FDA Adverse Event Injury Summary report: N

PDS II POLYDIOXANONE SUTURE UNKNOWN PRODUCT

MDR report key: 19247605 · Received May 6, 2024

Report

Report Number
2210968-2024-05148
Event Type
Injury
Date Received
May 6, 2024
Date of Event
January 1, 2023
Report Date
May 6, 2024
Manufacturer
ETHICON INC.
Product Code
NEW
PMA / PMN Number
N18331
Adverse Event
Yes
Report Source
Manufacturer report
Reporter Location
JA
Reporter Occupation
OTHER

Narratives

Additional Manufacturer Narrative · 0

PRODUCT COMPLAINT (B)(4) THIS REPORT IS BEING SUBMITTED PURSUANT TO THE PROVISIONS OF 21 CFR, PART 803. THIS REPORT MAY BE BASED ON INFORMATION WHICH HAS NOT BEEN INVESTIGATED OR VERIFIED PRIOR TO THE REQUIRED REPORTING DATE. THIS REPORT DOES NOT REFLECT A CONCLUSION BY ETHICON INC, OR ITS EMPLOYEES THAT THE REPORT CONSTITUTES AN ADMISSION THAT THE PRODUCT, ETHICON INC, OR ITS EMPLOYEES CAUSED OR CONTRIBUTED TO THE POTENTIAL EVENT DESCRIBED IN THIS REPORT. IF INFORMATION IS OBTAINED THAT WAS NOT AVAILABLE FOR THE INITIAL REPORT, A FOLLOW-UP REPORT WILL BE FILED AS APPROPRIATE. ATTEMPTS ARE BEING MADE TO OBTAIN THE FOLLOWING INFORMATION. TO DATE NO RESPONSE HAS BEEN PROVIDED. IF FURTHER DETAILS ARE RECEIVED AT A LATER DATE A SUPPLEMENTAL MEDWATCH WILL BE SENT. DOES THE SURGEON BELIEVE THAT ANY OF THE ETHICON PRODUCTS INVOLVED CAUSED AND/OR CONTRIBUTED TO THE POST-OPERATIVE COMPLICATIONS DESCRIBED IN THE ARTICLE? WHICH SPECIFIC ETHICON PRODUCTS HAVE BEEN USED DURING THE PROCEDURES (PRODUCT CODE, LOT NUMBER)? DOES THE SURGEON BELIEVE THERE WAS ANY DEFICIENCY WITH ANY OF THE ETHICON PRODUCTS USED IN THIS PROCEDURE? IF SO, PLEASE PROVIDE DETAILS. WERE THE CASES DISCUSSED IN THIS ARTICLE PREVIOUSLY REPORTED TO ETHICON? IF YES, PLEASE PROVIDE A COMPLAINT REFERENCE NUMBER. PATIENT DEMOGRAPHICS? THIS REPORT IS RELATED TO A JOURNAL ARTICLE; THEREFORE, NO PRODUCT WILL BE RETURNED FOR ANALYSIS AND THE BATCH HISTORY RECORDS CANNOT BE REVIEWED AS THE LOT NUMBER HAS NOT BEEN PROVIDED. H6 COMPONENT CODE: G07002 ¿ DEVICE NOT RETURNED THE SINGLE COMPLAINT WAS REPORTED WITH MULTIPLE EVENTS. THERE ARE NO ADDITIONAL DETAILS REGARDING THE ADDITIONAL EVENTS. RELATED EVENTS CAPTURED VIA 2210968-2024-05147 CITATION: DISEASES OF THE ESOPHAGUS (2023), 36, 1¿7. HTTPS://DOI.ORG/10.1093/DOTE/DOAC066.

Description of Event or Problem · 0

TITLE: COMPARISON OF HAND-SEWN AND CIRCULAR STAPLED ESOPHAGOGASTRIC ANASTOMOSES IN THE NECK AFTER ESOPHAGECTOMY FOR THORACIC ESOPHAGEAL CANCER: A PROPENSITY SCORE-MATCHED ANALYSIS THE AIM OF THIS RETROSPECTIVE STUDY IS TO COMPARE SHORT-TERM RESULTS (ANASTOMOTIC LEAKAGE AND STRICTURE)BETWEEN CIRCULAR STAPLED ANASTOMOSIS (CS) AND HAND-SEWN ANASTOMOSIS (HS) BY PERFORMING A PROPENSITY SCORE-MATCHED (PSM) ANALYSIS TO ALIGN PATIENT BACKGROUNDS. A TOTAL OF 341 PATIENTS (284 MALES AND 57 FEMALES; MEAN AGE WAS 64.5±8.2 YEARS) WHO UNDERWENT ESOPHAGECTOMY BETWEEN (B)(6) 2009 AND (B)(6) 2019 WERE INCLUDED IN THE STUDY. THE ANASTOMOSIS METHOD WAS CHANGED FROM CIRCULAR STAPLED ANASTOMOSIS TO HAND-SEWN ANASTOMOSIS IN (B)(6) 2014 TO REDUCE THE RISK OF ANASTOMOTIC LEAKAGE. FOR THE CS GROUP, COMPETITOR STAPLER WAS USED. IN THE HS GROUP, THE OUTER ROW OF THE ANASTOMOSIS WAS MADE WITH INTERRUPTED SUTURES USING AN ABSORBABLE POLYGLACTIN THREAD (3-0 VICRYL PLUS, ETHICON, INC., SOMERVILLE, NJ, USA) ACROSS THE LONGITUDINAL MUSCLE FIBERS OF THE ESOPHAGUS. THE MUCOSA OF THE ESOPHAGUS AND STOMACH WERE THEN APPROXIMATED WITH CONTINUOUS SUTURES USING ABSORBABLE POLYDIOXANONE THREAD (4¿0 PDS II, ETHICON, INC.). REPORTED COMPLICATIONS INCLUDE ANASTOMOTIC LEAKAGE (N=25) AND ANASTOMOTIC STRICTURE (N=37). IN CONCLUSION, FOR ESOPHAGOGASTRIC ANASTOMOSIS IN THE NECK AFTER ESOPHAGECTOMY, HS IS SUPERIOR TO CS WITH REGARD TO ANASTOMOTIC LEAKAGE.

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
522129 PDS II POLYDIOXANONE SUTURE UNKNOWN PRODUCT SUTURE, SURGICAL, ABSORBABLE NEW ETHICON INC.

Patients

Seq Age Sex Outcome Treatment
1 NA Unknown Required Intervention