FDA Adverse Event Malfunction Summary report: N

TALENT TAA STENT GRAFT

MDR report key: 19134011 · Received April 18, 2024

Report

Report Number
9612164-2024-01871
Event Type
Malfunction
Date Received
April 18, 2024
Date of Event
September 8, 2023
Report Date
April 18, 2024
Manufacturer
MEDTRONIC IRELAND
Product Code
MIH
PMA / PMN Number
P070007
Product Problem
Yes
Report Source
Manufacturer report
Reporter Location
CH
Reporter Occupation
PHYSICIAN
Health Professional
Yes

Narratives

Additional Manufacturer Narrative · 0

MEDTRONIC RECEIVED THE FOLLOWING INFORMATION FROM A JOURNAL  ARTICLE ENTITLED: COMPARISON OF CHIMNEY AND FENESTRATED TECHNIQUES FOR SUPRAAORTIC BRANCH REVASCULARIZATION DURING THORACIC ENDOVASCULAR AORTIC REPAIR: A SYSTEMATIC REVIEW AND META-ANALYSIS MINGYU LIU , XINYI WU ,  SONG WU,  XINYANG LI , SHIJIE XIN,  JIAN ZHANG CARDIOVASCULAR  INTERVENTIONAL  RADIOLOGY  (2023) 46:1315¿1328 HTTPS://DOI.ORG/10.1007/S00270-023-03537-4 MEDTRONIC SUBMITS THIS REPORT TO COMPLY WITH FDA REGULATIONS 21 CFR PARTS 4 AND 803. MEDTRONIC HAS MADE REASONABLE EFFORTS TO PROVIDE AS MUCH RELEVANT INFORMATION AS IS AVAILABLE TO THE COMPANY AS OF THE SUBMISSION DATE OF THIS REPORT. THIS REPORT DOES NOT CONSTITUTE AN ADMISSION OR A CONCLUSION BY FDA, MEDTRONIC, OR ITS EMPLOYEES THAT THE DEVICE, MEDTRONIC, OR ITS EMPLOYEE CAUSED OR CONTRIBUTED TO THE EVENT DESCRIBED IN THE REPORT. ANY REQUIRED FIELDS THAT ARE UNPOPULATED ARE BLANK BECAUSE THE INFORMATION IS CURRENTLY UNKNOWN OR UNAVAILABLE. MEDTRONIC WILL SUBMIT A SUPPLEMENTAL REPORT IF ADDITIONAL RELEVANT INFORMATION BECOMES KNOWN.

Description of Event or Problem · 0

TALENT AND VALIANT STENT GRAFTS WERE IMPLANTED IN THORACIC ENDOVASCULAR AORTIC REPAIRS ON UNKNOWN DATES OVER A 22 YEAR PERIOD .  153 STUDIES WERE INCLUDED IN THIS SYSTEMATIC REVIEW.  THE PATIENTS IN THE STUDIES UNDERWENT EITHER FENESTRATED THORACIC ENDOVASCULAR AORTIC REPAIR (FTEVAR) OR CHIMNEY THORACIC ENDOVASCULAR AORTIC REPAIR ( CH-EVAR) OF AORTIC DISEASE. THE FOLLOWING MALFUNCTIONS WERE REPORTED:  TYPE IA ENDOLEAK, MIGRATION, DEFORMATION IN VIVO  THE FOLLOWING ADVERSE EVENTS WERE REPORTED;  STROKE, OCCLUSION  PATIENT MORTALITY WAS REPORTED BUT THERE IS NO CAUSAL LINK THAT A MDT STENT GRAFT CAUSED OR CONTRIBUTED TO ANY DEATH.

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
2284601 TALENT TAA STENT GRAFT SYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TR MIH MEDTRONIC IRELAND UNK-CV-SR-TAL TAA

Patients

Seq Age Sex Outcome Treatment
1 59 YR Unknown