MITRIS RESLIA MITRAL VALVE
Report
- Report Number
- 2015691-2024-03912
- Event Type
- Injury
- Date Received
- May 24, 2024
- Date of Event
- April 15, 2024
- Report Date
- July 3, 2024
- Manufacturer
- EDWARDS LIFESCIENCES LLC
- Product Code
- LWR
- UDI-DI
- 00690103205565
- PMA / PMN Number
- P150048
- Adverse Event
- Yes
- Report Source
- Manufacturer report
- Reporter Location
- IL, US
- Reporter Occupation
- PHYSICIAN
- Health Professional
- Yes
Narratives
H11: ADDITIONAL MANUFACTURER NARRATIVE: THE INVESTIGATION IS STILL IN PROGRESS; THEREFORE, A CONCLUSION HAS YET TO BE ESTABLISHED. A SUPPLEMENTAL REPORT WILL BE SUBMITTED ACCORDINGLY UPON INVESTIGATION COMPLETION. EDWARDS WILL CONTINUE TO REVIEW AND MONITOR ALL REPORTED EVENTS. TRENDS ARE MONITORED ON A MONTHLY BASIS AND IF ACTION IS REQUIRED, APPROPRIATE INVESTIGATION WILL BE PERFORMED.
A DEVICE HISTORY RECORD (DHR) REVIEW WAS NOT PERFORMED, AS NO INFORMATION REGARDING A DEVICE FAILURE MODE WAS PROVIDED. FURTHERMORE, THERE IS NO ALLEGATION OF A MALFUNCTION WHICH COULD BE RELATED TO A MANUFACTURING NON-CONFORMANCE AND/OR ONE WAS NOT SUSPECTED OR CONFIRMED THROUGH INVESTIGATION; NO LABELING NON-CONFORMANCE/DEFICIENCY; NO DEVICE-RELATED INFECTION; AND NO EVIDENCE OF A PRODUCT FAILURE WITH REGARD TO DESIGN, RELIABILITY, OR USE ERROR. THE COMPLAINT INVESTIGATION WAS CONDUCTED, USING EVALUATION SUMMARY DOC-0212705 AND TRIAGE LEVEL 1, IN ACCORDANCE WITH TCA DOC-0226303 REV. E DUE DILIGENCE ATTEMPTS WERE MADE TO GATHER ADDITIONAL INFORMATION REGARDING A DEVICE FAILURE MODE, HOWEVER ADDITIONAL INFORMATION IS NOT AVAILABLE AT THIS TIME. PATIENT MEDICAL RECORDS WERE NOT PROVIDED BY THE HOSPITAL FOR REVIEW, OR THE MEDICAL RECORDS PROVIDED DO NOT CLARIFY THE DEVICE FAILURE MODE. PER THE INSTRUCTIONS FOR USE (IFU), REOPERATION/EXPLANT ARE KNOWN POTENTIAL ADVERSE EVENTS ASSOCIATED WITH BIOPROSTHETIC CARDIAC VALVES AND ANNULOPLASTY RINGS. IN THIS CASE, THERE IS NO EVIDENCE OF A MALFUNCTION WHICH COULD BE RELATED TO A MANUFACTURING NON-CONFORMANCE AND/OR ONE WAS NOT SUSPECTED OR CONFIRMED THROUGH INVESTIGATION; NO LABELING NON-CONFORMANCE/DEFICIENCY; NO USE-RELATED ISSUE WITH A HAZARDOUS SITUATION; NO DEVICE-RELATED INFECTION; AND NO EVIDENCE OF A PRODUCT FAILURE WITH REGARD TO DESIGN, RELIABILITY, OR USE ERROR. AS SUCH, NEITHER A PRODUCT RISK ASSESSMENT (PRA) NOR CORRECTIVE OR PREVENTIVE ACTIONS (CAPA/SCAR) ARE REQUIRED AT THIS TIME, PER DOC-0101337 AND DOC-0076862. BASED ON THE INFORMATION AVAILABLE, A DEFINITIVE ROOT CAUSE CANNOT BE CONCLUSIVELY DETERMINED. ALL PERTINENT INFORMATION AVAILABLE TO EDWARDS LIFESCIENCES HAS BEEN SUBMITTED.
IT WAS LEARNED THROUGH IMPLANT PATIENT REGISTRY THAT A 31MM 11400M MITRAL VALVE IN MITRAL POSITION WAS EXPLANTED AND REPLACED WITH ANOTHER 31MM 11400M AFTER AN IMPLANT DURATION OF TWO (2) MONTHS, 29 DAYS. REASON FOR REINTERVENTION WAS NOT PROVIDED. THE PATIENT WAS IN RECOVERY POST-OPERATIVE. EDWARDS LIFESCIENCES MAINTAINS AN IMPLANT PATIENT REGISTRY. THIS REGISTRY IS A PATIENT TRACKING MECHANISM FOR SERIALIZED EDWARDS IMPLANTABLE DEVICES (BIOPROSTHETIC HEART VALVES AND ANNULOPLASTY RINGS), RATHER THAN A TRUE POST-MARKET SURVEILLANCE REGISTRY. THROUGH THE REGISTRY, EDWARDS IS NOTIFIED WHEN THESE DEVICES ARE IMPLANTED. IN ADDITION, PATIENT AND/OR DEVICE STATUS MAY BE REPORTED TO THE REGISTRY VIA THE IMPLANTATION DATA CARDS. THE INFORMATION IS RECEIVED FROM VARIOUS SOURCES (E.G. SURGEON, HOSPITAL, AND PATIENT FAMILY MEMBERS) AND IS NOT RECEIVED IN THE FORM OF A CONVENTIONAL "CUSTOMER COMPLAINT". THE INFORMATION REPORTED MAY OR MAY NOT BE RELATED TO THE EDWARDS DEVICE.
Devices
| Seq | Brand | Generic | Product Code | Manufacturer | Model | Lot | UDI-DI |
|---|---|---|---|---|---|---|---|
| 663596 | MITRIS RESLIA MITRAL VALVE | HEART-VALVE, NON-ALLOGRAFT TISSUE | LWR | EDWARDS LIFESCIENCES LLC | 11400M | N/A | 00690103205565 |
Patients
| Seq | Age | Sex | Outcome | Treatment |
|---|---|---|---|---|
| 1 | 25 YR | Female | Life Threatening| H| R |