LAP-BAND AP ADJUSTABLE GASTRIC BANDING SYSTEM (STANDARD)
Report
- Report Number
- 2024601-2010-00999
- Event Type
- Injury
- Date Received
- December 8, 2010
- Date of Event
- November 1, 2010
- Report Date
- November 10, 2010
- Manufacturer
- ALLERGAN
- Product Code
- LTI
- PMA / PMN Number
- P000008
- Adverse Event
- Yes
- Report Source
- Manufacturer report
- Reporter Location
- TN, US
- Reporter Occupation
- OTHER
Narratives
TAPER II. (B)(4). THE REPORTER OF THE COMPLAINT WAS ASKED TO RETURN THE PRODUCT FOR ANALYSIS. THE DEVICE HAS NOT YET BEEN RECEIVED BY ALLERGAN. BASED UPON THE MODEL NUMBER, SERIAL NUMBER AND IMPLANT DATE PROVIDED BY THE REPORTER, THE CONNECTOR TYPE IS ASSUMED TO BE A TAPER II. VISUAL EXAMINATION MAY DETERMINE THE CONNECTOR TYPE ASSOCIATED WITH THIS REPORT. EROSION, VOMITING, AND PAIN ARE SURGICAL/PHYSIOLOGICAL COMPLICATIONS, AND ANALYSIS OF DEVICE GENERALLY DOES NOT ASSIST ALLERGAN IN DETERMINING A PROBABLE CAUSE FOR THESE EVENTS. DEVICE LABELING ADDRESSES THE REPORTED EVENT OF EROSION AS FOLLOWS: "AS WITH OTHER GASTROPLASTY SURGERIES, PARTICULAR CARE MUST BE TAKEN DURING DISSECTION AND DURING IMPLANTATION OF THE DEVICE TO AVOID DAMAGE TO THE GASTROINTESTINAL TRACT. ANY DAMAGE TO THE STOMACH DURING THE PROCEDURE MAY RESULT IN EROSION OF THE DEVICE INTO THE GI TRACT." "OVER-DISSECTION OF THE STOMACH DURING PLACEMENT MAY RESULT IN SLIPPAGE OR EROSION OF THE BAND AND REQUIRE REOPERATION." "THERE IS A RISK OF BAND EROSION INTO STOMACH TISSUE. EROSION OF THE BAND INTO STOMACH TISSUE HAS BEEN ASSOCIATED WITH REVISION SURGERY AFTER THE USE OF GASTRIC-IRRITATING MEDICATIONS, AFTER STOMACH DAMAGE AND AFTER EXTENSIVE DISSECTION OR USE OF ELECTROCAUTERY, AND DURING EARLY EXPERIENCE." DEVICE LABELING ADDRESSES THE REPORTED EVENTS OF VOMITING AS FOLLOWS: "VOMITING MAY OCCUR, PARTICULARLY IN THE FIRST FEW DAYS AFTER SURGERY AND WHEN THE PT EATS MORE THAN RECOMMENDED." DEVICE LABELING ADDRESSES THE REPORTED EVENT OF PAIN AS FOLLOWS: "OTHER ADVERSE EVENTS CONSIDERED RELATED TO THE LAP-BAND SYSTEM THAT OCCURRED IN FEWER THAN 1% OF SUBJECTS INCLUDED: ESOPHAGITIS, GASTRITIS, HIATAL HERNIA, PANCREATITIS, ABDOMINAL PAIN, HERNIA, INCISIONAL INFECTION..."
DOCTOR REPORTED EVENTS OF "PAIN, EROSION AND VOMIT." DOCTOR PERFORMED A SURGERY TO EXPLANT THE DEVICE.
Devices
| Seq | Brand | Generic | Product Code | Manufacturer | Model | Lot | UDI-DI |
|---|---|---|---|---|---|---|---|
| 1 | LAP-BAND AP ADJUSTABLE GASTRIC BANDING SYSTEM (STANDARD) | LTI | ALLERGAN | NA | 1470372 |
Patients
| Seq | Age | Sex | Outcome | Treatment |
|---|---|---|---|---|
| 1 | NI | Hospitalization| R |