NV GXL LINR, NTRL, 28MM ID, GROUP 1 CUPS
Report
- Report Number
- 1038671-2024-01379
- Event Type
- Injury
- Date Received
- May 21, 2024
- Date of Event
- January 9, 2024
- Report Date
- February 13, 2025
- Manufacturer
- EXACTECH, INC.
- Product Code
- JDI
- UDI-DI
- 10885862022066
- PMA / PMN Number
- K070479
- Adverse Event
- Yes
- Product Problem
- Yes
- Report Source
- Manufacturer report
- Reporter Location
- OH, US
- Reporter Occupation
- PHYSICIAN
- Health Professional
- Yes
Narratives
THIS FOLLOW-UP REPORT IS BEING SUBMITTED TO RELAY ADDITIONAL AND/OR CORRECTED INFORMATION. THE MOST LIKELY UNDERLYING CAUSE FOR THE REVISION REPORTED IS PROSTHESIS WEAR AND LOOSENING AND A COMBINATION OF RISK FACTORS: SUCH AS USE ERROR, IMPLANT POSITIONING, IMPLANT SIZE SELECTION, AND PATIENT FACTORS (FITNESS FOR SURGERY, BIOMECHANICS, ACTIVITY LEVEL AND LOCAL TISSUE OXIDATION POTENTIAL). HOWEVER, THIS CANNOT BE CONFIRMED FROM THE REPORTED INFORMATION AND THE DEVICES WERE NOT AVAILABLE FOR EVALUATION. IF ANY FURTHER INFORMATION IS OBTAINED THAT WOULD CHANGE OR ALTER ANY INFORMATION PROVIDED, A SUPPLEMENTAL REPORT WILL BE FILED ACCORDINGLY.
CONCOMITANT DEVICES: 4193333 170-28-03 - BIOLOX DELTA FEMORAL HEAD 28MM OD, +3.5MM 4971780 180-65-20 - ALTEON 6.5MM SCREW, 20MM 5050846 186-01-50 - INTEGRIP CC, CLUSTER 50MM, G1 5332464 190-30-06 - ALT HA S CLR STD SZ 6 S002903 180-65-15 - ALTEON 6.5MM SCREW, 15MM. THE PRODUCT ASSOCIATED WITH THE REPORTED EVENT IS WITHIN THE SCOPE OF RECALL Z-1729-2022; HOWEVER, THERE IS INSUFFICIENT INFORMATION TO EVALUATE WHETHER THE SUBJECT ISSUE OF THE RECALL WAS THE CAUSE OR CONTRIBUTOR TO THE REPORTED EVENT. THE DEVICE WAS NOT RETURNED FOR EVALUATION AND NO MEDICAL OR OTHER RECORDS CONTAINING TREATMENT INFORMATION OR PATIENT INFORMATION HAVE BEEN RECEIVED; THEREFORE, THE REPORTED EVENT CANNOT BE CONFIRMED, NOR CAN THE CIRCUMSTANCES OR POTENTIAL CAUSES OR CONTRIBUTORS TO THE ALLEGED EVENT BE EVALUATED. SHOULD ADDITIONAL MATERIAL INFORMATION BECOME AVAILABLE THAT PERMITS MORE ANALYSIS OR CONCLUSIONS, A SUPPLEMENTAL REPORT WILL BE FILED ACCORDINGLY.
IT WAS REPORTED THAT APPROXIMATELY 65 MONTHS AFTER A RIGHT TOTAL HIP REPLACEMENT PROCEDURE, THE PATIENT UNDERWENT A REVISION PROCEDURE TO ADDRESS PROSTHESIS WEAR, PAIN, OSTEOLYTIC BONE LOSS, OSTEOLYTIC CHANGE, AND RECALLED POLYETHYLENE. REVISION SURGERY OPERATIVE NOTES WERE PROVIDED. PATIENT LEFT THE OPERATING ROOM IN STABLE CONDITION. POST OPERATIVE DIAGNOSIS NOTED WEAR OF THE IMPLANT. NO FURTHER ISSUES OR COMPLICATIONS WERE REPORTED. NO ADDITIONAL INFORMATION IS AVAILABLE.
Devices
| Seq | Brand | Generic | Product Code | Manufacturer | Model | Lot | UDI-DI |
|---|---|---|---|---|---|---|---|
| 584232 | NV GXL LINR, NTRL, 28MM ID, GROUP 1 CUPS | PROSTHESIS, HIP, SEMI-CONSTRAINED, METAL/POLYMER, CEMENTED | JDI | EXACTECH, INC. | 10885862022066 |
Patients
| Seq | Age | Sex | Outcome | Treatment |
|---|---|---|---|---|
| 1 | 65 YR | Female | Required Intervention| H | SEE H10. |