ONE STEP BUTTON¿
Report
- Report Number
- 3005099803-2010-04833
- Event Type
- Malfunction
- Date Received
- December 2, 2010
- Date of Event
- November 8, 2010
- Report Date
- November 9, 2010
- Manufacturer
- BOSTON SCIENTIFIC - SPENCER
- Product Code
- KGC
- PMA / PMN Number
- K910584
- Product Problem
- Yes
- Report Source
- Manufacturer report
- Reporter Occupation
- PHYSICIAN
Narratives
THE DEVICE HAS BEEN RECEIVED FOR ANALYSIS. UPON RECEIPT AND COMPLETION OF THE FAILURE ANALYSIS OF THE COMPLAINT DEVICE, IF THERE IS ANY FURTHER RELEVANT INFORMATION FROM THAT REVIEW, A SUPPLEMENTAL MEDWATCH WILL BE FILED.
THE PULLWIRE WAS THREADED THROUGH PERCUTANEOUS STOMA MEASURING DEVICE (PSMD) AND ATTACHED ONTO ONE STEP DELIVERY SYSTEM WIRE LOOP. A VISUAL EXAMINATION OF THE DEVICE REVEALED THE BLUE NYLON COATING OF THE PULLWIRE HAD BEEN PEELED AT THE INTERFACE BETWEEN THE PULLWIRE AND DELIVERY SYSTEM WIRE LOOP. THE NYLON COATING OF THE PULLWIRE WAS PEELED DOWN TO WIRE IN MULTIPLE AREAS AND REMAINED ATTACHED. NO REMNANTS OF THE PEELED NYLON COATING WERE RETURNED. THE RETURNED UNIT WAS CONSISTENT WITH THE COMPLAINT INCIDENT THAT THE DEVICE PULLWIRE COATING PEELED. THE EDGE OF THE PSMD HAS BEEN DETERMINED TO BE TOO SHARP THUS CATCHING ON THE NYLON COATING OF THE PULLWIRE AND CAUSING THE COATING TO PEEL AS THE PULLWIRE IS PULLED BACK THROUGH THE PSMD. THE DESIGN OF THE PSMD HAS BEEN DETERMINED TO BE THE MOST PROBABLE ROOT CAUSE OF THE FAILURE. FURTHER INVESTIGATION IS ONGOING. A REVIEW OF THE DEVICE HISTORY RECORD WAS PERFORMED AND REVEALED NO ISSUES RELATED TO THIS COMPLAINT.
IT WAS REPORTED TO BOSTON SCIENTIFIC CORPORATION THAT A ONE STEP BUTTON INITIAL PLACEMENT GASTROSTOMY KIT WAS USED DURING A PERCUTANEOUS ENDOSCOPIC GASTROSTOMY PROCEDURE PERFORMED ON (B)(6) 2010. ACCORDING TO THE COMPLAINANT, DURING THE PROCEDURE, WHEN THE PHYSICIAN REMOVED THE PULLWIRE AND PERCUTANEOUS MEASURING DEVICE, FROM THE PATIENT'S STOMA SITE, IT WAS NOTED THE COATING FROM THE PULLWIRE WAS ON THE STOMA SITE. THE PHYSICIAN RETRIEVED THE RESIDUE FROM THE OUTSIDE OF THE STOMA. THERE WAS NO RESIDUE INSIDE THE BODY. THE PROCEDURE WAS COMPLETED WITH THIS DEVICE. THERE WERE NO PATIENT COMPLICATIONS REPORTED AS A RESULT OF THIS EVENT. THE PATIENT'S CONDITION AT THE CONCLUSION OF THE PROCEDURE WAS REPORTED TO BE GOOD.
IT WAS REPORTED TO BOSTON SCIENTIFIC CORPORATION THAT A ONE STEP BUTTON INITIAL PLACEMENT GASTROSTOMY KIT WAS USED DURING A PERCUTANEOUS ENDOSCOPIC GASTROSTOMY PROCEDURE PERFORMED ON (B)(6), 2010. ACCORDING TO THE COMPLAINANT, DURING THE PROCEDURE, WHEN THE PHYSICIAN REMOVED THE PULLWIRE AND PERCUTANEOUS MEASURING DEVICE, FROM THE PATIENT'S STOMA SITE, IT WAS NOTED THE COATING FROM THE PULLWIRE WAS ON THE STOMA SITE. THE PHYSICIAN RETRIEVED THE RESIDUE FROM THE OUTSIDE OF THE STOMA. THERE WAS NO RESIDUE INSIDE THE BODY. THE PROCEDURE WAS COMPLETED WITH THIS DEVICE. THERE WERE NO PATIENT COMPLICATIONS REPORTED AS A RESULT OF THIS EVENT. THE PATIENT'S CONDITION AT THE CONCLUSION OF THE PROCEDURE WAS REPORTED TO BE GOOD.
Devices
| Seq | Brand | Generic | Product Code | Manufacturer | Model | Lot | UDI-DI |
|---|---|---|---|---|---|---|---|
| 1 | ONE STEP BUTTON¿ | TUBE, GASTRO-ENTEROSTOMY | KGC | BOSTON SCIENTIFIC - SPENCER | M00568520 | 13810538 |