FDA Adverse Event Injury Summary report: N

ACHIEVE MAPPING CATHETER - 20 MM

MDR report key: 19183500 · Received April 25, 2024

Report

Report Number
9617601-2024-00070
Event Type
Injury
Date Received
April 25, 2024
Date of Event
April 17, 2023
Report Date
April 25, 2024
Manufacturer
MEDTRONIC MEXICO S. DE R.L. DE CV
Product Code
DRF
PMA / PMN Number
K102588
Adverse Event
Yes
Report Source
Manufacturer report
Reporter Location
BE
Reporter Occupation
OTHER HEALTH CARE PROFESSIONAL
Health Professional
Yes

Narratives

Additional Manufacturer Narrative · 0

THIS INFORMATION IS BASED ENTIRELY ON JOURNAL LITERATURE. MEDTRONIC WAS MADE AWARE OF THIS EVENT THROUGH A SEARCH OF LITERATURE PUBLICATIONS. THIS EVENT OCCURRED OUTSIDE THE US. PATIENT INFORMATION IS LIMITED DUE TO CONFIDENTIALITY CONCERNS. OF NOTE, MULTIPLE PATIENTS AND MULTIPLE MANUFACTURERS WERE NOTED IN THE ARTICLE; HOWEVER, A ONE-TO-ONE CORRELATION COULD NOT BE MADE WITH UNIQUE PRODUCT SERIAL/LOT NUMBERS. THE BASELINE GENDER/AGE CHARACTERISTICS IS MALE/64 YEARS OLD. WITHOUT A LOT NUMBER OR DEVICE SERIAL NUMBER, THE MANUFACTURING DATE CANNOT BE DETERMINED. SINCE NO DEVICE ID WAS PROVIDED, IT IS UNKNOWN IF THIS EVENT HAS BEEN PREVIOUSLY REPORTED. REFERENCED ARTICLE: THE ABSENCE OF REAL-TIME PULMONARY VEIN ISOLATION DURING CRYOBALLOON ABLATION IS ASSOCIATED WITH ATRIAL FIBRILLATION RECURRENCE AND PULMONARY VEIN RECONNECTION. JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY. 2023. 66: 2091¿2101. DOI: 10.1007/S10840-023-01538-4 MEDTRONIC SUBMITS THIS REPORT TO COMPLY WITH FDA REGULATIONS 21 CFR PARTS 4 AND 803. MEDTRONIC HAS MADE REASONABLE EFFORTS TO PROVIDE AS MUCH RELEVANT INFORMATION AS IS AVAILABLE TO THE COMPANY AS OF THE SUBMISSION DATE OF THIS REPORT. THIS REPORT DOES NOT CONSTITUTE AN ADMISSION OR A CONCLUSION BY FDA, MEDTRONIC, OR ITS EMPLOYEES THAT THE DEVICE, MEDTRONIC, OR ITS EMPLOYEE CAUSED OR CONTRIBUTED TO THE EVENT DESCRIBED IN THE REPORT. ANY REQUIRED FIELDS THAT ARE UNPOPULATED ARE BLANK BECAUSE THE INFORMATION IS CURRENTLY UNKNOWN OR UNAVAILABLE. MEDTRONIC WILL SUBMIT A SUPPLEMENTAL REPORT IF ADDITIONAL RELEVANT INFORMATION BECOMES KNOWN.

Description of Event or Problem · 0

LITERATURE WAS REVIEWED REGARDING CRYOBALLOON ABLATION (CBA) OF ATRIAL FIBRILLATION (AF). THE AUTHORS DESCRIBED THREE PATIENTS WHO EXPERIENCED PERMANENT SEQUELAE POST ABLATION; TWO PATIENTS HAD A PHRENIC NERVE INJURY THAT PERSISTED, AND ONE PATIENT HAD MILD DYSARTHRIA WITH LEFT HEMIPLEGIA DUE TO A STROKE. THERE WERE OTHER PATIENTS WITH UNKNOWN COMPLICATIONS, BUT MOST OF THEM RESOLVED COMPLETELY AFTER TREATMENT. THE STATUS OF THE CATHETERS AND SHEATHS IS UNKNOWN. NO ADDITIONAL ADVERSE PATIENT EFFECTS WERE REPORTED.

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
1605176 ACHIEVE MAPPING CATHETER - 20 MM CATHETER, ELECTRODE RECORDING, OR PROBE, ELECT DRF MEDTRONIC MEXICO S. DE R.L. DE CV 990063-020

Patients

Seq Age Sex Outcome Treatment
1 64 YR Male Required Intervention