDTRONIC SUBMITS THIS REPORT TO COMPLY WITH FDA REGULATIONS 21 CFR PARTS 4 AND 803. MEDTRONIC HAS MADE REASONABLE EFFORTS TO PROVIDE AS MUCH RELEVANT INFORMATION AS IS AVAILABLE TO THE COMPANY AS OF THE SUBMISSION DATE OF THIS REPORT. THIS REPORT DOES NOT CONSTITUTE AN ADMISSION OR A CONCLUSION BY FDA, MEDTRONIC, OR ITS EMPLOYEES THAT THE DEVICE, MEDTRONIC, OR ITS EMPLOYEE CAUSED OR CONTRIBUTED TO THE EVENT DESCRIBED IN THE REPORT. ANY REQUIRED FIELDS THAT ARE UNPOPULATED ARE BLANK BECAUSE THE INFORMATION IS CURRENTLY UNKNOWN OR UNAVAILABLE. MEDTRONIC WILL SUBMIT A SUPPLEMENTAL REPORT IF ADDITIONAL RELEVANT INFORMATION BECOMES KNOWN.

Description of Event or Problem · 0

LITERATURE WAS REVIEWED REGARDING THE POTENTIAL OF GLOBAL LONGITUDINAL STRAIN (GLS) AS AN INDEX FOR PREDICTING FATAL ARRHYTHMIAS IN PATIENTS WITH HYPERTROPHIC CARDIOMYOPATHY (HCM). PATIENTS WERE CLASSIFIED INTO TWO GROUPS: THOSE WHO RECEIVED APPROPRIATE SHOCKS DUE TO SUSTAINED VENTRICULAR TACHYCARDIA (VT)/VENTRICULAR FIBRILLATION (VF), AND THOSE WHO RECEIVED INAPPROPRIATE SHOCKS WHICH INCLUDED ATRIAL TACHYCARDIA (AT), ATRIAL FIBRILLATION (AF), AND OTHER REASONS OR DID NOT RECEIVE ANY SHOCK AT ALL. THE AUTHORS DESCRIBED PATIENTS WHO EXPERIENCED INAPPROPRIATE THERAPY. THE STATUS OF THE DEVICES IS UNKNOWN. NO ADDITIONAL ADVERSE PATIENT EFFECTS OR PRODUCT PERFORMANCE ISSUES WERE REPORTED.

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
1837975 MEDTRONIC ICD IMPLANTABLE PACEMAKER PULSE-GENERATOR DXY MEDTRONIC, INC. MDT-ICD

Patients

Seq Age Sex Outcome Treatment
1 62 YR Male Life Threatening UNKNOWN COMPETITOR LEADS.