FDA Adverse Event Injury Summary report: N

SURGICEL ABSORBABLE HEMOSTAT UNKNOWN

MDR report key: 19176310 · Received April 24, 2024

Report

Report Number
2210968-2024-04853
Event Type
Injury
Date Received
April 24, 2024
Date of Event
May 17, 2023
Report Date
April 24, 2024
Manufacturer
ETHICON INC.
Product Code
LMG
PMA / PMN Number
N12159
Adverse Event
Yes
Report Source
Manufacturer report
Reporter Location
IN
Reporter Occupation
PHYSICIAN
Health Professional
Yes

Narratives

Additional Manufacturer Narrative · 0

PRODUCT COMPLAINT # (B)(4). H6. COMPONENT CODE: G07002 - DEVICE NOT RETURNED. THIS REPORT IS RELATED TO A JOURNAL ARTICLE, THEREFORE NO PRODUCT WILL BE RETURNED FOR ANALYSIS AND THE MANUFACTURING RECORD EVALUATION CANNOT BE REVIEWED AS THE LOT NUMBER HAS NOT BEEN PROVIDED. CITATION: INDIAN JOURNAL OF OTOLARYNGOLOGY AND HEAD & NECK SURGERY (2023) 75:2814¿2822; HTTPS://DOI.ORG/10.1007/S12070-023-03866-3. THIS REPORT IS BEING SUBMITTED PURSUANT TO THE PROVISIONS OF 21 CFR, PART 803. THIS REPORT MAY BE BASED ON INFORMATION WHICH HAS NOT BEEN INVESTIGATED OR VERIFIED PRIOR TO THE REQUIRED REPORTING DATE. THIS REPORT DOES NOT REFLECT A CONCLUSION BY ETHICON, OR ITS EMPLOYEES THAT THE REPORT CONSTITUTES AN ADMISSION THAT THE PRODUCT, ETHICON, OR ITS EMPLOYEES CAUSED OR CONTRIBUTED TO THE POTENTIAL EVENT DESCRIBED IN THIS REPORT. IF INFORMATION IS OBTAINED THAT WAS NOT AVAILABLE FOR THE INITIAL REPORT, A FOLLOW-UP REPORT WILL BE FILED AS APPROPRIATE.

Description of Event or Problem · 0

IT WAS REPORTED VIA A JOURNAL ARTICLE: TITLE: OUR EXPERIENCE IN TRANS NASAL ENDOSCOPIC REPAIR OF ANTERIOR SKULL BASE DEFECTS REINFORCED WITH MULTIPLE LAYERS OF GRAFT MATERIALS AUTHOR(S): YETHIN YEDUKUMAR, RAHUL GUPTA, YAMINI PATEL, R. G. AIYER CITATION: INDIAN JOURNAL OF OTOLARYNGOLOGY AND HEAD & NECK SURGERY (2023) 75:2814¿2822; HTTPS://DOI.ORG/10.1007/S12070-023-03866-3. THIS STUDY AIMS TO DETERMINE THE BEST TECHNIQUE TO REPAIR ANTERIOR SKULL BASE DEFECTS USING VARIOUS GRAFTS. BETWEEN MAY 2019 TO OCTOBER 2021, 17 PATIENTS WHO UNDERWENT ENDOSCOPIC REPAIR OF ANTERIOR SKULL BASE DEFECTS USING VARIOUS GRAFTS WERE INCLUDED IN THE STUDY. THERE WERE 6 MALES AND 11 FEMALES. THE MAJORITY WERE OF THE AGE GROUP 40¿59 YEARS (7 PATIENTS). THE SECOND MOST COMMON AGE GROUP WAS 20¿39 YEARS (6 PATIENTS). THE LEAST COMMON AGE GROUP WAS 0¿19 YEARS (1 PATIENT). 3 PATIENTS WERE OF THE ELDERLY AGE GROUP (= 60YEARS). DURING THE PROCEDURE, AFTER INDUCING THE PATIENT, NASAL ENDOSCOPY WAS DONE WITH O DEGREE ENDOSCOPE OF STORZ. THE SITE OF THE LEAK AND ANTERIOR SKULL BASE DEFECT WAS IDENTIFIED. BIPOLAR CAUTERIZATION IS DONE OVER THAT AREA. DEFECT CLOSURE IS DONE WITH MULTIPLE LAYERS OF GRAFTS. VARIOUS GRAFT MATERIALS USED IN THE STUDY WERE FASCIA LATA IN 14 PATIENTS, THIGH FAT IN 14 PATIENTS, HADAD FLAP IN 8 PATIENTS, SEPTAL CARTILAGE IN 1 PATIENT, NASAL SEPTAL BONE CHIP IN 2 PATIENTS, SEPTAL MUCOSAL FREE FLAP IN 1 PATIENT, SURGICEL (ETHICON) IN 10 PATIENTS AND FIBRIN GLUE 5 PATIENTS. AFTER CHECKING FOR CEREBROSPINAL FLUID LEAK AND AFTER ATTAINING HAEMOSTASIS, BILATERAL BACTERIOSTATIC MEROCELE WAS KEPT. THE EXTERNAL NASAL DRESSING WAS GIVEN. MULTIPLE LAYERS OF GRAFT MATERIALS WERE USED IN ALL PATIENTS FOR EXTRA SUPPORT. REPORTED COMPLICATIONS INCLUDED CEREBROSPINAL FLUID LEAK WITH RHINORRHEA (N=1) AND CONVULSION DUE TO CEREBRAL EDEMA (N=?). IN CONCLUSION, THE SUCCESS OF ANTERIOR SKULL BASE DEFECT REPAIR DEPENDS ON WATERTIGHT DURAL CLOSURE WITH MULTIPLE LAYERS OF GRAFTS TO PREVENT POSTOPERATIVE CEREBROSPINAL FLUID LEAK. ALTHOUGH DEPENDENT ON THE SURGEON¿S PREFERENCE, USUALLY THE SEQUENCE OF AN UNDERLAY FAT - FASCIA LATA - OVERLAY FAT FOLLOWED BY GLUE/GEL FOAM/HADAD FLAP WORKS WELL. EVEN AFTER DISCHARGING THE PATIENT, REGULAR FOLLOW-UP AND EVALUATION ENSURE THAT THE GRAFT IS IN SITU AND THERE IS NO CEREBROSPINAL FLUID LEAK OR OTHER COMPLICATION.

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
583538 SURGICEL ABSORBABLE HEMOSTAT UNKNOWN AGENT, ABSORBABLE HEMOSTATIC, NON-COLLAGEN BASED LMG ETHICON INC.

Patients

Seq Age Sex Outcome Treatment
1 NA Unknown Other