CARTO VIZIGO¿ 8.5F BI-DIRECTIONAL GUIDING SHEATH ¿ MEDIUM
Report
- Report Number
- 2029046-2024-01639
- Event Type
- Malfunction
- Date Received
- May 21, 2024
- Date of Event
- April 24, 2024
- Report Date
- August 6, 2024
- Manufacturer
- BIOSENSE WEBSTER INC
- Product Code
- DYB
- UDI-DI
- 10846835016277
- PMA / PMN Number
- K170997
- Product Problem
- Yes
- Report Source
- Manufacturer report
- Reporter Location
- BR
- Reporter Occupation
- PHYSICIAN
- Health Professional
- Yes
Narratives
E 1. INITIAL REPORTER PHONE : (B)(6). IF ADDITIONAL INFORMATION IS RECEIVED REGARDING THIS EVENT, A SUPPLEMENTAL 3500A REPORT WILL BE SUBMITTED TO THE FDA. THIS REPORT IS BEING SUBMITTED PURSUANT TO THE PROVISIONS OF 21 CFR, PART 803. THIS REPORT MAY BE BASED ON INFORMATION WHICH HAS NOT BEEN INVESTIGATED OR VERIFIED PRIOR TO THE REQUIRED REPORTING DATE. THIS REPORT DOES NOT REFLECT A CONCLUSION BY BIOSENSE WEBSTER, INC., OR ITS EMPLOYEES THAT THE REPORT CONSTITUTES AN ADMISSION THAT THE PRODUCT, BIOSENSE WEBSTER, INC., OR ITS EMPLOYEES CAUSED OR CONTRIBUTED TO THE POTENTIAL EVENT DESCRIBED IN THIS REPORT. IF INFORMATION IS OBTAINED THAT WAS NOT AVAILABLE FOR THE INITIAL REPORT, A FOLLOW-UP REPORT WILL BE FILED AS APPROPRIATE. MANUFACTURER'S REFERENCE NUMBER: (B)(4).
CORRECTION TO THE INITIAL REPORT: D4: FULL UDI HAS BEEN POPULATED TO FIELD D4. PRIMARY UDI NUMBER. G1. MANUFACTURING SITE. IS FREUDENBERG MEDICAL LLC, THEREFORE G1 MANUFACTURING SITE DETAILS HAVE BEEN UPDATED. INITIALLY, IT WAS REPORTED THAT THE VIZIGO¿ SHEATH SHOWED BLOOD BACKFLOW. IT WAS NOTICED THAT THE VALVE WAS NOT SEALING. THE SHEATH WAS REPLACED, AND THE PROCEDURE WAS SUCCESSFULLY COMPLETED. THERE WAS NO PATIENT CONSEQUENCE. THE DEVICE WAS RETURNED TO BIOSENSE WEBSTER (BWI) FOR EVALUATION. VISUAL INSPECTION AND MICROSCOPIC EXAMINATION OF THE RETURNED DEVICE WERE PERFORMED FOLLOWING BWI PROCEDURES. VISUAL ANALYSIS REVEALED THAT THE HEMOSTATIC VALVE WAS DISLODGED INSIDE OF THE HUB COMPONENT. A MICROSCOPIC EXAMINATION OF THE HEMOSTATIC VALVE SURFACE SHOWED STRESS MARKS ON THE OUTER DIAMETER. THE STRESS MARKS AND PHYSICAL DAMAGE OBSERVED SUGGEST THAT EXCESSIVE FORCE OR MANIPULATION WAS APPLIED; HOWEVER, THIS COULD NOT BE CONCLUSIVELY DETERMINED. A DEVICE HISTORY REVIEW WAS PERFORMED FOR THE FINISHED DEVICE 00002516 NUMBER, AND NO INTERNAL ACTION RELATED TO THE COMPLAINT WERE FOUND DURING THE REVIEW. THE LEAK ISSUE REPORTED BY THE CUSTOMER WAS CONFIRMED. THE DISLODGMENT OF THE VALVE IS RELATED TO THE FLUID LEAK ISSUE REPORTED BY THE CUSTOMER. THE POTENTIAL CAUSE OF THE ISSUE COULD BE RELATED TO THE INCORRECT INSERTION OF THE DILATOR INTO THE SHEATH CAUSING THE DISLODGMENT OF THE VALVE. THE INSTRUCTIONS FOR USE CONTAIN (IFU) THE FOLLOWING PRECAUTIONS: USE BEST PRACTICES FOR INSERTING OR RETRACTING ANY DEVICE AT THE HEMOSTATIC VALVE. MONITOR ANY POTENTIAL AIR ENTRAPPED AND COMPLETELY ASPIRATE ANY OBSERVED AIR OUT OF THE SIDE PORT. DO NOT REMOVE THE DILATOR OR CATHETER RAPIDLY. DAMAGE TO THE HEMOSTATIC VALVE MAY OCCUR. ONCE THE SHEATH IS INSERTED INTO THE VASCULATURE AND THE DILATOR IS REMOVED, ASPIRATE UNTIL STEADY BLOOD RETURN IS ACHIEVED PRIOR TO FLUSHING OR INFUSION. ALL FLUID INFUSION SHOULD BE THROUGH THE SIDE PORT. TO MINIMIZE THE RISK OF AIR EMBOLISM PROVIDE A CONTINUOUS INFUSION OF HEPARINIZED SALINE SOLUTION ONCE THE SHEATH IS INSERTED INTO THE PATIENT. SLOWLY REMOVE OR INSERT THE DILATOR OR OTHER DEVICES. AS PART OF THE QUALITY PROCESS, ALL DEVICES ARE MANUFACTURED, INSPECTED, AND RELEASED TO APPROVED SPECIFICATIONS. IF ADDITIONAL INFORMATION IS RECEIVED REGARDING THIS EVENT, A SUPPLEMENTAL 3500A REPORT WILL BE SUBMITTED TO THE FDA. MANUFACTURER'S REF. # (B)(4).
THE BIOSENSE WEBSTER, INC. PRODUCT ANALYSIS LAB RECEIVED THE DEVICE FOR EVALUATION. THE ANALYSIS HAS BEGUN BUT IS NOT COMPLETED AT THIS TIME. WHEN THE INVESTIGATIONAL ANALYSIS HAS BEEN COMPLETED, A SUPPLEMENTAL 3500A REPORT WILL BE SUBMITTED. IF ADDITIONAL INFORMATION IS RECEIVED REGARDING THIS EVENT, A SUPPLEMENTAL 3500A REPORT WILL BE SUBMITTED TO THE FDA. MANUFACTURER'S REFERENCE NUMBER: (B)(4).
IT WAS REPORTED THAT A PATIENT UNDERWENT AN ATRIAL FIBRILLATION (AFIB) ABLATION PROCEDURE WITH A CARTO VIZIGO¿ 8.5F BI-DIRECTIONAL GUIDING SHEATH ¿ MEDIUM AND AFTER INSERTION, THE VIZIGO¿ SHEATH SHOWED BLOOD BACKFLOW. IT WAS NOTICED THAT THE VALVE WAS NOT SEALING. THE SHEATH WAS REPLACED, AND THE PROCEDURE WAS SUCCESSFULLY COMPLETED. THERE WAS NO PATIENT CONSEQUENCE.