CARTO VIZIGO¿ 8.5F BI-DIRECTIONAL GUIDING SHEATH - SMALL
Report
- Report Number
- 2029046-2024-01342
- Event Type
- Malfunction
- Date Received
- April 23, 2024
- Date of Event
- April 1, 2024
- Report Date
- April 23, 2024
- Manufacturer
- BIOSENSE WEBSTER INC
- Product Code
- DYB
- UDI-DI
- 10846835016253
- PMA / PMN Number
- K170997
- Product Problem
- Yes
- Report Source
- Manufacturer report
- Reporter Location
- CH
- Reporter Occupation
- OTHER
- Health Professional
- N
Narratives
THIS REPORT IS BEING SUBMITTED PURSUANT TO THE PROVISIONS OF 21 CFR, PART 803. THIS REPORT MAY BE BASED ON INFORMATION WHICH HAS NOT BEEN INVESTIGATED OR VERIFIED PRIOR TO THE REQUIRED REPORTING DATE. THIS REPORT DOES NOT REFLECT A CONCLUSION BY BIOSENSE WEBSTER, INC., OR ITS EMPLOYEES THAT THE REPORT CONSTITUTES AN ADMISSION THAT THE PRODUCT, BIOSENSE WEBSTER, INC. OR ITS EMPLOYEES CAUSED OR CONTRIBUTED TO THE POTENTIAL EVENT DESCRIBED IN THIS REPORT. IF INFORMATION IS OBTAINED THAT WAS NOT AVAILABLE FOR THE INITIAL REPORT, A FOLLOW-UP REPORT WILL BE FILED AS APPROPRIATE. MANUFACTURER'S REFERENCE NUMBER: (B)(4).
IT WAS REPORTED THAT A PATIENT UNDERWENT A SUPRAVENTRICULAR TACHYCARDIA ABLATION PROCEDURE WITH A CARTO VIZIGO¿ 8.5F BI-DIRECTIONAL GUIDING SHEATH - SMALL AND WHEN FLUSHING THE SHEATH, FLUID (SALINE SOLUTION) ESCAPED FROM THE THREE-WAY STOPCOCK. THE ISSUE WAS NOTED AT THE HUB AREA. HOWEVER, THERE WAS NO HEMOSTATIC VALVE/BRIM CAP/HUB DAMAGE NOTED. THERE WAS NO BLOOD RETURN IDENTIFIED. A SECOND DEVICE WAS USED TO COMPLETE THE OPERATION. THERE WAS NO ADVERSE EVENT REPORTED ON PATIENT. DEVICE EVALUATION DETAILS: ON 8-MAY-2024, THE DEVICE WAS RETURNED TO BIOSENSE WEBSTER INC (BWI) FOR EVALUATION AND THE EVALUATION HAS BEEN COMPLETED. VISUAL INSPECTION, BACK PRESSURE TEST, AND MICROSCOPIC EXAMINATION OF THE RETURNED DEVICE WERE PERFORMED FOLLOWING BWI PROCEDURES. VISUAL ANALYSIS OF THE RETURNED SAMPLE REVEALED THAT NO DAMAGE WAS OBSERVED. MICROSCOPIC EXAMINATION OF THE HEMOSTATIC VALVE SURFACE DOES NOT SHOW STRESS MARKS ON THE OUTER DIAMETER. A BACK PRESSURE TEST WAS PERFORMED, AND NO ISSUES WERE OBSERVED. A DEVICE HISTORY RECORD WAS PERFORMED, AND NO INTERNAL ACTIONS RELATED TO THE REPORTED COMPLAINT WERE IDENTIFIED. THERE WAS NO LEAKAGE AND NO BUBBLES WERE DETECTED. THEREFORE, THE COMPLAINT WAS NOT DUPLICATED, AND IT COULD NOT BE CONFIRMED. THE HEMOSTATIC VALVE LEAK ISSUE REPORTED BY THE CUSTOMER COULD NOT BE REPLICATED DURING THE PRODUCT INVESTIGATION; OTHER ISSUES OR CIRCUMSTANCES MAY HAVE OCCURRED DURING THE USAGE OF THE DEVICE THAT COMPROMISED ITS PERFORMANCE. THE INSTRUCTIONS FOR USE (IFU) CONTAIN THE FOLLOWING WARNING: BEFORE INSERTING THE SHEATH INTO THE PATIENT, FLUSH THE SHEATH AND DILATOR WITH HEPARINIZED NORMAL SALINE TO REMOVE AIR BUBBLES AND ANY POTENTIAL PARTICULATE. AFTER THE SHEATH IS IN THE LEFT ATRIUM OF THE PATIENT, MAINTAIN A CONSTANT FLOW OF HEPARINIZED NORMAL SALINE TO THE SHEATH TO MINIMIZE THE RISK OF AIR EMBOLI. AS PART OF BIOSENSE WEBSTER¿S QUALITY PROCESS, ALL DEVICES ARE MANUFACTURED, INSPECTED, AND RELEASED TO APPROVED SPECIFICATIONS. IF ADDITIONAL INFORMATION IS RECEIVED REGARDING THIS EVENT, A SUPPLEMENTAL 3500A REPORT WILL BE SUBMITTED TO THE FDA. MANUFACTURER'S REF. # (B)(4).
IT WAS REPORTED THAT A PATIENT UNDERWENT A SUPRAVENTRICULAR TACHYCARDIA ABLATION PROCEDURE WITH A CARTO VIZIGO¿ 8.5F BI-DIRECTIONAL GUIDING SHEATH - SMALL AND WHEN FLUSHING THE SHEATH, FLUID (SALINE SOLUTION) ESCAPED FROM THE THREE-WAY STOPCOCK. THE ISSUE WAS NOTED AT THE HUB AREA. HOWEVER, THERE WAS NO HEMOSTATIC VALVE/BRIM CAP/HUB DAMAGE NOTED. THERE WAS NO BLOOD RETURN IDENTIFIED. A SECOND DEVICE WAS USED TO COMPLETE THE OPERATION. THERE WAS NO ADVERSE EVENT REPORTED ON PATIENT.
Devices
| Seq | Brand | Generic | Product Code | Manufacturer | Model | Lot | UDI-DI |
|---|---|---|---|---|---|---|---|
| 942091 | CARTO VIZIGO¿ 8.5F BI-DIRECTIONAL GUIDING SHEATH - SMALL | INTRODUCER, CATHETER | DYB | BIOSENSE WEBSTER INC | 00002475 | 10846835016253 |
Patients
| Seq | Age | Sex | Outcome | Treatment |
|---|---|---|---|---|
| 1 | NA | Unknown |