TIBIAL INSERT FB SZ 1 RT 6MM
Report
- Report Number
- 1038671-2024-00980
- Event Type
- Injury
- Date Received
- April 25, 2024
- Date of Event
- February 21, 2024
- Report Date
- January 31, 2025
- Manufacturer
- EXACTECH, INC.
- Product Code
- HSN
- UDI-DI
- 10885862276339
- PMA / PMN Number
- K152217
- Removal / Correction Number
- Z-0024-2022
- Adverse Event
- Yes
- Product Problem
- Yes
- Report Source
- Manufacturer report
- Reporter Location
- NY, US
- Reporter Occupation
- PHYSICIAN
- Health Professional
- Yes
Narratives
THIS FOLLOW-UP REPORT IS BEING SUBMITTED TO RELAY ADDITIONAL AND/OR CORRECTED INFORMATION. THE REASON FOR THE REVISION REPORTED CANNOT BE CONFIRMED FROM THE INFORMATION PROVIDED BUT MAY BE THE RESULT OF PROSTHESIS WEAR AND/OR DUE TO INCLUSION OF THE POLYETHYLENE IN THE PACKAGING RECALL. POTENTIAL CONTRIBUTIONS OF USER AND PATIENT-RELATED CONSIDERATIONS TO THE EVENT COULD NOT BE ASSESSED AS THE DEVICES WERE NOT AVAILABLE FOR EVALUATION AND IMAGES AND RADIOGRAPHS WERE NOT PROVIDED. THE PRODUCT ASSOCIATED WITH THE REPORTED EVENT IS WITHIN THE SCOPE OF RECALL Z-0024-2022; HOWEVER, THERE IS INSUFFICIENT INFORMATION TO EVALUATE WHETHER THE SUBJECT ISSUE OF THE RECALL WAS A CAUSE OR CONTRIBUTOR TO THE REPORTED EVENT. IF ANY FURTHER INFORMATION IS OBTAINED THAT WOULD CHANGE OR ALTER ANY INFORMATION PROVIDED, A SUPPLEMENTAL REPORT WILL BE FILED ACCORDINGLY."
D10: CONCOMITANT DEVICES: 5811135 350-02-01 - TALAR IMPLANT SZ 1 RT. 5969045 350-10-02 - ANKLE SZ 2 LOCKING CLIP. 6107919 350-12-02 - TIBIAL PLATE FB SZ 2 RT. H3: THE REVISION REPORTED WAS LIKELY THE RESULT OF PROSTHESIS WEAR OF THE TIBIAL INSERT. THE CAUSE OF PROSTHESIS WEAR IS GENERALLY A COMBINATION OF RISK FACTORS INCLUDING USE ERROR, IMPLANT POSITIONING, IMPLANT SIZE SELECTION, AND PATIENT FACTORS. HOWEVER, THIS CANNOT BE CONCLUSIVELY DETERMINED WITH THE INFORMATION PROVIDED.
AS REPORTED VIA LEGAL DOCUMENTATION, A PATIENT HAD A RIGHT ANKLE REPLACEMENT PROCEDURE ON (B)(6) 2019 AND THEN WAS REVISED ON (B)(6) 2024. THE PATIENT REQUIRED REVISION SURGERY FOR ISSUES INCLUDING BUT NOT LIMITED TO POLYETHYLENE PROSTHESIS WEAR. THE MOSTLY LIKELY CAUSE FOR THE REVISION REPORTED DUE TO PROSTHESIS WEAR IS A COMBINATION OF RISK FACTORS INCLUDING USE ERROR, IMPLANT POSITIONING, IMPLANT SIZE SELECTION, AND PATIENT FACTORS. HOWEVER, THIS CANNOT BE CONCLUSIVELY DETERMINED WITH THE INFORMATION PROVIDED.
Devices
| Seq | Brand | Generic | Product Code | Manufacturer | Model | Lot | UDI-DI |
|---|---|---|---|---|---|---|---|
| 855299 | TIBIAL INSERT FB SZ 1 RT 6MM | PROSTHESIS, ANKLE, SEMI-CONSTRAINED, CEMENTED, METAL/POLYMER | HSN | EXACTECH, INC. | 10885862276339 |
Patients
| Seq | Age | Sex | Outcome | Treatment |
|---|---|---|---|---|
| 1 | 62 YR | Female | Hospitalization| R | SEE H10. |