VICRYL POLYGLACTIN 910 SUTURE UNKNOWN PRODUCT
Report
- Report Number
- 2210968-2024-04075
- Event Type
- Injury
- Date Received
- April 9, 2024
- Date of Event
- June 1, 2022
- Report Date
- April 9, 2024
- Manufacturer
- ETHICON INC.
- Product Code
- GAM
- PMA / PMN Number
- K022269
- Adverse Event
- Yes
- Report Source
- Manufacturer report
- Reporter Location
- US
- Reporter Occupation
- OTHER
Narratives
PRODUCT COMPLAINT # (B)(4). THIS REPORT IS BEING SUBMITTED PURSUANT TO THE PROVISIONS OF 21 CFR, PART 803. THIS REPORT MAY BE BASED ON INFORMATION WHICH HAS NOT BEEN INVESTIGATED OR VERIFIED PRIOR TO THE REQUIRED REPORTING DATE. THIS REPORT DOES NOT REFLECT A CONCLUSION BY ETHICON INC, OR ITS EMPLOYEES THAT THE REPORT CONSTITUTES AN ADMISSION THAT THE PRODUCT, ETHICON INC, OR ITS EMPLOYEES CAUSED OR CONTRIBUTED TO THE POTENTIAL EVENT DESCRIBED IN THIS REPORT. IF INFORMATION IS OBTAINED THAT WAS NOT AVAILABLE FOR THE INITIAL REPORT, A FOLLOW-UP REPORT WILL BE FILED AS APPROPRIATE. AS NO CONTACT INFORMATION HAS BEEN PROVIDED, NO FOLLOW UP CAN OR WILL BE PERFORMED AT THIS TIME. THIS REPORT IS RELATED TO A JOURNAL ARTICLE; THEREFORE, NO PRODUCT WILL BE RETURNED FOR ANALYSIS AND THE BATCH HISTORY RECORDS CANNOT BE REVIEWED AS THE LOT NUMBER HAS NOT BEEN PROVIDED. H6 COMPONENT CODE: G07002 ¿ DEVICE NOT RETURNED. THE SINGLE COMPLAINT WAS REPORTED WITH MULTIPLE EVENTS. THERE ARE NO ADDITIONAL DETAILS REGARDING THE ADDITIONAL EVENTS. CITATION: INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE JUNE 2022, VOL.63, 3711 ¿ (B)(6).
TITLE: THE APPLICATION OF COLLAGEN MATRIX TO REVERSE HYPOTONY FOLLOWING TRABECULECTOMY WITH MITOMYCIN C. THE PURPOSE OF THE STUDY IS TO ASSESS THE ROLE OF COLLAGEN MATRIX IN REVERSING OCULAR HYPOTONY FOLLOWING TRABECULECTOMY. FROM (B)(6) 2019 TO (B)(6) 2021, 11 EYES OF 11 PATIENTS WHO REQUIRED SURGICAL REVISION DUE TO HYPOTONY FOLLOWING TRABECULECTOMY WERE INCLUDED IN THE STUDY. MEAN PATIENT AGE WAS 71.3±7.5 YEARS AND MEAN FOLLOW-UP DURATION WAS 110.8±78.6 DAYS (RANGE 22-247). DURING THE PROCEDURE, THE CONJUNCTIVA WAS HORIZONTALLY INCISED APPROXIMATELY 8-MM POSTERIOR TO THE LIMBUS. CONJUNCTIVA AND TENON WERE DISSECTED ANTERIORLY TO THE LIMBUS. THE COLLAGEN MATRIX WAS PLACED OVERLYING THE PRIOR TRABECULECTOMY SITE. THE INCISION WAS CLOSED USING AN 8-0 VICRYL (ETHICON) SUTURE IN A RUNNING FASHION. REPORTED COMPLICATIONS INCLUDED BLEB LEAK (N=3), AND PERSISTENT CORNEAL EDEMA (N=1). IN CONCLUSION, OUR INITIAL EXPERIENCE WITH COLLAGEN MATRIX SHOWS PROMISE AS AN EFFECTIVE METHOD OF REVERSING HYPOTONY WHILE MAINTAINING THERAPEUTIC IOP LEVELS. ADDITIONALLY, IT WAS ALSO EFFECTIVE IN REVERSING LEAKS ASSOCIATED WITH THIN-WALLED CYSTIC BLEBS WITHOUT THE NEED FOR ADDITIONAL TISSUE MANIPULATION. NO SURGICAL FAILURES WERE RECORDED. OUR FINDINGS ARE CONSISTENT WITH PREVIOUSLY PUBLISHED LITERATURE.
Devices
| Seq | Brand | Generic | Product Code | Manufacturer | Model | Lot | UDI-DI |
|---|---|---|---|---|---|---|---|
| 2270181 | VICRYL POLYGLACTIN 910 SUTURE UNKNOWN PRODUCT | SUTURE, ABSORBABLE, SYNTHETIC | GAM | ETHICON INC. |
Patients
| Seq | Age | Sex | Outcome | Treatment |
|---|---|---|---|---|
| 1 | NA | Unknown | Required Intervention |