FDA Adverse Event Malfunction Summary report: N

FLEXION PERMANENT PACING LEAD

MDR report key: 19223002 · Received May 1, 2024

Report

Report Number
1035166-2024-00046
Event Type
Malfunction
Date Received
May 1, 2024
Date of Event
November 2, 2006
Report Date
May 1, 2024
Manufacturer
OSCOR INC.
Product Code
DTB
PMA / PMN Number
K964107
Product Problem
Yes
Report Source
Manufacturer report
Reporter Location
MN, US
Reporter Occupation
003

Narratives

Additional Manufacturer Narrative · 0

THE DEVICE IMPLANT DATE IS (B)(6) 2001. THE DEVICE WAS IN SERVICE FOR APPROXIMATELY 5 YEARS, 8 MONTHS BEFORE BEING ABANDONED/CAPPED ON (B)(6) 2006. BASED UPON THE IMPLANT DATE OF THIS LEAD (2001) THE DEVICE HISTORY RECORD FOR THIS LEAD MODEL IS BEYOND OSCOR'S RECORD RETENTION PERIOD. INSPECTION PROCEDURES REQUIRE ANY OSCOR PRODUCT TO PASS ALL IN-PROCESS AND QA FINAL INSPECTION BEFORE SHIPPING TO THE CUSTOMER. NO PRODUCT WAS RETURNED TO OSCOR INC. FOR EVALUATION; HOWEVER, A COMPLAINT NOTIFICATION WAS PROVIDED. WITHOUT THE RETURN OF THE ACTUAL DEVICE IN QUESTION FOR EVALUATION, OSCOR INC. IS UNABLE TO DETERMINE THE EXACT CAUSE FOR THIS INCIDENT. AT THIS TIME, IT IS NOT POSSIBLE TO ASSIGN A DEFINITIVE ROOT CAUSE FOR THE EVENT AS REPORTED. THE COMPLAINT IS NON-VERIFIABLE AS THE PRODUCT WAS NOT RETURNED FOR EVALUATION.

Description of Event or Problem · 0

(B)(6) 2024: THE CUSTOMER REPORTED THAT LEAD 4018/BIQ20744 WAS CAPPED ON (B)(6) 2006 DUE TO PRODUCT PERFORMANCE ISSUE. (B)(6) 2024: ADDITIONAL DETAILS PROVIDED UNDER COMPLAINT #(B)(4); BOSTON SCIENTIFIC RECEIVED INFORMATION THAT DURING A ROUTINE PACEMAKER CHANGEOUT PROCEDURE THIS VENTRICULAR LEAD WAS SURGICALLY ABANDONED DUE TO THE IMPEDANCE MEASUREMENTS DECREASING FROM 440 OHMS, A YEAR AGO, TO 200 OHMS, WITH HIGH THRESHOLD MEASUREMENTS. THE SENSING FUNCTION WAS STABLE. THE TECHNICAL SERVICES CONSULTANT SUSPECTED AN OUTER INSULATION ISSUE WITH THE REPORTED MEASUREMENTS. THE LEAD WAS SURGICALLY ABANDONED. A NEW LEAD WAS SUCCESSFULLY IMPLANTED. THE ABANDONED LEAD WILL NOT BE RETURNED FOR ANALYSIS; THEREFORE, BOSTON SCIENTIFIC CANNOT CONFIRM THIS CLINICAL OBSERVATION. IMPEDANCE GONE FROM 440 LAST YEAR TO 200 THIS YEAR ALONG WITH HIGH THRESHOLDS, SENSING STABLE. RESPONSE SUSPECTS OUTER INSULATION ISSUE WITH OVERALL IMPEDANCE LOW AND DROP FROM LAST YEAR. SUGGESTED UNIPOLAR TESTING TO EVAL THRESHOLDS IN UNIPOLAR AS WELL AS IF BETTER IMPEDANCES.

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
2134701 FLEXION PERMANENT PACING LEAD PERMANENT PACEMAKER ELECTRODE DTB OSCOR INC. 4018

Patients

Seq Age Sex Outcome Treatment
1 NA Unknown Required Intervention