FDA Adverse Event Injury Summary report: N

PERCLOSE PROGLIDE 6F SUTURE MEDIATED CLOSURE (SMC) SYSTEM

MDR report key: 1912053 · Received December 1, 2010

Report

Report Number
2953144-2010-03050
Event Type
Injury
Date Received
December 1, 2010
Date of Event
November 8, 2010
Report Date
November 10, 2010
Manufacturer
AV-REDWOOD CITY
Product Code
MGB
PMA / PMN Number
P960043
Adverse Event
Yes
Product Problem
Yes
Report Source
Manufacturer report
Reporter Location
CA, US
Reporter Occupation
HEALTH PROFESSIONAL

Narratives

Additional Manufacturer Narrative · 1

IT WAS INITIALLY REPORTED THAT THE DEVICE WOULD BE RETURNED FOR ANALYSIS. SUBSEQUENT INFORMATION REVEALED THAT THE DEVICE IS NOT AVAILABLE FOR EVALUATION. THE LOT NUMBER WAS NOT IDENTIFIED; THEREFORE, A DEVICE HISTORY RECORD REVIEW COULD NOT BE PERFORMED.(B)(4).

Additional Manufacturer Narrative · 1

(B)(4). THE DEVICE IS EXPECTED TO BE RETURNED FOR EVALUATION. IT HAS NOT YET BEEN RECEIVED. (B)(4) - MORBID OBESITY. (B)(4): DURING PROCESSING OF THIS COMPLAINT, ATTEMPTS WERE MADE TO OBTAIN COMPLETE EVENT, PATIENT AND DEVICE INFORMATION. DEVICE #1 - PROGLIDE (PART #12673-03; LOT #UNK), ARE BEING FILED UNDER A SEPARATE MEDWATCH MFR NUMBER.

Description of Event or Problem · 1

IT WAS REPORTED THAT A PHYSICIAN TRAINED IN THE USE OF THE STARCLOSE SE DEVICE ATTEMPTED ARTERIOTOMY CLOSURE OF THE COMMON FEMORAL ARTERY AFTER A DIAGNOSTIC PROCEDURE. REPORTEDLY, THE DEVICE COULD NOT BE INSERTED THROUGH THE SHEATH. THE STARCLOSE SE SYSTEM WAS REMOVED AND MANUAL COMPRESSION WAS USED TO ACHIEVE HEMOSTASIS. THERE WERE NO ADVERSE PATIENT EFFECTS REPORTED. NO ADDITIONAL INFORMATION WAS PROVIDED.

Description of Event or Problem · 1

IT WAS REPORTED THAT A PHYSICIAN TRAINED IN THE USE OF THE PROGLIDE DEVICE ATTEMPTED ARTERIOTOMY CLOSURE OF THE RIGHT COMMON FEMORAL ARTERY AFTER AN INTERVENTIONAL PROCEDURE. REPORTEDLY, A KINK WAS FOUND IN THE DISTAL END OF THE SHEATH. THE GUIDE WIRE WAS DIFFICULT TO ADVANCE INTO THE PROGLIDE AND AFTER CONTINUALLY TRYING TO ADVANCE THE GUIDE WIRE, THE GUIDE WIRE PUNCTURING A HOLE THROUGH THE SHEATH CREATING ITS OWN LUMEN. THE TIP OF THE PROGLIDE FOLDED BACK INTO THE PATIENT'S ILIAC, POSSIBLY BECAUSE OF STENOSIS. THE DEVICE WAS REMOVED AND A SECOND PROGLIDE DEVICE WAS USED; HOWEVER, HEMOSTASIS WAS NOT ACHIEVED. HEMOSTASIS WAS ACHIEVED USING MANUAL COMPRESSION FOR APPROXIMATELY 15 MINUTES. THERE WERE NO REPORTED ADVERSE PATIENT EFFECTS. THOUGH REQUESTED, NO ADDITIONAL INFORMATION WAS PROVIDED.

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
1 PERCLOSE PROGLIDE 6F SUTURE MEDIATED CLOSURE (SMC) SYSTEM SUTURE MEDIATED CLOSURE MGB AV-REDWOOD CITY

Patients

Seq Age Sex Outcome Treatment
1 Required Intervention DEVICE #1: PROGLIDE (PART #12673-03, LOT #UNK)